| Product Type | Dehumidifier |
| Brand | GE |
| Model | ADEL50LZ |
| Capacity (Pints per Day) | 50 pints (at 80°F, 60% RH) |
| Dimensions (H x W x D) | 24.1 x 15.4 x 11.2 inches |
| Weight | 44.1 lbs |
| Power Supply | 115V / 60 Hz |
| Amperage | 5.0 A |
| Humidistat | Adjustable humidistat with auto shut-off |
| Drain Options | Continuous drain via hose; manual bucket (13.6 pints) |
| Fan Speeds | 2 speeds (Low/High) |
| Auto Restart | Yes, after power failure |
| Filter | Washable, reusable mesh filter |
| Filter Cleaning | Every 2 weeks; wash with water and mild detergent |
| Bucket Full Indicator | Yes, with auto shut-off when bucket full |
| Compressor Protection | 3-minute delay on restart |
| Operating Temperature Range | 41°F to 95°F |
| Energy Star Certified | Yes |
| Replacement Parts | Filter (WR87X10107), Bucket (WR87X10025) |
| Warranty | 1 year limited parts and labor |
Frequently Asked Questions - ADEL50LZ GE
How do I set the desired humidity level?
Press the Humidity Set button repeatedly to cycle through humidity levels from 35% to 85%. The digital display will show the selected set point. The unit will run until the humidity drops below the set level.
How often should I clean the filter?
Clean the washable filter every 2 weeks under normal operating conditions. Remove the filter from the back, rinse with lukewarm water, and let it dry completely before reinstalling. Do not operate without the filter.
Why is my dehumidifier not collecting water?
Common reasons: the humidity set point may be higher than room humidity, the room temperature is below 41°F, the filter is clogged, or the bucket is full. Check the display and ensure the unit is in a properly sized space.
Can I use a continuous drain hose?
Yes. Connect a standard garden hose (3/4 inch) to the drain outlet at the back. Run the hose to a floor drain or sump. Ensure the hose has no kinks and is lower than the drain outlet. The bucket can remain in place for overflow backup.
What does the 'Full' indicator mean?
The Full indicator lights and the unit shuts off automatically when the internal bucket is full. Empty the bucket and replace it securely. The unit will restart when the bucket is reinstalled correctly.
How do I reset the dehumidifier after a power outage?
The unit has auto restart feature. After power is restored, the unit will resume operation with the previous settings automatically. No manual reset is needed.
Why does the unit emit a clicking sound?
A clicking sound is normal when the compressor starts or stops. This is the relay engaging. If clicking is frequent or accompanied by rattling, check for loose parts or contact support.
What is the ideal location for the dehumidifier?
Place the unit in a closed room away from walls and furniture (at least 6 inches clearance). Avoid direct sunlight, near heat sources, or outdoor areas. Ensure the room temperature is between 41°F and 95°F.
How do I clean the exterior?
Unplug the unit. Wipe the cabinet with a soft damp cloth and mild detergent. Do not use abrasive cleaners or pour water directly onto the unit. Dry thoroughly before plugging in.
My unit shows an 'E' error code. What does it mean?
An 'E' code indicates a sensor or component failure. Common codes: E1 = humidity sensor error, E2 = freezing coil (defrost mode). Unplug and wait 10 minutes. If error persists, contact GE customer service.