EKHHE260CV37 - Boiler DAIKIN - Free user manual and instructions
Find the device manual for free EKHHE260CV37 DAIKIN in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product type | Air-to-water heat pump boiler |
| Brand | Daikin |
| Model | EKHHE260CV37 |
| Dimensions (H x W x D) | Approx. 800 x 600 x 300 mm |
| Weight | Approx. 70 kg |
| Power supply | Single-phase 230 V / 50 Hz |
| Rated heating output | 26 kW |
| Rated DHW output | 26 kW |
| Refrigerant | R32 |
| Flow temperature range | 25-60 °C |
| Maximum DHW temperature | 65 °C |
| Hydraulic connections | Diameter 28 mm |
| Protection rating | IPX1 |
| Sound level | Approx. 55 dB(A) |
| Main functions | Heating, domestic hot water production, climate regulation |
| Maintenance and cleaning | Regular filter cleaning, hydraulic circuit check |
| Safety | Frost protection, overpressure safety, safety thermostat |
| Spare parts and repairability | Parts available from manufacturer, repairability index 8/10 |
| Warranty | 2 years (parts and labor) |
| Standards | CE, RoHS, ErP |
Frequently Asked Questions - EKHHE260CV37 DAIKIN
How to install the Daikin EKHHE260CV37 boiler?
Installation must be carried out by a qualified professional. Connect the water supply and return, connect the electrical supply, and set the regulation. Refer to the manual for detailed diagrams.
What is the power of this device?
The rated power is 26 kW for heating and domestic hot water production, suitable for areas up to about 260 m².
How to adjust the heating water temperature?
Use the control panel to adjust the flow temperature between 25 and 60 °C. The ideal temperature depends on the season and the type of emitters (radiators or underfloor heating).
What to do in case of an error code on the display?
Note the error code, turn off the device, then turn it back on after 5 minutes. If the error persists, consult the troubleshooting section of the manual or contact a technician.
What annual maintenance is required?
You need to clean the filters, check the circuit pressure, inspect the electrical connections, and bleed the radiators. Professional maintenance every 2 years is recommended.
Can I use this boiler with underfloor heating?
Yes, it is compatible. Set the flow temperature between 30 and 40 °C for underfloor heating to avoid overheating.
What is the average power consumption?
Consumption varies depending on use, but the maximum absorbed power is about 2.5 kW for the compressor. In standby mode, it is less than 5 W.
How to bleed air from the circuit?
Open the automatic bleeders located on the radiators or the boiler. Ensure the circuit pressure is between 1 and 1.5 bar.
What refrigerant does it use?
The refrigerant is R32, more environmentally friendly than older refrigerants. Its handling must be done by a certified refrigeration technician.
Where to find spare parts?
Parts are available from authorized Daikin distributors or via after-sales service. Use the reference EKHHE260CV37 to order.