Product Type Digital Multimeter
Brand Peak
Model ZEN50
Category Measuring Equipment
Dimensions (H x W x D) 150 mm x 70 mm x 30 mm
Weight 200 g
Power Supply 2 x AAA batteries (1.5 V)
Display Type LCD, 3.5 digits
DC Voltage Range 200 mV to 600 V
AC Voltage Range 200 V to 600 V
DC Current Range 200 µA to 200 mA
Resistance Range 200 Ω to 20 MΩ
Continuity Test Yes, with buzzer
Diode Test Yes
Data Hold Yes
Auto Power Off Yes, after 15 minutes
Safety Rating CAT II 600 V
Operating Temperature 0°C to 40°C
Storage Temperature -10°C to 50°C
Humidity <80% RH
Accessories Included Test leads, manual, batteries
Maintenance & Cleaning Wipe with a dry cloth; no solvents
Spare Parts & Repairability Contact Peak service center; replace battery and fuses only
General Information Intended for indoor use; professional measuring device

Frequently Asked Questions - ZEN50 Peak

What is the Peak ZEN50?
The Peak ZEN50 is a digital multimeter used for measuring voltage, current, resistance, and continuity. It is suitable for basic electrical testing in households and light professional use.
How do I turn on the ZEN50?
Rotate the function switch from the OFF position to any measurement mode. The device will power on. To turn off, rotate the switch back to OFF. The auto power off feature will also shut it down after 15 minutes of inactivity.
What batteries does the ZEN50 use?
It requires two AAA 1.5V batteries. Open the battery compartment at the back, insert the batteries with correct polarity, and close the cover.
How do I measure DC voltage?
Set the function switch to the DC voltage range (V with straight line). Connect the black test lead to COM and red to V/Ω. Touch the probes to the circuit. Read the voltage on the display. Do not exceed 600V.
Can I measure AC current?
Yes, but only up to 200 mA. Set the function switch to the AC current range (A with wavy line). Connect the red lead to the A/µA/mA jack and black to COM. Ensure the circuit is broken and connect the meter in series.
What does the continuity test do?
The continuity test checks if two points are electrically connected. Set the switch to the �)) icon. Touch the probes together; you should hear a beep. Then test the circuit; a beep indicates continuity (resistance less than about 50Ω).
Is the ZEN50 safe for high voltage?
The ZEN50 has a CAT II 600V safety rating. It is safe for measuring on circuits directly connected to the mains outlet, but not for high-energy industrial environments. Always use proper test leads and follow safety guidelines.
How do I replace the fuse?
If the current measurement does not work, the fuse may be blown. Disconnect test leads, open the battery/fuse compartment, and replace the blown fuse with a 0.2A/250V fast-blow fuse (5x20mm). Do not use a different rating.
Why does the display show '1'?
A '1' on the left side of the display indicates an overload or the measured value is out of range. Switch to a higher range or check if the probes are connected correctly.
How do I clean the multimeter?
Switch off the device and remove test leads. Wipe the exterior with a soft, dry cloth. Do not use solvents, abrasives, or water. Keep the terminal jacks clean and dry.

User questions about ZEN50 Peak

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual ZEN50 - Peak and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ZEN50 by Peak.

USER MANUAL ZEN50 Peak

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Peak

Model : ZEN50

Category : Measuring equipment