| Product Type | Clamp Meter |
| Model | GT-900-CH |
| Brand | Beha-Amprobe |
| Dimensions (Approx.) | 240 x 80 x 45 mm |
| Weight (Approx.) | 300 g |
| Power Supply | 2 x 1.5V AA batteries |
| Display Type | Backlit LCD |
| Auto-Ranging | Yes |
| AC Voltage Range | 0.1 mV to 600 V |
| DC Voltage Range | 0.1 mV to 600 V |
| AC Current Range | 0.1 A to 400 A |
| Resistance Range | 0.1 Ω to 40 MΩ |
| Capacitance Range | 1 nF to 100 µF |
| Frequency Range | 10 Hz to 10 kHz |
| Temperature Measurement | -20°C to 1000°C (with thermocouple) |
| Data Hold | Yes |
| Safety Rating | CAT III 600V, CAT II 1000V |
| Maintenance | Clean with dry cloth; store in dry place |
| Spare Parts / Accessories | Test leads, batteries, holster, thermocouple |
| General Information | Auto-ranging clamp meter with backlit display and data hold |
Frequently Asked Questions - GT-900-CH Beha-Amprobe
How to replace the batteries in the Beha-Amprobe GT-900-CH?
Open the battery compartment on the back of the meter, remove the old batteries, and insert two new AA batteries observing polarity.
What is the maximum current that can be measured with the GT-900-CH?
The GT-900-CH can measure AC current up to 400 A.
How to use the data hold function?
Press the DATA HOLD button to freeze the reading on the display. Press again to release.
What safety precautions should be taken when using this clamp meter?
Always observe the safety ratings (CAT III 600V, CAT II 1000V). Use proper personal protective equipment and never exceed the rated voltage.
How to measure temperature with the GT-900-CH?
Connect a thermocouple (type K) to the input jacks, set the rotary switch to temperature mode, and read the value.
What is the accuracy of the AC voltage measurement?
Typical accuracy for AC voltage is ±(1.0% + 3 digits) for 50/60 Hz.
How to clean the GT-900-CH?
Wipe the exterior with a soft dry cloth. Do not use solvents or abrasive cleaners.
Does the GT-900-CH have a backlight?
Yes, the display has a backlight for use in low-light conditions.
What is the resistance measurement range?
The meter can measure resistance from 0.1 Ω to 40 MΩ.
Can the GT-900-CH measure DC current?
No, this model measures AC current only via the clamp.
User questions about GT-900-CH Beha-Amprobe
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.