Product Type Digital Oscilloscope
Bandwidth 200 MHz
Number of Channels 2
Sampling Rate 2 GSa/s (half channel), 1 GSa/s (all channels)
Memory Depth 14 Mpts (half channel), 7 Mpts (all channels)
Display 8-inch WVGA (800x480) TFT LCD
Dimensions (W x H x D) 400 x 200 x 113 mm
Weight 3.9 kg
Power Supply 100-240 VAC, 50-60 Hz, 45 W max
Main Functions Waveform capture, FFT analysis, 23 automatic measurements, serial bus triggering
Vertical Resolution 8 bits
Input Impedance 1 MΩ ± 1% || 15 pF ± 3 pF
Maximum Input Voltage 400 V (DC + AC peak) CAT I
Time Base Range 5 ns/div to 50 s/div
Maintenance and Cleaning Clean with a soft, dry cloth. Do not use solvents.
Safety Precautions Ground the instrument properly. Avoid moisture and explosive environments.
Spare Parts and Repairability Not user-serviceable. Contact authorized service center for repairs.
General Information USB, LAN, and GPIB interfaces supported. SCPI programmable.

Frequently Asked Questions - DS2202A Rigol

How do I turn on the Rigol DS2202A oscilloscope?
Press the Power button located on the front panel. The instrument will boot up and display the main screen.
How to connect a probe to the DS2202A?
Attach the probe BNC connector to one of the input channels (CH1 or CH2) and align the groove. Then connect the probe tip to the test point and the ground clip to a common ground.
What is the maximum input voltage for the DS2202A?
The maximum input voltage is 400 V (DC + AC peak) for CAT I environments. Never exceed this rating.
How do I perform an automatic measurement?
Press the Measure button, then select Auto Measure. Choose the desired parameter (e.g., frequency, amplitude) and the channel. The measurement will be displayed on screen.
Can I use the DS2202A with a PC?
Yes, connect via USB or LAN. Install the Rigol UltraSigma software to control the oscilloscope and transfer data.
How to update the firmware?
Download the latest firmware from Rigol's website. Save the file to a USB drive, insert it into the oscilloscope, go to Utility > Update and follow the on-screen instructions.
What does the 'Auto Scale' button do?
The Auto Scale button automatically adjusts the vertical, horizontal, and trigger settings to display the input signal optimally.
How do I save a waveform image?
Press the Save/Recall button, select File Type as BMP or PNG, choose a storage location (USB or internal), and press Save.
Is the DS2202A suitable for high-speed signals?
With a 200 MHz bandwidth and 2 GSa/s sampling rate, it can capture signals up to 200 MHz effectively.
How to perform an FFT analysis?
Press the Math button, select FFT, choose the source channel, and adjust the vertical scale and center frequency using the knobs.

User questions about DS2202A Rigol

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual DS2202A - Rigol and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DS2202A by Rigol.

USER MANUAL DS2202A Rigol

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Rigol

Model : DS2202A

Category : Measuring equipment