Product typeAir purifier
BrandPhilips
ModelAC1213
Dimensions (W x D x H)36 x 25 x 56 cm
Weight6.5 kg
Power supply220-240 V, 50 Hz
Power consumption30 W
Recommended room areaUp to 51 m²
CADR (Clean Air Delivery Rate)270 m³/h
Fan speed levels3 (plus auto mode)
Night modeYes, ultra quiet
TimerYes, 1 to 8 hours
Filter typeNanoProtect HEPA + activated carbon
Filter replacement indicatorYes
Noise level20 - 50 dB
Particle detectionPM2.5, air quality indicator
Auto modeYes, adjusts according to air quality
Child lockYes
Sensor maintenanceClean every 2 months
Filter replacementEvery 12 months (ref. FY0214)
SafetyAutomatic shut-off if tipped over
Warranty2 years

Frequently Asked Questions - AC1213 PHILIPS

How to install the filter initially?
Remove the packaging of the NanoProtect HEPA filter and insert it into the compartment at the back of the device. Close the cover and plug in the device.
How often should I replace the filter?
The filter should be replaced every 12 months or when the replacement indicator lights up. Use the Philips replacement filter FY0214.
How to clean the particle sensor?
Clean the sensor every 2 months with a dry cotton swab. Open the sensor flap at the back and gently wipe the lens.
Is the device noisy?
No, in night mode the noise level is only 20 dB, comparable to a whisper. At maximum speed it reaches 50 dB, similar to a quiet conversation.
What area can the AC1213 cover?
The device is designed to purify air in rooms up to 51 m² with a CADR of 270 m³/h.
Can I leave the device on all night?
Yes, night mode is specially designed for nighttime use: the lights turn off and the fan operates at low speed for quiet and energy-efficient operation.
What does the red light on the panel mean?
The red light indicates poor air quality (high particle concentration). The device will automatically switch to high speed to purify the air faster. Once the quality improves, the light will turn blue.
How to reset the filter indicator after replacement?
After changing the filter, press and hold the filter reset button (usually indicated by a key symbol) for 3 seconds until the indicator disappears.
Does the device consume a lot of electricity?
No, the maximum power consumption is 30 W, about 0.03 kWh. In standby mode it is nearly zero. It is very economical.
Can I wash the filter?
No, the NanoProtect HEPA filter cannot be washed. It must be replaced when saturated. However, the pre-filter (mesh) can be vacuumed occasionally.

User questions about AC1213 PHILIPS

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air purifier in PDF format for free! Find your manual AC1213 - PHILIPS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AC1213 by PHILIPS.

USER MANUAL AC1213 PHILIPS

AC12M: connected version 88 88 88 AC12B: non-connected version 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88

© 2019 Korea Pharma NV

on right interest

424121091383

Grid of 20 labeled diagrams showing various activities like reading, writing, and using a device with icons and labels.

Six-panel comic strip showing a person using a camera with labeled buttons and icons, including F0, R3, C7, and 21.

Contents

1 IMPORTANT SAFEGUARDS 2

2 Your air purifier 8 Product overview (Fig.①) 8 Controls overview (Fig.②) 8

3 Getting started 8 Installing the filters 8 Wi-Fi connection 9

4 Using the air purifier 10 Understanding the air quality light 10 Turning on and off 10 Changing the fan speed 11 Light sensor 11 Night sensing mode 11 Setting the child lock 12

5 Cleaning 13 Cleaning the body of the air purifier 13 Cleaning the air quality sensor 13 Cleaning the pre-filter 14

6 Replacing the filters 15 Filter replacement indicator 15 Replacing the filters 15 Filter reset 16

7 Storage 16

8 Troubleshooting 17
9 Warranty 20
10 Accessories 21
11 Disposal 21

Environmental friendly paper used. Thanks for your contribution to save trees.

1 IMPORTANT SAFEGUARDS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

  • Read all instructions before operating the air purifier.
  • Do not expose the air purifier to rain, or use near water, in a bathroom, laundry area or other damp location.
  • Do not use the air purifier where combustible gases or vapors are present.
  • Do not block the air inlet and outlet by placing items on the air outlet or in front of the air inlet. Do not insert fingers or foreign objects into the air outlet or air inlet.

  • Do not let water or any other liquid or flammable detergent enter the appliance to avoid electric shock and/or a fire hazard.

  • Do not clean the appliance with water, any other liquid, or a (flammable) detergent to avoid electric shock and/or a fire hazard.
  • Do not spray any flammable materials such as insecticides or fragrance around the appliance.
  • Check if the voltage indicated on the appliance corresponds to the local power voltage before you connect the appliance to the electrical outlet.
    • Always switch the air purifier OFF and unplug from the electrical outlet after using and before cleaning, moving and changing the filters. Be sure to remove the plug from the outlet. Never handle the power plug with wet or damp hands.

- Only use the power cord supplied with the air purifier.

- Keep the cord out of heavy traffic areas and arrange cord so that it will not be tripped over.

- Do not put the cord under carpets or throw rugs or near heat vents and open flames.

- Locate the air purifier near an electrical outlet and avoid using an extension cord.

- Do not use the plug in or near a power outlet that contains an electric air freshener to prevent damage to the plug.

- Do not use the air purifier outdoors. For indoor use only.

- If an extension cord must be used, exercise care.

- The marked electrical rating of the cord must be as great as the rating of the air purifier.

- Do not operate any air purifier with a damaged cord or plug. Discard air purifier or call 1-866-309-8817 for assistance.

- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.

- The cord should be arranged so that it will not drape over the edge of a counter or table where it could be pulled by children or tripped over unintentionally.

- Do not operate this appliance if it has a damaged power cord, plug or motor, if it is not working properly or after the appliance malfunctions or has been damaged in any manner. For assistance call 1-866-309-8817.

- Close supervision is necessary when the appliance is used by, on, or near children or invalids.

- This appliance is not a toy. Children should be supervised to ensure they do not play with the air purifier.

WARNING: To reduce the risk of fire or electric shock, do not use this air purifier with any solid-state speed control device.

This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and

(2) This device must accept any interference received, including interference that may cause undesired operation.

Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This product generates, uses, and can radiate radio frequency

energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this product does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and receiver.

- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

- Consult the dealer or an experienced radio/TV technician for help.

Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:

(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.

Caution

  • This appliance is not a substitute for proper ventilation, regular cleaning, or use of an exhaust fan or hood while cooking.
  • A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
  • Never use the air purifier unless it is fully assembled and with filters in place.
    • The air purifier must be used in its upright position.

- Make sure the air purifier is assembled/connected properly after cleaning the air quality sensor and pre-filter or replacing the filters.

- If the air purifier will not be used for a long period of time, unplug from the electrical outlet, clean the appliance, air quality sensor and pre-filter (see 'Cleaning') before storing.

• Make sure that you plug the appliance into a properly connected electrical outlet.

• Always place and use the appliance on a dry, stable, level, and horizontal surface. Make sure the air purifier cannot be easily knocked over by a person or object.

- Leave at least 20cm/8in free space behind and on both sides of the appliance and leave at least 30cm/12in free space above the appliance.

- Do not place anything on top of the appliance.

- Do not sit, stand or place heavy objects on the air purifier.

- Do not place the appliance directly below an air conditioner to prevent condensation from dripping onto the appliance.

• Make sure all filters are properly installed before you switch on the appliance.

- Only use the original Philips filters specially intended for this appliance. Do not use any other filters.

- Do not use the filter as fuel or for similar purposes.

- Avoid knocking against the appliance (the air inlet and outlet in particular) with hard objects.

• Always lift or move the appliance by the handle on back side of the appliance.

- NEVER tilt, move or attempt to change or replace a filter while the air purifier is operating. Switch OFF and unplug

from the electrical outlet. Do not move the air purifier by pulling on the power cord.

  • Do not use this appliance when using indoor smoke-type insect repellents or in places with oily residues, burning incense, or chemical fumes.
  • Do not use the appliance near gas appliances, heating devices or fireplaces.
  • Do not use the appliance in a room with major temperature changes, as this may cause condensation inside the appliance.
    • To prevent interference, place the appliance at least 2 meters/6 1/2 feet away from electrical appliances that use airborne radio waves such as TVs, radios, and radio-controlled clocks.
  • Use this air purifier for its intended household use as described in this manual. Do not use attachments not

recommended by Philips Electronics North America Corporation.

• The appliance does not remove carbon monoxide (CO) or radon (Rn). It cannot be used as a safety device in case of accidents with combustion processes and hazardous chemicals.
• Always wash your hands thoroughly after changing or cleaning a filter.
- Unplug the appliance to override smart enabled or remote functions.

SAVE THESE INSTRUCTIONS

This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT ATTEMPT TO DEFEAT THIS SAFETY FEATURE.

2 Your air purifier

Congratulations on your purchase, and welcome to Philips!

To fully benefit from the support that Philips offers, register your product at www.philips.com/welcome.

Product overview (Fig.①)

A Control panel
B Air quality light
C Air outlet
D Air quality sensor

NanoProtect True HEPA filter (EFY1410)

F NanoProtect Active Carbon filter (FY1413)

G Pre-filter

H Air inlet

I Front panel

Controls overview (Fig.②)

J On/Off button

K Night sensing mode button

L Display screen

M

For non-connected version: Indoor Allergen Index indicator

For connected version: Wi-Fi indicator

N Fan speed button

O Child lock button

3 Getting started

Installing the filters

PHILIPS AC1213 - Installing the filters - 1

Note

  • Make sure the air purifier is unplugged from the electrical outlet before installing the filters.
    • Make sure the side of the filter with the tag is pointing towards you.

1 Pull the bottom part of the front panel and gently lift to remove it from the air purifier (Fig.③).
2 Press the clip down (1) and pull the pre-filter towards you (2) (Fig.④).
3 Remove all filters (Fig.⑤).
4 Remove all packaging materials from the filters (Fig.6).
5 Place the thick HEPA filter (FY1410) into the air purifier and then the thin Active Carbon filter (FY1413) (Fig.⑦). The model numbers are shown on each filter.
6 Attach the pre-filter back into the air purifier (Fig.⑧).

PHILIPS AC1213 - Note - 1

Note

- Make sure the side with the clip is pointing towards you, and that all hooks of the pre-filter are properly attached to the purifier.

7 Reattach the front panel by pressing the top part of the panel onto the top of the air purifier (1). Then, gently push the panel against the body of the air purifier (2) (Fig.⑨).
8 Wash your hands thoroughly after installing filters.

Wi-Fi connection

Setting up the Wi-Fi connection for the first time

1 Download and install the 'Air Matters' App developed by FreshIdeas Studio from the App Store or Google Play.

PHILIPS AC1213 - Setting up the Wi-Fi connection for the first time - 1

2 Put the plug of the air purifier in the power socket and touch ⏻ to turn on the air purifier.
→The Wi-Fi indicator links orange for the first time.
3 Make sure that your smartphone or tablet is successfully connected to your Wi-Fi network.
4 Launch the "Air Matters" app and click on "Connect an Air Purifier or Monitor" on the top of the screen. Follow the onscreen instructions to connect the air purifier to your network.
5 After the successful pairing and connection, the Wi-Fi indicator will light up white. If pairing is not successful, consult the troubleshooting section, or the help section in the "Air Matters" App for extensive and up-to-date troubleshooting tips.

PHILIPS AC1213 - Setting up the Wi-Fi connection for the first time - 2

Note

  • This instruction is only valid when the air purifier is being set up for the first time. If the network has changed or the setup needs to be performed again, consult section "Reset the Wi-Fi connection" on page 9.
  • If you want to connect more than one air purifier to your smartphone or tablet, you have to do this one by one. Complete the set up of one air purifier before you turn on the other air purifier.
    • Make sure that the distance between your smartphone or tablet and the air purifier is less than 10 m without any obstructions.
  • This App supports the latest versions of Android and iOS. Please check www.philips.com/purifier-compatibility for the latest update of supported operating systems and devices.

Reset the Wi-Fi connection

PHILIPS AC1213 - Reset the Wi-Fi connection - 1

Note

• This applies when the default network to which your purifier is connected has changed.
- Reset the Wi-Fi connection when your default network has changed.

1 Put the plug of the air purifier in the power socket and touch ⬆ to turn on the air purifier.
2 Touch and simultaneously for 3 seconds until you hear a beep. →The air purifier goes to pairing mode.
→ The Wi-Fi indicator ↔ blinks orange.
3 Follow the steps 4-5 in "Setting up the Wi-Fi connection for the first time" section.

4 Using the air purifier

Understanding the air quality light

Indoor Allergen Index (IAI) is a real-time numerical display that provides visual and immediate feedback on indoor allergen level.

IAI Air quality light colorAir quality level
1-3 Blue Good
4-6 Blue-violet Fair
7-9 Red-purple Poor
10-12RedVery poor

The air quality light automatically goes on when the air purifier is switched on, and lights up all colors in sequence. After approximately 30 seconds, the air quality sensors select the color that corresponds to the surrounding air quality of airborne particles.

Turning on and off

PHILIPS AC1213 - Turning on and off - 1

Note

• Always place the air purifier on a stable, horizontal, and level surface with the front of the unit facing away from walls or furniture.
- For optimum purification performance, close doors and windows.
- Keep curtains away from the air inlet or air outlet.

1 Put the plug of the air purifier in the wall outlet.
2 Touch to switch on the air purifier (Fig.10).

→The air purifier beeps.

→The air purifier operates under the auto mode by default.

When the air purifier is warming up, "displays on the screen.

→After measuring the air quality for approximately 30 seconds, the air quality sensor automatically selects the appropriate air quality light color.

3 Touch and hold for 3 seconds to switch off the air purifier.

PHILIPS AC1213 - Note - 1

Note

  • If the air purifier stays connected to the electrical outlet after turning OFF, the air purifier will operate under the previous settings when turned ON again.
  • If the air purifier accidentally shuts off during running, it restarts automatically and operates under previous settings when the power supply is resumed.

Changing the fan speed

There are several fan speeds available. You can choose the auto mode, speed 1, 2, 3 or turbo mode (t).

Auto(A)

- Touch the fan speed button repeatedly to select the auto mode (Fig.11).

Allergen mode

The specially designed allergen mode can effectively reduce common allergens such as pollen and pet dander.

- Touch the fan speed button to select the Allergen mode (Fig.12). → Auto (A) and 📍 display on the screen.

Manual

- Touch the fan speed button repeatedly to select the fan speed you need (Fig.13).

Turbo (t)

In turbo mode, the air purifier operates on the highest speed.

- Touch the fan speed button to select the turbo mode (t) (Fig.14).

Light sensor

With the light sensor, the air purifier can work according to the ambient light.

When the ambient light dims for 10 seconds, all the lights on the control panel will turn off slowly. During this period, you can touch any of the buttons, all lights will turn on again. If you don't perform other operations within 10 seconds, all lights will turn off.

After the ambient light becomes bright and lasts at least for 10 seconds, all lights will turn on again.

Night sensing mode

You can activate the night sensing mode in two ways.

Activating the night sensing mode manually

  • Before you go to sleep, touch manually to activate the night sensing mode (Fig.15).
    →If the air quality light is blue, the air purifier directly goes to the night sensing mode. The air purifier operates quietly and the air quality light will be dimmed.
    If the air quality light is not blue, the air purifier operates under turbo mode for a maximum of 10 minutes, the air quality light blinks slow during this time, and then goes to the night sensing mode.

Auto activating the night sensing mode

When the air purifier operates in auto mode or allergen mode, if the light sensor detects the lights in your room are turned off, the air purifier goes to the night sensing mode automatically. The air purifier will adjust the fan speed in real-time to make sure the air in your room is good. The air quality light will be dimmed.

PHILIPS AC1213 - Auto activating the night sensing mode - 1

Note

• The light sensor detects the lights in your room after 11 hours in the night sensing mode.
- If the lights in your room are turned on, the air purifier will quit the night sensing mode and operate under the previous mode. The air quality light and the display will be on again.
• To exit the night sensing mode manually, touch or button.

Setting the child lock

1 Touch and hold the child lock button for 3 seconds to activate child lock (Fig.16).

→The child lock icon displays on the screen.
→When the child lock is on, all the other buttons are not responsive, only the child lock icon links.

2 Touch and hold the child lock button for 3 seconds again to deactivate child lock (Fig.17).

→The child lock icon disappears.

PHILIPS AC1213 - Setting the child lock - 1

Note

- The child lock function is automatically unlocked when the pre-filter cleaning code or the filter replacement code displays on the screen.

5 Cleaning

PHILIPS AC1213 - Cleaning - 1

Note

• Always turn the air purifier off and unplug the air purifier from the electrical outlet before cleaning.
- Never immerse the air purifier in water or any other liquid.
- Never use abrasive, aggressive, or flammable cleaning agents such as bleach or alcohol to clean any part of the air purifier.
- Only the pre-filter is washable. The air filter is not washable.
- Do not attempt to clean the filters or air quality sensor with a vacuum.

Cleaning the body of the air purifier

Regularly clean the inside and outside of the air purifier to prevent dust from collecting.

1 Use a soft, dry cloth to clean both the interior and exterior of the air purifier.
2 The air outlet can also be cleaned with a dry, soft cloth.
3 Detach the front cover from the air purifier and wash it under running tap water.

Cleaning the air quality sensor

Clean the air quality sensor every 2 months for optimal functioning of the purifier.

PHILIPS AC1213 - Cleaning the air quality sensor - 1

Note

  • If the air purifier is used in a dusty environment, it may need to be cleaned more often.
  • If the humidity level in the room is very high, condensation may develop on the air quality sensor and the air quality light may indicate a more poor air quality even though the air quality is actually good. If this occurs, clean the air quality sensor or use the air purifier on a manual speed setting.

1 Switch off the air purifier and unplug from the wall outlet.
2 Clean the air quality sensor inlet and outlet with a soft brush (Fig.18).
3 Remove the air quality sensor cover (Fig.19).
4 Clean the air quality sensor, the dust inlet and the dust outlet with a damp cotton swab (Fig.20).
5 Dry all parts thoroughly with a dry cotton swab.
6 Reattach the air quality sensor cover (Fig.21).

PHILIPS AC1213 - Note - 1

Note

• Always keep air quality cover closed while the air purifier is working.

Cleaning the pre-filter

Clean the pre-filter when F0 is displayed on the screen (Fig.22).

1 Switch off the air purifier and unplug from the wall outlet.
2 Pull the bottom part of the front panel and then gently lift to remove it from the air purifier (Fig.③).
3 Press the clip down (1) and pull the pre-filter towards you (2) (Fig.④).
4 If the pre-filter is very dirty, use a soft brush to brush away the dust. Then wash the pre-filter under running tap water (Fig.23).
5 Allow the pre-filter to air dry thoroughly before placing back in the air purifier.

PHILIPS AC1213 - Cleaning the pre-filter - 1

Note

  • To optimize the lifetime of the prefilter, make sure it dries completely after cleaning.
  • Wash your hands after handling the filter.

6 Put the pre-filter back into the air purifier (Fig.⑧).

PHILIPS AC1213 - Note - 1

Note

- Make sure the side with the clip is pointing towards you, and that all hooks of the pre-filter are properly attached to the air purifier.

7 To reattach the front panel, press the top part of the panel onto the top of the air purifier (1). Then, gently push the panel against the body of the air purifier (2) (Fig.⑨).

8 Put the plug of the air purifier in the wall outlet.
9 Touch and hold the 3 seconds to reset the pre-filter cleaning time (Fig.24).
10 Wash your hands thoroughly after installing filters.

6 Replacing the filters

Filter replacement indicator

This air purifier is equipped with a filter replacement indicator to make sure that the air purification filter is in optimal condition when the air purifier is operating. When the filters need to be replaced, the filter code displays on the screen.

If the filters are not replaced in 14 days, the air purifier will stop operating and automatically lock.

Replacing the filters

PHILIPS AC1213 - Replacing the filters - 1

Note

• The HEPA and Active Carbon filters are not washable or reusable.
• Always turn off the air purifier and unplug from the electrical outlet before replacing the filters.
- Do not clean the filter with a vacuum.
- If the pre-filter is damaged, worn or broken, do not use. Visit www.philips.com/support or call 1-866-309-8817 for assistance.

Filter alert light statusAction
A3 displays on the screenReplace NanoProtect True HEPA filter (FY1410)
C7 displays on the screenReplace NanoProtect Active Carbon filter (FY1413)
A3 and C7 display on the screen alternatelyReplace both filters

1 Turn off the air purifier and unplug from the wall outlet.
2 Take out the used air filter according to the filter alert light status displayed on the screen (Fig.25). Discard used filters.

PHILIPS AC1213 - Note - 1

Note

- Do not touch the pleated filter surface, or smell the filter as it has collected pollutants from the air.

3 Remove all packaging material from the new filter (Fig.6).
4 Place the new filters into the air purifier (Fig.⑦).
5 Put the plug of the air purifier in the wall outlet.
6 Touch and hold the 3 seconds to reset the filter lifetime counter (Fig.26).
7 Wash your hands after changing a filter.

PHILIPS AC1213 - Note - 1

Note

- This air purifier has no other user-serviceable parts. For assistance, call 1-866-309-8817.

Filter reset

You can replace filters even if there is no filter replacement code displayed on the screen. After replacing a filter, you need to reset the filter lifetime counter manually.

1 Touch and simultaneously for 3 seconds to enter the filter reset mode (fig.27).
Code (A3) of the NanoProtect True HEPA filter displays on the screen.
2 Touch and hold 📄 or 3 seconds to force reset the filter lifetime counter of the NanoProtect True HEPA filter (fig.②6).
3 Code (C7) of the Nanoprotect Active Carbon filter displays on the screen after the lifetime counter of the NanoProtect True HEPA filter has been reset (fig.28).
4 Touch and hold for 3 seconds to force reset the filter lifetime counter of the NanoProtect Active Carbon filter and exit the filter reset mode (fig.29).

7 Storage

1 Turn off the air purifier and unplug from the wall outlet.
2 Clean the air purifier, air quality sensor and pre-filter (see chapter 'Cleaning').
3 Let all parts dry thoroughly before storing.
4 Wrap the filter and pre-filter separately in air tight plastic bags.
5 Store the air purifier, the filter and pre-filter in a cool, dry location.
6 Always thoroughly wash hands after handling filters.

8 Troubleshooting

This chapter summarizes the most common problems you could encounter with the air purifier. If you are unable to solve the problem with the information below, visit www.philips.com/support or call 1-866-309-8817 for assistance.

Problem Possible solution

The air purifier does not work even though it is plugged in to the wall outlet and switched on.Try a different electrical outlet or check the wall switch.The filter alert status is displaying the filter code. Replace the corresponding filter and reset the filter lifetime counter (see chapter "Replacing the filter").If the problem persists, visit www.philips.com/support or call 1-866-309-8817 for assistance.
The air purifier does not work even though it is switched on.The filter replacement indicator has been on continuously but you have not replaced the corresponding filter, and the air purifier is now locked. In this case, replace the filter and reset the filter lifetime counter.
The air purifier accidentally powers off.The air purifier restarts automatically and goes to the previous mode when the power resumes.
How can I know whether my device is connected version or non-connected version?Please check the type plate at the backside of the device, model AC1214 is the connected version while model AC1213 is non-connected version.
The airflow that comes out of the air outlet is significantly weaker than before.The pre-filter is dirty. Clean the pre-filter (see chapter "Cleaning").
The air quality does not improve, even though the air purifier has been operating for a long time.One of the filters has not been placed in the air purifier or the filter is not placed properly. Make sure that all filters are properly installed in the following order, starting with the innermost filter:1) NanoProtect True HEPA filter (FY1410); 2) NanoProtect Active Carbon filter (FY1413) 3) pre-filter.The air quality sensor is wet. Make sure that the air quality sensor is clean and dry (see chapter "Cleaning").
Problem Possible solution
The color of the air quality light always stays the same.· The air quality sensor is dirty. Clean the air quality sensor (see chapter "Cleaning").
The air purifier produces a unpleasant smell.· The first few times you use the air purifier, it may produce a plastic smell. This is normal. The air purifier may also produce an unpleasant smell when the filter is dirty. In this case, clean or replace the appropriate filter.· If the air purifier produces a burnt odor, switch OFF and unplug from the electrical outlet. Call 1-866-309-8817 for assistance.
The air purifier is loud.· If the air purifier is too loud, change the fan speed to a lower fan speed level. When using the air purifier in a bedroom at night, choose the night sensing mode or select a lower fan speed level.
The air purifier still indicates that I need to replace a filter, but I already did.· Perhaps you did not reset the filter lifetime counter. Plug in the air purifier, touch to switch on the air purifier, and touch and hold the 3 seconds.
Error codes "E1", "E2", "E3" or "E4" displays on the screen.· The air purifier has malfunctions. Visit www.philips.com/support or call 1-866-309-8817 for assistance.

For AC1214 connected version only:

Problem Possible solution
Which App I should download?·Please download and install the 'Air Matters' App developed by FreshIdeas Studio from the App Store or Google Play.
The Wi-Fi setup is not successful.·If the router your purifier is connected to is dual - band and currently it is not connecting to a 2.4GHz network, please switch to another band of the same router (2.4GHz) and try to pair your purifier again. 5Ghz networks are not supported.·Web authentication networks are not supported.·Check if the purifier is within range of the Wi-Fi router. You can try to locate the air purifier closer to the Wi-Fi router.·Check if the network name is correct. The network name is case-sensitive.·Check if the Wi-Fi password is correct. The password is case-sensitive.·Retry the setup with the instructions in section 'Set up the Wi-Fi connection when the network has changed'.·The Wi-Fi connectivity can be interrupted by electromagnetic or other interferences. Keep the appliance away from other electronic devices that may cause interferences.·Check if the mobile device is in airplane mode. Make sure to have the airplane mode deactivated when connecting to the Wi-Fi network.·Consult the help section in the App for extensive and up-to-date troubleshooting tips.

9 Warranty

FULL TWO-YEAR WARRANTY

Philips Electronics North America Corporation warrants each new Philips product, Models AC1213/AC1214 (excluding filters), against defects in materials or workmanship for a period of two years from the date of purchase, and agrees to repair or replace any defective product without charge.

IMPORTANT: This warranty does not cover damage resulting from accident, misuse or abuse, lack of reasonable care, the affixing of any attachment not provided with the product or loss of parts or subjecting the product to any but the specified voltage.*

NO RESPONSIBILITY IS ASSUMED FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.

In order to obtain warranty service, simply go to www.philips.com/support or call 1-866-309-8817 for assistance. It is suggested that for your protection, you return shipments of product by insured mail, insurance prepaid. Damage occurring during shipment is not covered by this warranty.

NOTE: No other warranty, written or oral, is authorized by Philips Electronics North America Corporation. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion and limitations may not apply to you.

* Read enclosed instructions carefully.

In US Manufactured for:

Philips Personal Health

a division of Philips North America LLC

P.O. Box 10313

Stamford, CT 06904

United States of America

In Canada Imported for:

Philips Electronics LTD, 281 Hillmount

Road, Markham, Ontario L6C 2S3

PHILIPS and Philips Shield are

©2019 Philips North America LLC.

All rights reserved.

PHILIPS AC1213 - NO RESPONSIBILITY IS ASSUMED FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. - 1

This symbol on the product's nameplate means it is listed by Underwriters Laboratories, Inc.

App Store is a service mark of Apple Inc.

Google Play is a trademark of Google Inc.

"Air Matters" app developed by

FreshIdeas Studio.

PHILIPS AC1213 - NO RESPONSIBILITY IS ASSUMED FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. - 2

The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between the model's CADR for Dust and the

electrical energy it consumes, or CADR/Watt.

10 Accessories

Philips accessories may be purchased at a store near you, or on our website www.philips.com/store.

11 Disposal

Your product is designed and manufactured with high quality materials and components, which can be recycled and reused. For recycling information, please contact your local waste management facilities or visit www.recycle.philips.com

Contenu

1 RECOMMANDATIONS IMPORTANTES 23

1 RECOMMANDATIONS IMPORTANTES

VEUILLEZ LIRE CES INSTRUCTIONS DE SÉCURITÉ AVANT D'UTILISER LE PURIFICATEUR D'AIR ET CONSERVEZ-LES

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PHILIPS

Model : AC1213

Category : Air purifier