60.4510.01 - Weather Station TFA - Free user manual and instructions
Find the device manual for free 60.4510.01 TFA in PDF.
| Product type | Wireless weather station |
| Brand | TFA |
| Model | 60.4510.01 |
| Screen dimensions | Approximately 150 x 100 x 20 mm |
| Screen weight | Approximately 200 g |
| Screen power supply | 2 AAA batteries (not included) |
| Outdoor sensor power supply | 2 AA batteries (not included) |
| Transmission range | Up to 30 meters in open field |
| Radio frequency | 433 MHz |
| Indoor temperature | Measurement from 0°C to +50°C |
| Outdoor temperature | Measurement from -20°C to +60°C |
| Indoor humidity | 20% to 95% RH |
| Outdoor humidity | 20% to 95% RH |
| Atmospheric pressure | Display in hPa with trend |
| Weather forecast | Symbols: sunny, cloudy, rainy, etc. |
| Clock and alarm | Radio-controlled clock DCF77, alarm |
| Calendar | Display of day and date |
| Moon phase | Not available on this model |
| Maintenance and cleaning | Clean with a soft, dry cloth. Do not use chemical products. |
| Safety | Do not expose to excessive humidity or shocks. Keep out of reach of children. |
| Spare parts and repairability | Outdoor sensor available separately. Batteries replaceable by user. |
| General information | Backlit LCD screen, table stand and wall mount. |
Frequently Asked Questions - 60.4510.01 TFA
User questions about 60.4510.01 TFA
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Weather Station in PDF format for free! Find your manual 60.4510.01 - TFA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 60.4510.01 by TFA.
USER MANUAL 60.4510.01 TFA
Radio-controlled clock with outdoor and indoor temperature
GB
Thank you for choosing this instrument from TFA.
- Before you start using it
- Please make sure to read the instruction manual carefully.
This information will help you to familiarise yourself with your new device, to learn all of its functions and parts, to find out important details about its first use and how to operate it, and to get advice in the event of faults.
- Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use.
- We shall not be liable for any damage occurring as a result of non following of these instructions. Likewise, we take no responsibility for any incorrect readings and for any consequences which may result from them.
- Please take particular note of the safety advice!
- Please keep this instruction manual for future reference.
- Delivery contents
• Radio-controlled clock
• Outdoor transmitter (30.3210.10)
- Field of operation and all the benefits of your new instrument at a glance
• Highest precision radio-controlled clock
- Outdoor temperature via wireless outdoor transmitter (433 MHz), distance range of up to 100 m (free field)
- Indoor temperature
• Alarm with snooze function
• Weekday in 8 languages and date
- Manual setting option and time zone
• Temperature alarm
- Ideal for home, office, waiting room, lobby or entrance hall and as a gift
• For wall mounting or table standing
- For your safety
- This product is exclusively intended for the field of application described above. It should only be used as described within these instructions.
- Unauthorized repairs, modifications or changes to the product are prohibited.

Caution! Risk of injury:
- Keep these devices and the batteries out of reach of children.
- Batteries contain harmful acids and may be hazardous if swallowed. If a battery is swallowed, this can lead to serious internal burns and death within two hours. If you suspect a battery could have been swallowed or otherwise caught in the body, seek medical help immediately.
- Batteries must not be thrown into a fire, short-circuited, taken apart or recharged. Risk of explosion!
- Low batteries should be changed as soon as possible to prevent damage caused by leaking. Never use a combination of old and new batteries together, nor batteries of different types.
- Wear chemical-resistant protective gloves and safety glasses when handling leaking batteries.

Important information on product safety!
- Do not place your product near extreme temperatures, vibrations or shocks.
- Protect it from moisture.
Radio-controlled clock with outdoor and indoor temperature
- Elements and buttons
5.1 Radio-controlled clock
LCD Display(Fig. 1)
A1: Time signal symbol
A3: Time with seconds
A5: Date with weekday
Buttons front (Fig. 1)
B1: MODE button B2: SNOOZE button
B3: ALARM button
Buttons back (Fig. 2)
B4: +12/24 button
B6: SEARCH button
B8: ALERT button
Housing (Fig. 2)
C1: Wall mount holes C2: Stand (fold out)
C3: Battery compartment
5.2 Outdoor transmitter
Front (Fig. 1)
D1: LED signal lamp
Back (Fig. 2)
D3: Battery compartment
D5: Stand (fold out)
Inside the battery compartment:
RESET button °CI°F button
- Getting started
- Place the radio-controlled clock and the transmitter on a desk with a distance of approximately 1.5 meter. Avoid getting close to possible interference sources (Electronic devices and radio installations).
- Open the battery compartment of the radio-controlled clock and remove the battery insulation strip. All LCD segments will be displayed briefly. Close the battery compartment again.
• Pull the protective foil off the display.
- Open the battery compartment of the outdoor transmitter by extending the stand and pull the lid down. Insert 2 x 1,5 V AAA batteries, observing the correct polarity (see marking). All LCD segments will be displayed briefly. The signal lamp will be lighting briefly. The outdoor temperature will be displayed. Press the "C"F button inside the battery compartment of the transmitter to change between °C (Celsius) or °F (Fahrenheit) as temperature unit. Close the battery compartment again.
- The indoor temperature will be displayed on the radio-controlled clock and the radio-controlled clock will scan the outdoor temperature and the reception symbol will be flashing.
- If the outdoor temperature will not be displayed on the radio-controlled clock, “--” appears on the display. Check the batteries and try it again. Check if there is any source of interference.
- You can start the initialization manually. Press and hold the SEARCH button on the radio-controlled clock for three seconds. The radio-controlled clock will scan again the outdoor temperature. Press and hold RESET button in the battery compartment of the outdoor transmitter for three seconds.
- Radio-controlled time reception
- The clock will now scan the DCF frequency signal and the DCF symbol will be flashing. When the time code is received successfully after 5 minutes, the radio-controlled time, the date and the DCF symbol are displayed steadily in the display.

Radio-controlled clock with outdoor and indoor temperature

- If there is no reception possible, manual initialization can be helpful.
- Press and hold - 1 °CI°F button for three seconds.
• The DCF symbol will be flashing.
- Interrupt the reception by pressing the -ICIF button again for three seconds. The DCF symbol disappears.
- The DCF reception always take place at 3:00 o'clock in the morning. If the reception is not successfully received at 3:00 o'clock, it shall be held further attempts at 6:00 o'clock.
• There are three different reception symbols:
flashing - reception is active
↑ stays - reception is successful
No symbol - no reception / time is manually set
- If the clock cannot detect the DCF-signal (for example due to disturbances, transmitting distance, etc.), the time can be set manually. The DCF symbol disappears and the clock will then work as a normal quartz clock. (see: Manual setting of the clock and calendar).
7.1 Note for radio-controlled time DCF:
The time base for the radio-controlled time is a caesium atomic clock operated by the Physikalisch Technische Bundesanstalt Braunschweig. It has a time deviation of less than one second in one million years. The time is coded and transmitted from Mainflingen near Frankfurt via frequency signal DCF-77 (77.5 kHz) and has a transmitting range of approximately 1,500 km. Changeover from summer time or winter time is automatic. In Daylight Saving Time DST is shown on the LCD. The quality of the reception depends mainly on the geographic location. Normally there should be no reception problems within a 1,500 km radius around Frankfurt.
Please take note of the following:
- The recommended distance to any interfering sources like computer monitors or TV sets is at least 1.5-2 meters
- Inside ferro-concrete rooms (basements, superstructures), the received signal is naturally weakened.
In extreme cases, please place the unit close to a window to improve the reception.
- During nighttime, the atmospheric interference is usually less severe and reception is possible in most cases. A single daily reception is adequate to keep the accuracy deviation under 1 second.
- Operation
- During the reception of the outdoor temperature and the time is a button operation not possible.
- Press and hold + I 12/24 or - I °CI°F button in the setting mode for fast running.
- The instrument will automatically quit the setting mode if no button is pressed within 15 seconds.
8.1 Manual setting of the clock and calendar
- Press and hold MODE button for three seconds.
• The hour digit will be flashing
- Press the +1 12/24 or -1 °CI°F button to adjust hours.
- Press the MODE button again and the setting sequence is shown as follows: Minutes, seconds, year, date, month/day sequence (American version) or day/month (European version), month, day, the language of the day-of-the-week (default: GER) and time zone (default: 0) and adjust the settings with the °C/°F button or +1 12/24 button.
- Confirm the setting with the MODE button.
- Press the + I 12/24 button in normal mode to choose between 24- and 12 HR system (AM or PM appears on the display).
- The manually set time will be overwritten by the DCF time when the signal is received successfully.
Radio-controlled clock with outdoor and indoor temperature

8.1.1 Setting of the time zone
• In the setting mode you can make the time zone correction.
- The time zone correction is needed for countries where the DCF signal can be received but the time zone is different from the German time (e.g. +1=one hour later).
- Press the +1 12/24 or -1 °C/°F button.
- Confirm the setting with the MODE button.
8.1.2 Day-of-the week language
• In the setting mode you may change the setting of the day-of-the-week language: German (GER), French (FRA), Spanish (ESP), Italian (ITA), Dutch (NET), Danish (DAN), Russian (RU) and English (EN).
8.2 Setting of the alarm
- Press the MODE button in normal mode.
- AL and 7:00 (default) or the last adjusted alarm time appear on the display.
- Press and hold the MODE button.
• The hour digits will be flashing. - Press the + I 12/24 or - I °CI°F button to adjust the hours.
- Confirm the setting with the MODE button and set the minutes in the same way.
- Press the MODE button again to return to the current time.
• To activate the alarm function, press the ALARM button
• The alarm symbol appears on the display. - When the adjusted alarm time is reached, the alarm will ring.
• The alarm symbol will be flashing - Press any button and the alarm will stop working.
- If the alarm is not stopped manually, the increasing alarm will automatically turn off after certain minutes and will be reactivated at the same time.
- When the alarm rings, press the SNOOZE button and the snooze function will be activated.
- Once the snooze function is activated, Zz will be flashing on the display.
• The alarm will be interrupted for 5 minutes.
• The snooze function can be activated up to seven times.
• To turn off the alarm and snooze function press the ALARM button.
• The alarm symbol and the snooze symbol disappear on the display.
8.3 Setting of the temperature unit
- Press the -1°Cl°F button to change between ° C (Celsius) or ° F (Fahrenheit) as temperature unit.
8.4 Outdoor temperature alarm
- Press and hold the ALERT button for 3 seconds.
• ▲ and 50 °C (default) or the last adjusted upper temperature limit appear on the display. - Press the +1 12/24 or -1 °C/F button to adjust the upper temperature limit.
- Confirm with the ALERT button.
- and -20°C (default) or the last adjusted lower temperature limit appear on the display.
- Press the +1 12/24 or -1 °C/F button to adjust the desired lower temperature limit.
- Confirm with the ALERT button.
• The alarm is activated. On the display appears - Press the ALERT button again to deactivate the alarm function.
• disappears. - In the case of an alarm the corresponding symbol will be flashing and an alarm sound is activated.
- Press any button and the alarm will stop working.
9. Positioning and fixing of the radio-controlled clock and the outdoor transmitter
- Choose a shady and dry position for the outdoor transmitter. (Direct sunshine falsifies the measurement and continuous humidity strains the electronic components needlessly).
Radio-controlled clock with outdoor and indoor temperature

- Place the radio-controlled clock in the living room with the table stand (fold our). With the suspensions device you can fix it on a wall. Avoid the vicinity of any interfering field like computer monitors or TV sets and solid metal objects.
- Check the transmission of the signal from the outdoor transmitter to the radio-controlled clock (transmission range of up to 100 m free field). Within ferro-concrete rooms (basements, superstructures), the received signal is naturally weakened.
- If necessary choose another position for the outdoor transmitter and/or radio-controlled clock.
- If the transmission is successful, you can mount the outdoor transmitter.
10. Care and maintenance
- Clean the instruments with a soft damp cloth. Do not use solvents or scouring agents.
- Remove the batteries if you do not use the outdoor transmitter and the radio-controlled clock for a long period of time.
- Keep the instruments in a dry place.
10.1 Battery replacement
- As soon as the battery symbol appears on the display of the radio-controlled clock beside the outdoor temperature or in the display of the outdoor transmitter, change the batteries of the outdoor transmitter.
- Open the battery compartment of the outdoor transmitter by extending the stand and pull the lid down.
- Insert two new batteries 1.5 V AAA. Make sure the polarities are correct.
- Change the batteries when the functions of the radio-controlled clock becomes weak.
- Open the battery compartment of the radio-controlled clock.
- Insert four new batteries 1.5 V AA. Make sure the polarities are correct.
- Please note:
When the batteries are changed, the contact between outdoor transmitter and radio-controlled clock must be restored – so always insert new batteries into both devices or start a manual transmitter search.
11. Troubleshooting
Problems Solutions
| No indication on the display ofthe radio-controlled clock orthe outdoor transmitter | → | Ensure that the batteries polarity are correctChange the batteries |
No DCF reception
| → Press and hold - I °CI°F button for three seconds and start the initialization manually |
→ Wait for attempted reception during the night
→ Choose another place for your product
→ Manual setting of the clock
→ Check if there is any source of interference.
→ Restart the radio-controlled clock according to the manual
No reception of the → No outdoor transmitter is installed
outdoor transmitter → Check batteries of external transmitter
Display “--” (do not use rechargeable batteries!!)
→ Restart the transmitter and the radio-controlled clock according to the manual
Radio-controlled clock with outdoor and indoor temperature
GB
→ Start the manual search for the outdoor transmitter:
First press and hold the SEARCH button on the radio-controlled clock and then press the RESET button on the outdoor transmitter
→ Choose another place for the outdoor transmitter and/or the radio-controlled clock
→ Reduce the distance between the outdoor transmitter and the radio-controlled clock
→ Check if there is any source of interference.
Incorrect indication on → Change the batteries
both device
→ Radio-controlled clock: Use a pin to press the RESET button
Outdoor transmitter: Press the RESET button
If your device fails to work despite these measures contact the supplier from whom you purchased it.
12. Waste disposal
This product has been manufactured using high-grade materials and components which can be recycled and reused.
Never dispose of empty batteries and rechargeable batteries in household waste. As a consumer, you are legally required to take them to your retail store or to appropriate collection sites depending on national or local regulations in order to protect the environment. The symbols for the heavy metals contained are: Cd=cadmium, Hg=mercury, Pb=lead This instrument is labeled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE). Please do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compatible disposal.
13. Specifications
Radio-controlled cloc
Power consumption Batteries 4 x 1,5 V AA (not included)
Temperature range 0°C ... +50°C / +32°F... +122°F
Indication LL.L / HH.H Temperature is outside measuring range
Housing dimension 367 x 28 (86) x 235 mm
Weight 882 g ((instrument only)
Outdoor transmitter
Power consumption Batteries 2 x 1,5 V AAA (included)
Temperature range -20°C ... 50°C / -4 °F ... 122 °F
Indication LL.L / HH.H Temperature is outside measuring ranges
Radio-controlled clock with outdoor and indoor temperature
GB
Range max. 100 m (free field)
Transmission frequency 433 MHz
Maximum radio-frequency power < 10mW
Transmission time 64 seconds
Housing dimension 62 x 24 (35) x 101 mm
Weight 63 g (instrument only)
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the time of going to print and may change without prior notice.
The latest technical data and information about this product can be found in our homepage by simply entering the product number in the search box.
EU declaration of conformity
Hereby, TFA Dostmann declares that the radio equipment type 60.4510 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.tfa-dostmann.de/serviceidovinloadsite
www.tfa-dostmann.de
Cd = cadmium, Hg = mercure, Pb = plomb

Alimentation Piles 4 x 1,5 V AA (incluses)
Plage de mesure 0°C ... +50°C / +32 °F ... +122 °F