UFESA AC6201 - Vacuum Cleaner

AC6201 - Vacuum Cleaner UFESA - Free user manual and instructions

Find the device manual for free AC6201 UFESA in PDF.

📄 30 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice UFESA AC6201 - page 7
View the manual : Français FR English EN Español ES Magyar HU Português PT
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Canister vacuum cleaner
Brand Ufesa
Model AC6201
Maximum power 2000 W
Collection type Bagless (cyclonic)
Tank capacity 1.5 L
Filtration Washable HEPA
Operating range 8 m (5 m cable + tube)
Noise level 78 dB(A)
Dimensions (L x D x H) 25 x 30 x 40 cm
Weight 4.5 kg
Included accessories Main nozzle, crevice tool, upholstery tool, parquet brush
Hose Metal telescopic
Power adjustment Electronic on the body
Maintenance Washable HEPA filter (water), transparent dust cup to empty
Safety Thermal protection against overheating
Repairability Availability of spare parts (filters, brush, hoses)
Energy class A
Annual consumption 28 kWh
Country of origin China

Frequently Asked Questions - AC6201 UFESA

How to empty the dust container of the Ufesa AC6201 vacuum cleaner?
Press the release button on the container, remove it, open the lid over a trash can and empty the contents. For deep cleaning, you can wash the container with warm water and dry it completely before putting it back.
How to clean the HEPA filter?
Remove the HEPA filter located at the rear of the appliance. Tap it to remove dust or wash it with cold water (without detergent) and let it air dry for 24 hours. Never put it back wet.
What to do if the vacuum loses suction power?
Check that the container is not full, the filter is not clogged and that there is no blockage in the hose or brush. Clean the filter if necessary and clear any obstacles.
How to use the upholstery tool?
Attach the upholstery tool (soft bristle brush) to the end of the tube or hose. It is ideal for dusting fragile surfaces like shelves, curtains or cushions.
The power cord no longer retracts, what to do?
Make sure it is not twisted. If the mechanism is stuck, gently pull on the cord while pressing the retraction button. If the problem persists, contact customer service.
Can I use the vacuum without a bag?
Yes, the AC6201 model is bagless: it uses a cyclonic system that separates dust into a transparent container. No need to buy replacement bags.
The vacuum stops by itself during use, why?
This is probably due to thermal protection. The appliance automatically shuts off in case of overheating. Let it cool for 30 minutes, clean the filter and check that nothing is blocking the airflow.
What accessories are compatible with this model?
The included accessories are: a main brush, a crevice tool, an upholstery tool and a parquet brush. Other Ufesa accessories (turbo brush, etc.) may be compatible if the hose diameter is identical (35 mm).
How to maintain the main brush?
Remove the brush by pressing the side clip. Remove hair or threads wrapped around the brush using scissors or a comb. Wash the brush with water if necessary and let it dry before putting it back.
Where to find spare parts for the Ufesa AC6201 vacuum cleaner?
You can order spare parts (filters, brush, hose) directly from the Ufesa website or from authorized dealers. Check the manual for exact references.

User questions about AC6201 UFESA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Vacuum Cleaner in PDF format for free! Find your manual AC6201 - UFESA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AC6201 by UFESA.

USER MANUAL AC6201 UFESA

05 1 Chemicals and Coatings

(1) 2017年1月1日

[Unreadable]

C. 1986年10月25日(星期二)

[Unreadable]

UFESA AC6201 - 1

bagged vacuum cleaner

aspirader com saco

aspirateur avec sac

pursakos pursziv

الجربابع بسي

ufesa

UFESA AC6201 - ufesa - 1

natural_image White vacuum cleaner with black handle against red polka-dot background (no text or symbols)

www.ufesa.es

A
Exploded view diagram of a vacuum cleaner with numbered parts for identification and assembly reference.

B
UFESA AC6201 - ufesa - 3

UFESA AC6201 - ufesa - 4

UFESA AC6201 - ufesa - 5

D
UFESA AC6201 - ufesa - 6

E
UFESA AC6201 - ufesa - 7

UFESA AC6201 - ufesa - 8

©
UFESA AC6201 - ufesa - 9

UFESA AC6201 - ufesa - 10

F
UFESA AC6201 - ufesa - 11

UFESA AC6201 - ufesa - 12
ES

f rirodo clerw

Conductors, a copolymer, can be used to maintain the current state of 2015. Provoise the current state for the class of the materials. In the context of the supply of materials and the parts of the material of the materials that in the state is superconed on the first catalysts are superior to the other water sources. In every condition, we also use the solvent or solvent source. The solvent has been used to provide a

Congratulations on your choice of our appliance, and welcome among the users of ufesa products. In order to achieve best possible results we recommend using exclusively original ufesa accessories. They have been specially designed for this product. Please read this instruction manual carefully. Pay special attention to important safety instructions. Keep this User's Guide for future reference.

Important safety instructions

DANGER! / WARNING!

Health hazard

UFESA AC6201 - Health hazard - 1

- Do not operate the appliance if the cord, the housing or the handle is visibly damaged. In such a case, return the appliance to a service center.

- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

The appliance can only be repaired by qualified service personnel. Improper servicing may cause a serious hazard to the user. In case of defects please contact a qualified service center.

• Always unplug the appliance before cleaning, assembling or dismantling.

Turn off the device and unplug it from an outlet before replacing the equipment or approaching moving parts during use.

- Do not use the vacuum cleaner to clean people or animals, pay special attention to keep the nozzles away from eyes and ears.

Do not use the vacuum cleaner to clean liquids or other damp dirt.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

CAUTION!

Not observance can result in damage to possessions

UFESA AC6201 - Not observance can result in damage to possessions - 1

Connect the vacuum cleaner only to a 230 V mains supply equipped with a 16 A fuse.

Do not unplug by pulling on cord.

Do not run the vacuum cleaner or the brushes over the cord, it may cause damage to the cord insulation.

Do not vacuum without the SAFBAG dust bag module and the filters or if they are damaged. Do not pick up: matches, cigarette butts, hot ash.

Avoid picking up sharp objects.

Check the suction hose, the tubes and the nozzles – remove the dirt from the inside.

Do not vacuum fine dust such as: flour, cement, gypsum, toners for printers and copy machines etc. It is forbidden to cover up the air holes of the vacuum cleaner while it is working. Otherwise, the hot air has no way of exiting the vacuum cleaner, and this may lead to motor overheating causing a failure or a deformation of the plastic parts.

SUGGESTION Information on the product and suggestions for its use

UFESA AC6201 - SUGGESTION Information on the product and suggestions for its use - 1

The vacuum cleaner is for household use only. Operate the appliance only in indoor spaces and vacuum only dry surfaces. Before vacuuming dry the carpets that were wet cleaned. Vacuum cleaner is a universal device with a switchable sucking brush nozzle, which is used for vacuuming hard floors and carpets.

Technical parameters

The type of the vacuum cleaner and the technical parameters are indicated on the rating label. Mains protection 16 A.

Does not cause interferences with audio/video devices.

Does not require grounding ☐

Vacuum cleaners meet the requirements of the applicable norms.

The appliance is in conformity with the requirements of the directives:

–Electrical equipment designed for use within specific voltage limits (LVD) - 2006/95/EC.

-Electromagnetic compatibility (EMC) - 2004/108/EC.

The device meets the requirements of Commission Regulation (EU) No. 666/2013 on implementing the Directive of the European Parliament and of the Council 2009/125/EC with regard to eco-design requirements for vacuum cleaners.

The device complies with the requirements of the Commission Delegated Regulation (EU) No. 665/2013 supplementing Directive of the European Parliament and of the Council 2010/30/EU with regard to energy labelling of vacuum cleaners.

Noise level: 77 dB(A).

The appliance was marked by a CE sign on the rating label.

Static electricity

In the process of vacuuming of some surfaces in areas of low air humidity the device may become electrically charged. It is a natural phenomenon – it does not damage the device, and it is not considered to be a fault. In order to minimize the phenomenon, we recommend you to:

- discharge the device by touching metal items in the room with the pipe,

• increase air humidity in the room,
• use widely available antistatic agents.

Appliance elements

UFESA AC6201 - Appliance elements - 1

1 Accessory compartment cover
2 Combination brush fastening
3 Plug and cord
4 Cord rewind button
5 Outlet filter cover
6 Handle
7 ON/OFF button
8 Dust bag full indicator
9 Power decrease button
10 Suction power level indicator
11 Power increase button ⊕
12 Upper cover fastening
13 Suction hose
14 Telescopic suction tube
15 Outlet filter EPA E11 (installed in the vacuum cleaner)
16 Inlet filter (installed in the vacuum cleaner)
17 Inlet filter casing (installed in the vacuum cleaner)
18 SAFBAG dust bag module (with the installed SAFBAG dust bag)
19 Parquet brush "BNB"
20 Switch-over nozzle brush
21 Small nozzle
22 Crevice nozzle
23 Small brush

Preparing the vacuum cleaner for operation

UFESA AC6201 - Preparing the vacuum cleaner for operation - 1

1 Insert the curved hose end in the opening of the vacuum cleaner and gently press. A characteristic click indicates that the hose has been properly installed.
2 Connect the other end of the hose (handle) with the telescopic suction tube. In order to do so press the locking device "A" and slide the tube into the hose handle so that the locking device "A" is blocked in opening "B".
3 Adjust the length of the telescopic suction tube by sliding the slider according to the arrow and pull out/pull the tube together.
4 Assemble the appropriate nozzle or brush to the other end of the suction tube.

5 Use combination carpet & floor brush for vacuuming both hard surfaces and carpets. To clean hard surfaces – wooden floors, plastic floors, ceramic tiles etc. pull out the brush by pressing the switch on the combination brush according to the figure . Extract the brush when vacuuming carpets (set the switch in “”)
6 The vacuum cleaner is equipped with an accessory compartment. To open the compartment, lift the compartment lid and pull it downwards. 7 Grab the plug (3) and pull the cord out of the vacuum cleaner.

While pulling out the cord pay attention to the yellow stripe which signals the end of the cord. Further attempts (pulling on cord) may result in damaging the cord.

UFESA AC6201 - Preparing the vacuum cleaner for operation - 2

8 Plug in the appliance.

Before operation make sure that the SAFBAG dust bag module is installed in the vacuum cleaner chamber and that all filters are installed in the appliance.

9 Switch on the vacuum cleaner by pressing the "on/off" button (7).
10 The vacuum cleaner is equipped with an electronic power control which allows to gradually adjust the vacuum cleaner suction power during operation. To adjust the suction power use the power adjustment buttons (11,9) ⊕ to increase the suction power or ⊖ - to decrease the suction power. The suction power setting is indicated by the appropriate number of lit diodes.

The vacuum cleaner will by default begin operation at the medium power range. 4 diodes will light on the power level indicator (10).

The suction power may be adjusted during operation. The recommended settings are:

Setting 1 - vacuuming curtains Setting 2 - vacuuming upholstery Setting 3 - vacuuming carpets Setting 4 - vacuuming hard floors and crevices Setting 5 - maximum suction power.

The power may also be adjusted individually depending on the type of surface, vacuum effectiveness and suction power of the switchable combination brush.

11 Set the desired power value by pressing the power adjustment buttons + (11,9).

SAFBAG dust bag disassembly/assembly

UFESA AC6201 - SAFBAG dust bag disassembly/assembly - 1

Vacuum cleaner is equipped with SAFBAG bag (1 piece).

1 The vacuum cleaner is equipped with a dust bag full indicator (8). When the dust bag full indicator (8) lights during operation (with the nozzle or the brush lifted above the cleaned surface) it means that the bag is full and needs to be replaced. In addition the dust bag full indicator (8) may activate if the suction hose or the elements attached to the suction hose are clogged.
2 Switch off the vacuum cleaner by pressing the "on/off" button (7) and unplug the appliance.
3 Press the two side buttons on the end of the hose and remove the hose end from the inlet opening of the vacuum cleaner.
4 Release the upper cover fastening (12) and open the cover.
5 Remove the SAFBAG dust bag module (18) from the vacuum cleaner chamber.
6 Grab the dust bag cover, gently bend it towards the inside and remove the whole dust bag upwards.
7 Insert the plate of the new dust bag in the tracks of the SAFBAG dust bag module (18) and slide it until stop.
8 Slide the SAFBAG dust bag module together with the installed bag in the tracks located on the side of the vacuum cleaner chamber. Close the cover by pressing it until you hear a characteristic click – pay attention not to trap the dust bag.

Do not vacuum without the SAFBAG dust bag module installed in the appliance. The lack of the SAFBAG dust bag module prevents from locking the upper cover of the appliance.

UFESA AC6201 - SAFBAG dust bag disassembly/assembly - 2

It is recommended to replace the dust bag if:

a) the dust bag full indicator lights up,
b) the vacuum cleaner operates poorly,
c) the dust bag is full.

Filter disassembly

Before changing the filters make sure that the vacuum cleaner is switched off and unplugged from the mains supply.

EPA OUTLET FILTER

UFESA AC6201 - EPA OUTLET FILTER - 1

The vacuum cleaners are equipped with an E11 outlet filter EPA.

1 To replace the EPA filter lift the vacuum cleaner handle and open the accessory compartment.
2 Grab the filter cover by the fastening, firmly pull with the thumb and lift it upwards.
3 Remove the EPA filter case and replace it with a new one. The EPA filter ensures an effective operation of the vacuum cleaner for about 1 year.
4 Insert the cover so that the two protrusions in the lower part of the cover are inserted in the openings of the vacuum cleaner body, press the filter cover so that the rear fastenings snap shot on the body.

- Close the accessory compartment and lift down the handle.

INLET FILTER

UFESA AC6201 - INLET FILTER - 1

1 Release the upper cover fastening (12) and open the cover.
2 Remove the SAFBAG dust bag module (18) from the vacuum cleaner chamber.
3 Slide the inlet filter casing with the installed inlet filter from the tracks on the back side of the vacuum cleaner chamber.
4 Remove the inlet filter (16) from the inlet filter casing.
5 Place the new filter in the inlet filter casing (17) with the material side directed towards the inside of the casing.
6 Slide the inlet filter casing (17) together with the filter in the tracks until stop to the previous position.

Always replace a damaged inlet filter (16) with a brand new, original one.

UFESA AC6201 - INLET FILTER - 2

7 Insert the SAFBAG dust bag module to the vacuum cleaner chamber.
8 Close the cover by pressing it until you hear a characteristic click – pay attention not to trap the dust bag.

End of operation cleaning and maintenance

UFESA AC6201 - End of operation cleaning and maintenance - 1

1 Switch off the vacuum cleaner by pressing the "on/off" button (7).
2 Unplug the appliance.
3 Wind the cord by pressing the cord rewind button (4). While doing this hold the cord to make sure it

is not tangled and the plug does not hit the vacuum cleaner housing.

4 Disconnect the telescopic tube from the nozzle or brush.
5 Disconnect the telescopic tube from the hose. In order to remove the tube from the hose handle press the "A" locking device and pull the tube in the direction of the arrow.
6 Press the two side buttons on the end of the hose and remove the hose end from the inlet opening of the vacuum cleaner.
7 The vacuum cleaner may be stored vertically or horizontally. In order to do so, insert the fastening hook of the combination brush to the combination brush fastener. The hose may be attached to the vacuum cleaner, however you have to make sure that it is not excessively bent during storing.
8 If necessary wipe the housing and the dust bag container with a damp cloth (it may be soaked with dishwashing liquid) and dry it or wipe until dry.

Do not use abrasive detergents or solvents.

UFESA AC6201 - End of operation cleaning and maintenance - 2

Examples of problems while operating the vacuum cleaner

UFESA AC6201 - Examples of problems while operating the vacuum cleaner - 1

PROBLEM ACTION

A characteristic "fluttering" of the vacuum cleaner is heard.

  • Check the dust bag and the accessories, remove the cause of the clogging or replace the dust bag with a new one.
  • Clean the vacuum cleaner chamber and the filter.

The dust bag is damaged.

Remove the dust bag and the filters.

The electrical installation fuse went out.

Check if other appliances are not plugged to the same electrical circuit as the vacuum cleaner. If the fuse goes out repeatedly, return the vacuum cleaner to a service point.

The vacuum cleaner does not operate; the housing or the cord is damaged.

Return the vacuum cleaner to a service point.

PROBLEM ACTION

The suction power of the vacuum cleaner is weak.

Replace the dust bag and the filters, check the suction tube, the hose and the nozzle – remove the cause of the clogging.

Advice on disposal

UFESA AC6201 - Advice on disposal - 1

Our goods come in optimised packaging. This basically consists in using non-contaminating materials which should be handed over to the local waste disposal service as secondary raw materials.

UFESA AC6201 - Advice on disposal - 2

This product complies with EU Directive 2002/96/EC. The crossed wheelie bin symbol shown on the appliance indicates that when it comes to dispose of the product it must not be included in with household refuse. It must be taken to a special refuse collection point for electric and electronic appliances or returned to the distributor when purchasing a similar appliance. Under current refuse disposal regulations, users who fail to take discarded appliances to special refuse collection points may be penalised. Correct disposal of discarded appliances means that they can be recycled and processed ecologically, helping the environment and allowing materials used in the product to be reused. For more information on available waste disposal schemes contact your local refuse service or the shop where the product was purchased. Manufacturers and importers are responsible for ecological recycling, processing and disposal of products, whether directly or via a public system.

Your local town council can provide you with information about how to dispose of obsolete appliances.

The manufacturer/importer does not accept any liability for any damages resulting from unintended use or improper handling. The manufacturer/importer reserves his rights to modify the product any time in order to adjust it to law regulations, norms, directives, or due to construction, trade, aesthetic or other reasons, without notifying in advance.

Chers Clients!

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : UFESA

Model : AC6201

Category : Vacuum Cleaner