FR-291 - Fridge DAEWOO - Free user manual and instructions
Find the device manual for free FR-291 DAEWOO in PDF.
User questions about FR-291 DAEWOO
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Fridge in PDF format for free! Find your manual FR-291 - DAEWOO and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FR-291 by DAEWOO.
USER MANUAL FR-291 DAEWOO
: In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center
1. SPECIFICATION
1. MAJOR ACCESSORIES
| NAME Q'TY | ||
| FREEZER ROOM | ICING CASE 1 | |
| FREEZER SHELF 1 | ||
| FREEZER POCKET 2 | ||
| REFRIGERATOR ROOM | REF. SHELF 2 | |
| COVER VEGETB CASE 1 | ||
| VEGETABLE CASE 1 | ||
| EGG CASE 1 | ||
| EGG POCKET 1 | ||
| UTILITY POCKET 1 | ||
| JUMBO POCKET 1 | ||
| BOTTLE POCKET | 1 | |
2. QUALITY SPECIFICATION
| CLASIFICATION | CONTENTS | FR-291 | |
| CAPACITY (L) | GROSS | FREEZER | 73L |
| REFRIGERATOR | 173L | ||
| TOTAL | 246L | ||
| STORAGE | FREEZER | 62L | |
| REFRIGERATOR | 159L | ||
| TOTAL | 221L | ||
| EXTERNAL DIMENSION | WIDTH | 545 | |
| DEPTH | 584 | ||
| HEIGHT | 1620 | ||
| COOLING & CONTROL SYSTEM | DEFROST SYSTEM | FORCED | |
| DEFROST CONTROL | AUTOMATIC START & STOP | ||
| COMPRESSOR | YX58LHP5 | ||
| REFRIGERANT(g) | R-134a, 75 g | ||
| REFRIGERATOR DEGREE | *** | ||
| ELECTRIC CHARACTER | INPUT VOLTAGE | 220~240V | |
| COMPRESSOR | 0.6A | ||
| HEATER | 190W | ||
| ELECTRIC CONSUMPTION | 390 KWh/Year | ||
| WEIGHT | 53 Kg | ||
2. NAME OF FARTS

text_image
CASE ICING F SHELF F TEMP. CONTROL DIAL R TEMP. CONTROL DIAL WINDOW R SHELF COVER VECETB CASE VEGETB CASE R POCKET EGG POCKET ECG CASE UTILITY POCKET JUMBO POCKET BOTTLE POCKET3. AIR FLOW DIAGRAM

text_image
F POCKET 19°C -19°C 19°C 19°C 5~6°C 2~4°C 3~6°C 2~4°C 2~4°C 3~6°C 2~4°C 3~6°C 4~7°C R POCKET REFRIGERATOR ROOM VEGETB CASE4. REFRIGERANT CYCLE DIAGRAM

flowchart
graph TD
A["PIPE HOT"] --> B["PIPE *S PLT"]
B --> C["EVA"]
C --> D["PIPE SUC."]
D --> E["COMP"]
E --> F["PIPE CON(SUC)"]
F --> G["PIPE CON(DEL)"]
G --> H["CHARGE PIPE"]
H --> I["CAPE-TUBE"]
I --> J["DRYER AS"]
J --> K["COMPRESSOR"]
K --> L["PIPE CONN DEL"]
L --> M["PIPE *S PLT"]
M --> N["PIPE HOT"]
N --> O["DRYER AS"]
O --> P["CAPE-TUBE"]
P --> Q["PIPE CONN SUC."]
Q --> R["PIPE SUC"]
R --> S["EVAPORATOR"]
5. MACHINE ROOM VIEW AND PART LIST

text_image
Technical diagram of a vehicle interior with numbered components for identification| NO | PART NAME | PART CODE | Q'TY | MATERIAL | SPEC. | REMARKS |
| 1 | BASE COMP SAS | 3010342100 | 1 | O1, T1.0 | ||
| 2 | ABSORGLR COMP | 3010103400 | 4 | NR | H=40 | |
| 3 | COMPRESSOR | 3956146740 | 1 | JX46LCP4 | ---- | |
| 4 | SPECIAL WASHER | 4019H09030 | 2 | SK-5 T0.8 | ||
| 5 | SWITCH P-RELAY AS | 3018128900 | 1 | |||
| 6 | CLAMP BAND RELAY | 3816100110 | 1 | SK-5 T0.7 | T0.7 7N-3-A | |
| 7 | COVER RELAY | 3811400503 | 1 | |||
| 8 | PIPE CONN DEL | 3014417910 | 1 | DCUT1-O | 4.76 × 10.7 × 1.200 | |
| 9 | PIPE HOT | 3014462900 | 1 | TSW | 4 × 10.5 × 16434 | |
| 10 | PIPE *S PLT | 3014462700 | 1 | TSW | 4.76 × 10.7 × 15914 | |
| 11 | PIPE SUC AS | 3014463000 | 1 | — | ||
| 12 | DRYER AS | 3016808200 | 1 | XH-9 | 10g | |
| 13 | PIPE CONN SUC | 3014417910 | 1 | DCUT1-O | 6.0 × 10.5 × 1373 | |
| 14 | CORD POWER AS | 3011347000 | 1 | CP-2PIN | ||
| 15 | SCREW TAPPING | 7112401211 | 2 | MFZN | TITRS 4x12 | |
| 16 | SCREW MACHINE | 7002401065 | 1 | BSNI | TRS 4x10 | |
| 17 | WASHER TOOTHED | 7402204011 | 1 | MFZN | TE-B-4 | |
| 18 | CASE VAPORI | 3011187400 | 1 | PP | ||
| 19 | PIPE SERVICE | 4019L02020 | 1 | DCUT1-O | ||
| 20 | HOSE DRN A | 3013225100 | 1 | PP | ||
| 21 | CAP DRN HOSE B | 3010928000 | 1 | NBR | ||
| 22 | COVER HOUSING | 3001400400 | 1 | PP |
6. WIRE DIAGRAM & SOLID WIRE DIAGRAM
1) WIRE DIAGRAM

flowchart
graph TD
A["BLU"] --> B["FUSE TEMP."]
B --> C["BLU"]
C --> D["SKY BLU"]
D --> E["SKY BLU"]
E --> F["SLC"]
F --> G["R/C"]
G --> H["P-RELAY"]
H --> I["PTC 2 OL"]
I --> J["3"]
J --> K["BLU"]
K --> L["BRN BI-METAL"]
L --> M["BRN"]
M --> N["COMPRESSOR"]
N --> O["RED"]
O --> P["WHT BLU"]
P --> Q["Timer DEFROST RED"]
Q --> R["WHT BLU"]
R --> S["BRN"]
S --> T["SWITCH DR"]
T --> U["HTR C/BOX"]
U --> V["LAMP"]
V --> W["YEL"]
W --> X["BLU"]
X --> Y["GRN/YEL"]
Y --> Z["PLUG POWER"]
Z --> AA["BRN"]
AA --> AB["BRN"]
AB --> AC["SWITCH DR"]
AC --> AD["HTR-THERMO"]
AD --> AE["THERMOSTAT"]
AE --> AF["BRN SKY BLU"]
AF --> AG["BRN SKY BLU"]
2) SOLID WIRE DIAGRAM

flowchart
graph TD
A["Red"] --> B["F/W"]
B --> C["YEL"]
C --> D["SKY BLU"]
D --> E["BI-METAL BRN"]
E --> F["BRN"]
F --> G["WHT"]
G --> H["HTR DEFROST"]
H --> I["BLU"]
I --> J["BLU FUSE TEMP. BLU"]
J --> K["SWITCH DR"]
K --> L["YEL"]
L --> M["BLU"]
M --> N["HTR C/BOX BRN"]
N --> O["THERMOSTAT YEL"]
O --> P["SKY BLU"]
P --> Q["WHT BLU"]
Q --> R["LAMP BLU"]
R --> S["YEL"]
S --> T["WHT"]
T --> U["TIMER DEFROST BRN"]
U --> V["WHT BLU"]
V --> W["P-RELAY"]
W --> X["RED"]
X --> Y["QL"]
Y --> Z["PTC"]
Z --> AA["YEL"]
AA --> AB["SKY BLU"]
AB --> AC["PLUG POWER"]
AC --> AD["BRN"]
AD --> AE["GRN/YEL"]
7. MAIN COMPONENTS
- COMPRESSOR
| FR - 291 | |
| MODEL | YX58LHP5 |
| STARTING TYPE RSCR | |
| VOLTAGE 230V / 50Hz | |
| MAIN COIL RESISTANCE | 19.4Ω |
| SUB COIL RESISTANCE | 25.6Ω |
- RELAY
| FR - 291 | ||
| MODEL | 4TM129SHBYY-52 | |
| PTC | RESISTANCE | 33Ω |
| MAX. VOLTAGE | 355V | |
| MAX. CURRENT | 6A | |
| OL CURRENT 3.5A | ||
- RUNNING CAPACITOR
| FR - 291 | |
| VOLTAGE | AC |
| RATED CAPACITY | 4 μF |
400V
- LAMP
| FR - 291 | |
| VOLTAGE | AC 240V / 15W |
5. POWER CORD
| FR-291 | |
| TYPE | 3x0.75 mm^2 |
| LENGTH | 1.80m |
6. TEMPERATURE FUSE
| FR - 291 | |
| VOLTAGE | 250V |
| CURRENT | 10A |
| WORKING TEMP. | 77 °C |
7. Bi-METAL
| FR - 291 | |
| MODEL PST - 3 | |
| OFF TEMP. | 12 ± 3 |
7. DEFROST TIMER
| FR - 291 | |
| MOEDL | CF-3001-21 |
| CYCLE TIME 12 HR | ± 10.8 MIN |
8. DEFROST HEATER
| FR - 291 | |
| RATING AC 230V / 190W | |
| RESISTANCE | 269 Ω |
- FAN MOTOR
| FR - 291 | |
| MODEL | DAI-6122-DESFD |
| TYPE | SHADED |
| RATING | 230V/50HZ |
| INPUT | 5.0W |
| POLE | 2 |
| RPM 2000 ± 150 rpm | |
POLE
POLE
- R-THERMOSTAT
| FR - 291 | |
| MODEL | GNF-175D-01F(1) |
| RATING | AC 25 |
| ON/OFF TEMP. | 2.5 ± 2.5 °C |
250V/60Hz
- DOOR SWITCH
| FR - 291 | |
| TYPE 1 BUTTON 2 PIN | |
| RATING | AC 2 |
| MODEL | WDS |
250V/0.5A
001C-01
- CONTL BOX HEATER
| FR - 291 | |
| RATING AC 220V / 4W | |
| RESISTANCE | 12100 Ω |

F ROOM

R ROOM

text_image
56 67 OPTION
text_image
Exploded view diagram of a refrigerator with numbered parts for identification

text_image
58 30 40
text_image
MECH ROOM 55 56 57 58 59 60 15 61 52 51 54 62 63 64| NO | PART CODE | PART NAME | Q'TY | REAMRK |
| 1 301 | 0815700 CABINET | URT AS 1 | ||
| 2 301 | 1755200 DOOR S/W AS 1 WDS001C-01 | |||
| 3 301 | 2924600 HINGE *T AS 1 | |||
| 4 301 | 6000301 SPECIAL BOLT 3 M5 x L14 | |||
| 5 300 | 1400000 COVER *T HI 1 PP | |||
| 6 301 | 2924500 HINGE *M AS 1 | |||
| 7 301 | 6004000 SPECIAL BOLT 2 M6 x L10 | |||
| 8 301 | 2924700 HINGE *U AS 1 | |||
| 9 765 | 0602511 BOLT HEX 2 M6 x L25 | |||
| 10 | 3012105300 FOOT ADJ AS 2 PP+INSERT | |||
| 11 | 3001400200 COVER FAN A 1 HIPS | |||
| 12 | 3013412000 KNOB F CONTL 1 HIPS-c | |||
| 13 | 4017Z42312 FAN 1 ABS ID3.17 ∅100 | |||
| 14 | 3001400600 COVER SCREW 2 HIPS | |||
| 15 | 7112401211 SCREW TAPPING 4 T1TRS 4x12 MFZN | |||
| 16 | 3018921800 LOUVER F 1 PP-c | |||
| 17 | 3015917200 MOTOR F AS 1 230V/50Hz | |||
| 18 | 3012024600 FIXTURE MOTOR A 1 PP | |||
| 19 | 7122401211 SCREW TAPPING 2 T2TRS 4x12 | |||
| 20 | 3017062000 EVA SAS 1 | |||
| 21 | 3014120100 PAD EVA *L 1 F-PS | |||
| 22 | 3014120200 PAD EVA *R 1 F-PS | |||
| 23 | 3017202500 FUSE TEMP AS 1 105T,AC250V/10A | |||
| 24 | 3018128700 SWITCH BIMETAL 1 PST-3SW- | |||
| 25 | 4016N03280 CLAMP CABLE 3 NYLON-66, W3.6xL146 | |||
| 26 | 3012820200 HEATER SHEATH SAS 1 AC 220V, 175W | |||
| 27 | 3010549100 BOX CONTL 1 HIPS | |||
| 28 | 3013358100 INSU R DUCT *T 1 F-PS | |||
| 29 | 3013358200 INSU R DUCT *U 1 F-PS | |||
| 30 | 3018128310 SWITCH TIMER 1 220V/50Hz, 12HR | |||
| 31 | 3018304900 THERMOSTAT 1 | |||
| 32 | 3013412100 KNOB R CONTL 1 HIPS | |||
| 33 | 3017906700 SOCKET R LAMP AS 1 220V/15W | |||
| 34 | 7112401011 SCREW TAPPING 2 T1TRS 4x10 MFZN | |||
| 35 | 3015511000 | WINDOW R | 1 | GPPS |
| 36 | 3011187300 | CASE ICING | 1 | PP |
| 37 | 3017843700 | SHELF F | 1 | GPPS |
| 38 | 3017843600 | SHELF R | 2 | GPPS |
| 39 30 | 01400700 COVER VEGETB CASE 1 GPPS | |||
| 40 | 3011187600 | CASE VEGETB | 1 GPPS | |
| 41 | 3019027900 | POCKET F | 2 GPPS | |
| 42 30 | 12319500 GASKET F DR AS 1 PVC-S+MAGNET | |||
| 43 | 3011766900 | DOOR F URT AS | 1 | |
| 44 | 3011187200 | CASE EGG | 1 PP | |
| 45 | 3019027800 | POCKET EGG | 1 GPPS | |
| 46 | 3019028200 | POCKET UTILITY | 1 GPPS | |
| 47 | 3019028000 | POCKET JUMBO | 1 GPPS | |
| 48 | 3019028100 | POCKET R | 1 GPPS | |
| 49 30 | 12319600 GASKET R DR AS 1 PVC-S+MAGNET | |||
| 50 | 3011767000 | DOOR R URT AS | 1 | |
| 51 | 3956158K50 | COMPRESSOR | 1 | YX58LHP5 |
| 52 | 4019H09030 | SPECIAL WASHER | 2 | SK-5, T0.8 |
| 53 30 | 10103400 ABSORBER WASHER 4 NR H=40 | |||
| 54 30 | 10342100 BASE COMP SAS 1 GI, T1.0 | |||
| 55 | 3001400400 | COVER HOUSING | 1 HIPS(n) | |
| 56 | 3016404700 | CAPACITOR RUNNING | 1 400VAC, 4 μF, CLASS C | |
| 57 | 3816100110 | CLAMP BAND RELAY | 1 | |
| 58 30 | 18130300 SWITCH P RELAY AS 1 4TM 129SHBYY-52 | |||
| 59 | 3811400503 | COVER RELAY | 1 PP | |
| 60 | 3011348011 | CORD POWER AS | 1 | |
| 61 30 | 13225100 HOSE DRN A 1 PP | |||
| 62 | 3011187400 | CASE VAPORI | 1 PP | |
| 63 30 | 16808200 DRYER AS 1 XH-9, 10g | |||
| 64 | 3016003300 | SPECIAL BOLT | 2 M6.5x20 | |
| 65 | 7650601511 | BOLT HEX | 2 M6x15 | |
| 66 30 | 17843500 SHELF CHILLED CASE 1 GPPS | |||
| 67 | 3011112011 | CASE CHILLED | 1 | GPPS |
9. Methods of exchanging main parts.
1. F LOUVER PART
![]() | - Remove the screw cap, and unscrew the fixing screw(2EA). |
![]() | - Pull the louver forward, grasping at the fan cover and upper corner of louver. |
![]() | - Disassemble fan motor harness and remove Louver As.. |
![]() | - Unscrew the fixing screw at the back of louver(hidden under Al tape).- To remove the fan cover, pull the bottom of fan cover. |
2. EVAPORATOR PART
![]() | - Pull the suction pipe and capi. Tube forward, with care not to bend the pipes sharply. |
![]() | - Hold up evaporator and pull it forward. |
![]() | - Remove the evaporator pad. |
![]() | - To remove defrost heater, cut the clamp cable first, disassemble the harness then pull down the heater.- The assembling procedure of new heater is the reverse of disassemble steps. |

natural_image
Close-up of a hand inserting wires into a refrigerated appliance (no visible text or symbols)- To exchange the Bi-Metal, first cut the clamp cable then disassemble the harness.

natural_image
Close-up of hands installing a coiled electrical heating element in a refrigerated room (no visible text or symbols)- Extract the Temp. Fuse in the evaporator then disassemble the harness.
- The new Temp. Fuse should be located in the same position in the evaporator.
3. CONTROL BOX PART

natural_image
Hand inserting a plastic clip into a white refrigerator (no text or symbols visible)- To remove the temperature control dail, Pull it down.
![]() | - Unscrew the fixing screw(1EA). |
![]() | - Pull down the control box, then disassemble the harness. |
![]() | - Remove the lamp cover with screwdriver etc. pushing the front hooker part of the cover then lift up the cover. |
![]() | - Unscrew the fixing screw of the lamp socket. |

natural_image
Close-up of hands assembling or adjusting a small mechanical component on a white electronic device (no visible text or symbols)- Pull the lamp forward, then disassemble the connector.
- The assembling procedure of new lamp is the reverse of disassemble steps.
4. DOOR SWITCH PART

text_image
Person installing a label on a wall-mounted fixture, showing a green card with handwritten text and a tool.- In removing the door switch, push the door switch left, insert a pointed rods as screw-driver in the right gap, and push the rod left and pull the door switch forward.
- Be careful not to harm the surface of cabinet . (Use name plate etc. under the pointed rod)

natural_image
Close-up of hands installing or connecting wires on a wall-mounted appliance (no visible text or symbols)- Pull the door switch forward and remove the harness.

natural_image
Hand inserting a small white component into a door handle (no text or symbols visible)- In inserting new door switch, insert the left part of the switch in the hole then push the right part of refrigerator.