DAEWOO

FR-291 - Fridge DAEWOO - Free user manual and instructions

Find the device manual for free FR-291 DAEWOO in PDF.

📄 19 pages English EN Download 💬 AI Question
Notice DAEWOO FR-291 - page 15
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about FR-291 DAEWOO

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Fridge in PDF format for free! Find your manual FR-291 - DAEWOO and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FR-291 by DAEWOO.

USER MANUAL FR-291 DAEWOO

: In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center

1. SPECIFICATION

1. MAJOR ACCESSORIES

NAME Q'TY
FREEZER ROOMICING CASE 1
FREEZER SHELF 1
FREEZER POCKET 2
REFRIGERATOR ROOMREF. SHELF 2
COVER VEGETB CASE 1
VEGETABLE CASE 1
EGG CASE 1
EGG POCKET 1
UTILITY POCKET 1
JUMBO POCKET 1
BOTTLE POCKET1

2. QUALITY SPECIFICATION

CLASIFICATIONCONTENTSFR-291
CAPACITY (L)GROSSFREEZER73L
REFRIGERATOR173L
TOTAL246L
STORAGEFREEZER62L
REFRIGERATOR159L
TOTAL221L
EXTERNAL DIMENSIONWIDTH545
DEPTH584
HEIGHT1620
COOLING & CONTROL SYSTEMDEFROST SYSTEMFORCED
DEFROST CONTROLAUTOMATIC START & STOP
COMPRESSORYX58LHP5
REFRIGERANT(g)R-134a, 75 g
REFRIGERATOR DEGREE***
ELECTRIC CHARACTERINPUT VOLTAGE220~240V
COMPRESSOR0.6A
HEATER190W
ELECTRIC CONSUMPTION390 KWh/Year
WEIGHT53 Kg

2. NAME OF FARTS

DAEWOO FR-291 - NAME OF FARTS - 1

text_image CASE ICING F SHELF F TEMP. CONTROL DIAL R TEMP. CONTROL DIAL WINDOW R SHELF COVER VECETB CASE VEGETB CASE R POCKET EGG POCKET ECG CASE UTILITY POCKET JUMBO POCKET BOTTLE POCKET

3. AIR FLOW DIAGRAM

DAEWOO FR-291 - AIR FLOW DIAGRAM - 1

text_image F POCKET 19°C -19°C 19°C 19°C 5~6°C 2~4°C 3~6°C 2~4°C 2~4°C 3~6°C 2~4°C 3~6°C 4~7°C R POCKET REFRIGERATOR ROOM VEGETB CASE

4. REFRIGERANT CYCLE DIAGRAM

DAEWOO FR-291 - REFRIGERANT CYCLE DIAGRAM - 1

flowchart
graph TD
    A["PIPE HOT"] --> B["PIPE *S PLT"]
    B --> C["EVA"]
    C --> D["PIPE SUC."]
    D --> E["COMP"]
    E --> F["PIPE CON(SUC)"]
    F --> G["PIPE CON(DEL)"]
    G --> H["CHARGE PIPE"]
    H --> I["CAPE-TUBE"]
    I --> J["DRYER AS"]
    J --> K["COMPRESSOR"]
    K --> L["PIPE CONN DEL"]
    L --> M["PIPE *S PLT"]
    M --> N["PIPE HOT"]
    N --> O["DRYER AS"]
    O --> P["CAPE-TUBE"]
    P --> Q["PIPE CONN SUC."]
    Q --> R["PIPE SUC"]
    R --> S["EVAPORATOR"]

5. MACHINE ROOM VIEW AND PART LIST

DAEWOO FR-291 - MACHINE ROOM VIEW AND PART LIST - 1

text_image Technical diagram of a vehicle interior with numbered components for identification
NOPART NAMEPART CODEQ'TYMATERIALSPEC.REMARKS
1BASE COMP SAS30103421001O1, T1.0
2ABSORGLR COMP30101034004NRH=40
3COMPRESSOR39561467401JX46LCP4----
4SPECIAL WASHER4019H090302SK-5 T0.8
5SWITCH P-RELAY AS30181289001
6CLAMP BAND RELAY38161001101SK-5 T0.7T0.7 7N-3-A
7COVER RELAY38114005031
8PIPE CONN DEL30144179101DCUT1-O 4.76 × 10.7 × 1.200
9PIPE HOT30144629001TSW 4 × 10.5 × 16434
10PIPE *S PLT30144627001TSW 4.76 × 10.7 × 15914
11PIPE SUC AS30144630001
12DRYER AS30168082001XH-910g
13PIPE CONN SUC30144179101DCUT1-O 6.0 × 10.5 × 1373
14CORD POWER AS30113470001CP-2PIN
15SCREW TAPPING71124012112MFZNTITRS 4x12
16SCREW MACHINE70024010651BSNITRS 4x10
17WASHER TOOTHED74022040111MFZNTE-B-4
18CASE VAPORI30111874001PP
19PIPE SERVICE4019L020201DCUT1-O
20HOSE DRN A30132251001PP
21CAP DRN HOSE B30109280001NBR
22COVER HOUSING30014004001PP

6. WIRE DIAGRAM & SOLID WIRE DIAGRAM

1) WIRE DIAGRAM

DAEWOO FR-291 - 1) WIRE DIAGRAM - 1

flowchart
graph TD
    A["BLU"] --> B["FUSE TEMP."]
    B --> C["BLU"]
    C --> D["SKY BLU"]
    D --> E["SKY BLU"]
    E --> F["SLC"]
    F --> G["R/C"]
    G --> H["P-RELAY"]
    H --> I["PTC 2 OL"]
    I --> J["3"]
    J --> K["BLU"]
    K --> L["BRN BI-METAL"]
    L --> M["BRN"]
    M --> N["COMPRESSOR"]
    N --> O["RED"]
    O --> P["WHT BLU"]
    P --> Q["Timer DEFROST RED"]
    Q --> R["WHT BLU"]
    R --> S["BRN"]
    S --> T["SWITCH DR"]
    T --> U["HTR C/BOX"]
    U --> V["LAMP"]
    V --> W["YEL"]
    W --> X["BLU"]
    X --> Y["GRN/YEL"]
    Y --> Z["PLUG POWER"]
    Z --> AA["BRN"]
    AA --> AB["BRN"]
    AB --> AC["SWITCH DR"]
    AC --> AD["HTR-THERMO"]
    AD --> AE["THERMOSTAT"]
    AE --> AF["BRN SKY BLU"]
    AF --> AG["BRN SKY BLU"]

2) SOLID WIRE DIAGRAM
DAEWOO FR-291 - 1) WIRE DIAGRAM - 2

flowchart
graph TD
    A["Red"] --> B["F/W"]
    B --> C["YEL"]
    C --> D["SKY BLU"]
    D --> E["BI-METAL BRN"]
    E --> F["BRN"]
    F --> G["WHT"]
    G --> H["HTR DEFROST"]
    H --> I["BLU"]
    I --> J["BLU FUSE TEMP. BLU"]
    J --> K["SWITCH DR"]
    K --> L["YEL"]
    L --> M["BLU"]
    M --> N["HTR C/BOX BRN"]
    N --> O["THERMOSTAT YEL"]
    O --> P["SKY BLU"]
    P --> Q["WHT BLU"]
    Q --> R["LAMP BLU"]
    R --> S["YEL"]
    S --> T["WHT"]
    T --> U["TIMER DEFROST BRN"]
    U --> V["WHT BLU"]
    V --> W["P-RELAY"]
    W --> X["RED"]
    X --> Y["QL"]
    Y --> Z["PTC"]
    Z --> AA["YEL"]
    AA --> AB["SKY BLU"]
    AB --> AC["PLUG POWER"]
    AC --> AD["BRN"]
    AD --> AE["GRN/YEL"]

7. MAIN COMPONENTS

  1. COMPRESSOR
FR - 291
MODELYX58LHP5
STARTING TYPE RSCR
VOLTAGE 230V / 50Hz
MAIN COIL RESISTANCE19.4Ω
SUB COIL RESISTANCE25.6Ω
  1. RELAY
FR - 291
MODEL4TM129SHBYY-52
PTCRESISTANCE33Ω
MAX. VOLTAGE355V
MAX. CURRENT6A
OL CURRENT 3.5A
  1. RUNNING CAPACITOR
FR - 291
VOLTAGEAC
RATED CAPACITY4 μF

400V

  1. LAMP
FR - 291
VOLTAGEAC 240V / 15W

5. POWER CORD

FR-291
TYPE3x0.75 mm^2
LENGTH1.80m

6. TEMPERATURE FUSE

FR - 291
VOLTAGE250V
CURRENT10A
WORKING TEMP.77 °C

7. Bi-METAL

FR - 291
MODEL PST - 3
OFF TEMP. 12 ± 3

7. DEFROST TIMER

FR - 291
MOEDLCF-3001-21
CYCLE TIME 12 HR± 10.8 MIN

8. DEFROST HEATER

FR - 291
RATING AC 230V / 190W
RESISTANCE269 Ω
  1. FAN MOTOR
FR - 291
MODELDAI-6122-DESFD
TYPESHADED
RATING230V/50HZ
INPUT5.0W
POLE2
RPM 2000 ± 150 rpm

POLE

POLE

  1. R-THERMOSTAT
FR - 291
MODELGNF-175D-01F(1)
RATINGAC 25
ON/OFF TEMP.2.5 ± 2.5 °C

250V/60Hz

  1. DOOR SWITCH
FR - 291
TYPE 1 BUTTON 2 PIN
RATINGAC 2
MODELWDS

250V/0.5A

001C-01

  1. CONTL BOX HEATER
FR - 291
RATING AC 220V / 4W
RESISTANCE12100 Ω

DAEWOO FR-291 - DEFROST HEATER - 1

F ROOM
DAEWOO FR-291 - DEFROST HEATER - 2

R ROOM
DAEWOO FR-291 - DEFROST HEATER - 3

text_image 56 67 OPTION

DAEWOO FR-291 - DEFROST HEATER - 4

text_image Exploded view diagram of a refrigerator with numbered parts for identification

DAEWOO FR-291 - DEFROST HEATER - 5

DAEWOO FR-291 - DEFROST HEATER - 6

text_image 58 30 40

DAEWOO FR-291 - DEFROST HEATER - 7

text_image MECH ROOM 55 56 57 58 59 60 15 61 52 51 54 62 63 64
NOPART CODEPART NAMEQ'TYREAMRK
1 3010815700 CABINETURT AS 1
2 3011755200 DOOR S/W AS 1 WDS001C-01
3 3012924600 HINGE *T AS 1
4 3016000301 SPECIAL BOLT 3 M5 x L14
5 3001400000 COVER *T HI 1 PP
6 3012924500 HINGE *M AS 1
7 3016004000 SPECIAL BOLT 2 M6 x L10
8 3012924700 HINGE *U AS 1
9 7650602511 BOLT HEX 2 M6 x L25
103012105300 FOOT ADJ AS 2 PP+INSERT
113001400200 COVER FAN A 1 HIPS
123013412000 KNOB F CONTL 1 HIPS-c
134017Z42312 FAN 1 ABS ID3.17 ∅100
143001400600 COVER SCREW 2 HIPS
157112401211 SCREW TAPPING 4 T1TRS 4x12 MFZN
163018921800 LOUVER F 1 PP-c
173015917200 MOTOR F AS 1 230V/50Hz
183012024600 FIXTURE MOTOR A 1 PP
197122401211 SCREW TAPPING 2 T2TRS 4x12
203017062000 EVA SAS 1
213014120100 PAD EVA *L 1 F-PS
223014120200 PAD EVA *R 1 F-PS
233017202500 FUSE TEMP AS 1 105T,AC250V/10A
243018128700 SWITCH BIMETAL 1 PST-3SW-
254016N03280 CLAMP CABLE 3 NYLON-66, W3.6xL146
263012820200 HEATER SHEATH SAS 1 AC 220V, 175W
273010549100 BOX CONTL 1 HIPS
283013358100 INSU R DUCT *T 1 F-PS
293013358200 INSU R DUCT *U 1 F-PS
303018128310 SWITCH TIMER 1 220V/50Hz, 12HR
313018304900 THERMOSTAT 1
323013412100 KNOB R CONTL 1 HIPS
333017906700 SOCKET R LAMP AS 1 220V/15W
347112401011 SCREW TAPPING 2 T1TRS 4x10 MFZN
353015511000WINDOW R1GPPS
363011187300CASE ICING1PP
373017843700SHELF F1GPPS
383017843600SHELF R2GPPS
39 3001400700 COVER VEGETB CASE 1 GPPS
403011187600CASE VEGETB1 GPPS
413019027900POCKET F2 GPPS
42 3012319500 GASKET F DR AS 1 PVC-S+MAGNET
433011766900DOOR F URT AS1
443011187200CASE EGG1 PP
453019027800POCKET EGG1 GPPS
463019028200POCKET UTILITY1 GPPS
473019028000POCKET JUMBO1 GPPS
483019028100POCKET R1 GPPS
49 3012319600 GASKET R DR AS 1 PVC-S+MAGNET
503011767000DOOR R URT AS1
513956158K50COMPRESSOR1YX58LHP5
524019H09030SPECIAL WASHER2SK-5, T0.8
53 3010103400 ABSORBER WASHER 4 NR H=40
54 3010342100 BASE COMP SAS 1 GI, T1.0
553001400400COVER HOUSING1 HIPS(n)
563016404700CAPACITOR RUNNING1 400VAC, 4 μF, CLASS C
573816100110CLAMP BAND RELAY1
58 3018130300 SWITCH P RELAY AS 1 4TM 129SHBYY-52
593811400503COVER RELAY1 PP
603011348011CORD POWER AS1
61 3013225100 HOSE DRN A 1 PP
623011187400CASE VAPORI1 PP
63 3016808200 DRYER AS 1 XH-9, 10g
643016003300SPECIAL BOLT2 M6.5x20
657650601511BOLT HEX2 M6x15
66 3017843500 SHELF CHILLED CASE 1 GPPS
673011112011CASE CHILLED1GPPS

9. Methods of exchanging main parts.

1. F LOUVER PART

DAEWOO FR-291 - F LOUVER PART - 1- Remove the screw cap, and unscrew the fixing screw(2EA).
DAEWOO FR-291 - F LOUVER PART - 2- Pull the louver forward, grasping at the fan cover and upper corner of louver.
DAEWOO FR-291 - F LOUVER PART - 3- Disassemble fan motor harness and remove Louver As..
DAEWOO FR-291 - F LOUVER PART - 4- Unscrew the fixing screw at the back of louver(hidden under Al tape).- To remove the fan cover, pull the bottom of fan cover.

2. EVAPORATOR PART

DAEWOO FR-291 - EVAPORATOR PART - 1- Pull the suction pipe and capi. Tube forward, with care not to bend the pipes sharply.
DAEWOO FR-291 - EVAPORATOR PART - 2- Hold up evaporator and pull it forward.
DAEWOO FR-291 - EVAPORATOR PART - 3- Remove the evaporator pad.
DAEWOO FR-291 - EVAPORATOR PART - 4- To remove defrost heater, cut the clamp cable first, disassemble the harness then pull down the heater.- The assembling procedure of new heater is the reverse of disassemble steps.

DAEWOO FR-291 - EVAPORATOR PART - 5

natural_image Close-up of a hand inserting wires into a refrigerated appliance (no visible text or symbols)

- To exchange the Bi-Metal, first cut the clamp cable then disassemble the harness.

DAEWOO FR-291 - EVAPORATOR PART - 6

natural_image Close-up of hands installing a coiled electrical heating element in a refrigerated room (no visible text or symbols)

- Extract the Temp. Fuse in the evaporator then disassemble the harness.

- The new Temp. Fuse should be located in the same position in the evaporator.

3. CONTROL BOX PART

DAEWOO FR-291 - CONTROL BOX PART - 1

natural_image Hand inserting a plastic clip into a white refrigerator (no text or symbols visible)

- To remove the temperature control dail, Pull it down.

DAEWOO FR-291 - CONTROL BOX PART - 2- Unscrew the fixing screw(1EA).
DAEWOO FR-291 - CONTROL BOX PART - 3- Pull down the control box, then disassemble the harness.
DAEWOO FR-291 - CONTROL BOX PART - 4- Remove the lamp cover with screwdriver etc. pushing the front hooker part of the cover then lift up the cover.
DAEWOO FR-291 - CONTROL BOX PART - 5- Unscrew the fixing screw of the lamp socket.

DAEWOO FR-291 - CONTROL BOX PART - 6

natural_image Close-up of hands assembling or adjusting a small mechanical component on a white electronic device (no visible text or symbols)
  • Pull the lamp forward, then disassemble the connector.
  • The assembling procedure of new lamp is the reverse of disassemble steps.

4. DOOR SWITCH PART

DAEWOO FR-291 - DOOR SWITCH PART - 1

text_image Person installing a label on a wall-mounted fixture, showing a green card with handwritten text and a tool.

- In removing the door switch, push the door switch left, insert a pointed rods as screw-driver in the right gap, and push the rod left and pull the door switch forward.

- Be careful not to harm the surface of cabinet . (Use name plate etc. under the pointed rod)

DAEWOO FR-291 - DOOR SWITCH PART - 2

natural_image Close-up of hands installing or connecting wires on a wall-mounted appliance (no visible text or symbols)

- Pull the door switch forward and remove the harness.

DAEWOO FR-291 - DOOR SWITCH PART - 3

natural_image Hand inserting a small white component into a door handle (no text or symbols visible)

- In inserting new door switch, insert the left part of the switch in the hole then push the right part of refrigerator.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : DAEWOO

Model : FR-291

Category : Fridge