PAR 20 Warm-On-Dim - Lighting Showtec - Free user manual and instructions
Find the device manual for free PAR 20 Warm-On-Dim Showtec in PDF.
User questions about PAR 20 Warm-On-Dim Showtec
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Lighting in PDF format for free! Find your manual PAR 20 Warm-On-Dim - Showtec and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PAR 20 Warm-On-Dim by Showtec.
USER MANUAL PAR 20 Warm-On-Dim Showtec
natural_image
Technical line drawing of a mechanical device with internal components and mounting brackets (no text or symbols)ENGLISH
PAR 20 Warm-On-Dim V2
Ordercode: 43312
Table of contents
Warning 2
Safety Instructions 2
Operating Determinations 4
Rigging 4
Connection with the mains....5
Return Procedure....5
Claims....5
Description of the device....6
Optional accessories....6
Overview 6
Installation....7
Set Up and Operation....7
Filter frame retaining clip....7
Maintenance....7
Troubleshooting 8
No Light 8
Product Specifications....9
Dimensions....10
Warning

For your own safety, please read this user manual carefully before your initial start-up!

Unpacking Instructions
Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure that all parts are present, and have been received in good condition. Notify the dealer immediately and retain packing material for inspection if any parts appear to be damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that the fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Your shipment includes:
Showtec PAR 20 Warm-On-Dim with 0,5m Schuko power cable
1x Filter frame
User manual

natural_image
Technical line drawing of a mechanical device with no visible text or symbols
CAUTION!
Keep this device away from rain and moisture!
Unplug mains lead before opening the housing!

Safety Instructions
Every person involved with the installation, operation and maintenance of this device has to:
- be qualified
• follow the instructions of this manual

CAUTION! Be careful with your operations.
With a dangerous voltage you can suffer a dangerous electric shock when touching the wires!

Before your initial start-up, please make sure that there is no damage caused by transportation. Should there be any, consult your dealer and do not use the device.
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
Please consider that damages caused by manual modifications to the device are not subject to warranty.
This device contains no user-serviceable parts. Refer servicing to qualified technicians only.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
- Never let the power cord come into contact with other cables! Handle the power cord and all connections with the mains with particular caution!
- Never remove warning or informative labels from the unit.
- Never use anything to cover the ground contact.
- Never lift the fixture holding it by the projector-head, as the mechanics may be damaged. Always hold the fixture by the transport handles.
- Never place any material over the lens.
- Never look directly into the light source.
- Never leave any cables lying around.
- Do not insert objects into air vents.
- Do not switch the device on and off in short intervals, as this would reduce the device's lifespan.
- Do not touch the device's housing bare-handed during its operation. Allow the fixture to cool for at least 5 minutes before handling.
- Do not shake the device. Avoid brute force when installing or operating the device.
- Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.
- Only operate the device after having familiarized with its functions.
- Avoid flames and do not put close to flammable liquids or gases.
• Always keep case closed while operating.
• Always allow free air space of at least 50 cm around the unit for ventilation. - Always disconnect power from the mains, when device is not used or before cleaning! Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
• Make sure that the device is not exposed to extreme heat, moisture or dust.
• Make sure that the available voltage is not higher than stated on the rear panel. - Make sure that the power cord is never crimped or damaged. Check the device and the power cord from time to time.
- If the lens is obviously damaged, it has to be replaced to prevent its functions from being impaired, due to cracks or deep scratches.
- If device was dropped or struck, disconnect mains power supply immediately. Have a qualified engineer inspect for safety before operating.
- If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
- If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Showtec dealer for service.
- For adult use only. Device must be installed out of reach of children. Never leave the unit running unattended.
- Never attempt to bypass the thermostatic switch or fuses.
- For replacement, use fuses of same type and rating only.
- The user is responsible for correct positioning and operating of the PAR 20. The manufacturer will not accept liability for damages caused by the misuse or incorrect installation of this device.
- This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.
• Repairs, servicing and electrical connection must be carried out by a qualified technician. - WARRANTY: Till one year after date of purchase.

CAUTION! Eyedamages!!! Avoid looking directly into the lightsource!!! (meant especially for epileptics)!!!

Operating Determinations
- This device is not designed for permanent operation. Regular operation breaks will ensure that the device will serve you for a long time without defects.
- The minimum distance between light-output and the illuminated surface must be bigger than 0.5 meter.
- The maximum ambient temperature ta = 40^ must never be exceeded.
• The relative humidity must not exceed 50 % with an ambient temperature of 40°C. - If this device is operated in any other way than the one described in this manual, the product may suffer damages and the warranty becomes void.
• Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc.
You endanger your own safety and the safety of others!
Rigging
Please follow the European and national guidelines concerning rigging, trussing and all other safety issues.
Do not attempt the installation yourself!
Always let the installation be carried out by an authorized dealer !
Procedure:
• If the PAR 20 is lowered from the ceiling or high joists, professional trussing systems can be used.
• Use a clamp to mount the PAR 20, with the mounting-bracket, to the trussing system.
• The PAR 20 must never be fixed swinging freely in the room.
- The installation must always be secured with a safety attachment, e.g. an appropriate safety net or safety-cable.
- When rigging, derigging or servicing the PAR 20, always make sure, that the area below the installation place is blocked and staying in the area is forbidden.

text_image
Safety cable ClampThe PAR 20 Warm-On-Dim can be placed on a flat stage floor or mounted to any kind of truss by a clamp.
Improper installation can cause serious injuries and/or damage of property!
Connection with the mains
Connect the device to the mains with the power plug.
Always check if the right color cable is connected to the right place.
| International | EU Cable | UK Cable | US Cable | Pin |
| L | BROWN | RED | YELLOW/COPPER | PHASE |
| N | BLUE | BLACK | SILVER | NEUTRAL |
| YELLOW/GREEN | GREEN | GREEN | PROTECTIVE GROUND |
Make sure that the device is always connected properly to the earth!
Improper installation can cause serious damage to people and property!


Return Procedure

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. Call Highlite 0031-455667723 or mail aftersales@highlite.com and request an RMA prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause of the return. Be sure to properly pack fixture as any shipping damage resulting from inadequate packaging is the customer's responsibility. Highlite reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Note: If you are given an RMA number, please include the following information on a piece of paper inside the box:
01) Your name.
02) Your address.
03) Your phone number.
04) A brief description of the symptoms.
Claims
The client has the obligation to check the delivered goods immediately upon delivery for any shortcomings and/or visible defects, or perform this check after our announcement that the goods are at their disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise.
It is the customer's responsibility to notify and submit claims with the shipper in the event that the fixture is damaged due to shipping. Transportation damage has to be reported to us within one day after receipt of the delivery.
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless agreed otherwise in writing.
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the invoice. After this period, complaints will not be handled anymore.
Complaints will only be considered if the client has so far complied with all parts of the agreement, regardless of the agreement of which the obligation is resulting.
Description of the device
Features
The Showtec PAR 20 Warm-On-Dim is a small LED parcan with high output and great effects.
• Input voltage: 230 VAC, 50/60Hz
• Power consumption: 17W (full output)
• Power cable 0,5 m with Schuko connector
• Filter frame: Included
• Light source: 1x 15W Warm-On-Dim LED
• Output: 800 Lumen
• Dimmer: 0-100% (by external dimmer)
- Beam Angle: 45^
• Housing: Black aluminum
• Cooling: Convection
- IP rating: IP20
- Dimensions: 175 x 117 x 140 mm incl. bracket (LxWxH)
- Weight: 0,4 kg
Optional accessories
30153 - Barndoor for Parcan 20
Overview

text_image
Technical diagram of a mechanical device with numbered components labeled 1, 2, 3, and 4.Fig. 01
01) Mounting bracket with inclination screws
02) Filter frame
03) 1x 15W Warm-On-Dim LED
04) Power cable 0,5m with Schuko connector
Installation
Remove all packing materials from the PAR 20 Warm-On-Dim. Check that all foam and plastic padding is removed. Connect all cables.
Do not supply power before the whole system is set up and connected properly.
Always disconnect from electric mains power supply before cleaning or servicing.
Damages caused by non-observance are not subject to warranty.
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
Before plugging the unit in, always make sure that the power supply matches the product specification voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.
Always disconnect from electric mains power supply before cleaning or servicing.
Damages caused by non-observance are not subject to warranty.
Filter frame retaining clip
01) Press and hold down the filter frame retaining clip.
02) Insert the filter frame into the bracket.
03) Release the filter frame retaining clip in order to secure the filter frame in position.

natural_image
Technical diagram of a mechanical clamp or bracket with red arrows indicating direction (no text or symbols)
natural_image
Simple geometric diagram showing a circle inscribed within an octagon (no text or symbols)Fig. 02
Maintenance
The operator has to make sure that safety-relating and machine-technical installations are to be inspected by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be inspected by a skilled person once a year.
The following points have to be considered during the inspection:
01) All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded.
02) There may not be any deformations on housings, fixations and installation spots.
03) Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
04) The electric power supply cables must not show any damages or material fatigue.
The PAR 20 Warm-On-Dim requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the fixture's light-output will be significantly reduced. Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and a soft cloth. Do not use alcohol or solvents.
The front lens will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-output very quickly.
Troubleshooting
No Light
This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, follow the steps below in sequence until a solution is found. Once the unit operates properly, do not carry out the following steps.
If the light effect does not operate properly, refer servicing to a technician.
Suspect two potential problem areas: the power supply and the LED.
01) Power supply. Check that the unit is plugged into an appropriate power supply.
02) The LED. Return the PAR 20 to your Showtec dealer.
03) If all of the above appears to be O.K., plug the unit in again.
04) If you are unable to determine the cause of the problem, do not modify the PAR 20, as this may damage the unit and the warranty will become void.
05) Return the device to your Showtec dealer.
| Problem | Probable cause(s) | Solution |
| One or more fixtures do not function at all | No power to the fixture | Check if power is switched on and cables are plugged in |
| Internal fuse blown | Return the PAR 20 to your Showtec dealer | |
| No light or LED cuts out intermittently | Fixture is too hot | Allow the fixture to cool downClean the fanMake sure air vents in control panel and the front lens are not blockedTurn up the air conditioning |
| LED damaged | Disconnect the fixture and return it to your dealer | |
| The power supply settings do not match local AC voltage and frequency | Disconnect fixture. Check settings and correct if necessary |
Product Specifications
| Model: | Showtec PAR 20 Warm-On-Dim |
| Input Voltage: | 230V AC, 50/60Hz |
| Power consumption: | 17W (full output) |
| IP rating: | IP-20 |
| Dimensions: | 175 x 117 x 140 mm incl. bracket (LxWxH) |
| Weight: | 0,4 kg |
| Electro-mechanical effects: | |
| Light source: | 1x 15W Warm-On-Dim LED |
| Output: | 800 Lumen |
| Beam Angle: | 45° |
| Dimmer: | 0-100% (by external dimmer) |
| Housing: | Black aluminum |
| Connections: | Power cable 0,5m with Schuko connector |
| Cooling: | Convection |
| Max. ambient temperature t_a : | 40°C |
| Max. housing temperature t_B : | 80°C |
| Minimum distance: | |
| Minimum distance from flammable surfaces: | 0,5 m |
| Minimum distance to lighted object: | 1 m |
Design and product specifications are subject to change without prior notice.
CE
Website: www.Showtec.info
Email: service@highlite.com
Dimensions

text_image
117 mm 90 mm 140 mm 94 mm 175 mm 83 mm