Linear PRO Access

CAM-30DN-IP - Security Camera Linear PRO Access - Free user manual and instructions

Find the device manual for free CAM-30DN-IP Linear PRO Access in PDF.

📄 4 pages English EN Download 💬 AI Question
Notice Linear PRO Access CAM-30DN-IP - page 1
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about CAM-30DN-IP Linear PRO Access

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Security Camera in PDF format for free! Find your manual CAM-30DN-IP - Linear PRO Access and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CAM-30DN-IP by Linear PRO Access.

USER MANUAL CAM-30DN-IP Linear PRO Access

aigis mechtronics now part of

Linear® Building On Innovation.

Linear PRO Access CAM-30DN-IP - Linear® Building On Innovation. - 1

natural_image Exterior view of a white electronic device with two ports and a label (no visible text or symbols)

IP Box Camera and Encoders

Linear PRO Access CAM-30DN-IP - Linear® Building On Innovation. - 2

natural_image White camera lens with black lens and control panel (no visible text or symbols)

Linear PRO Access CAM-30DN-IP - Linear® Building On Innovation. - 3

natural_image White surveillance camera mounted on a metallic stand, no visible text or symbols

Linear PRO Access CAM-30DN-IP - Linear® Building On Innovation. - 4

text_image RESOTA CY-10-10 AUTO LINE POWER 3D CARD RESET MACHINE IN AUDIO UNIT EXT HD 1.2.3.4.5.6

CAM-x-IP Series ENC Series
Linear PRO Access CAM-30DN-IP - Linear® Building On Innovation. - 5

flowchart
graph TD
    A["Camera Connectors"] --> B["Dry Contact Relay (Separate Device)"]
    B --> C["External Relay (i.e. Motion Sensor)"]
    C --> D["Magnetic Door Lock"]
    D --> E["Power Supply"]
    E --> F["-V"]
    E --> G["+V"]
    F --> H["+V"]
    G --> I["-V"]
    H --> J["NO NC c"]
    I --> K["-V"]
    J --> L["1 2 3 4 5 6"]
    K --> M["NC Com"]

IMPORTANT SAFEGUARDS

I. Read Instructions - All the safety and operating instructions should be read before the unit is operated.
2. Retain Instructions - The safety and operating instructions should be retained for future reference.
3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to.
4. Follow Instructions - All operating and use instructions should be followed.
5. Cleaning - Unplug the unit from the outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
6. Attachments - Do not use attachments not recommended by the product manufacturer as they may cause hazards.
7. Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit may fall, causing serious injury to a person and serious damage to the unit. Use only with a stand, tripod, bracket, or mount recommended by the manufacturer or sold with the product. Any mounting of the unit should follow the manufacturer's instructions and should use a mounting accessory recommended by the manufacturer.

An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn.

  1. Ventilation - Openings in the enclosure, if any, are provided for ventilation, to ensure reliable operation of the unit, and to protect it from overheating. These openings must not be blocked or covered. This unit
    should not be placed in a built-in installation unless proper ventilation is provided or the manufacturer's instructions have been adhered to.
  2. Power Sources - This unit should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply you plan to use, consult your appliance dealer or local power company. For units intended to operate from battery power or other sources, refer to the operating instructions.
  3. Grounding or Polarization - This unit may be equipped with a polarized alternating-current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarized plug. Alternatively, this unit may be equipped with a 3-wire grounding-type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type plug.
  4. Power Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit from the appliance.
  5. Power Lines - An outdoor system should not be located in the vicinity of overhead power lines or other electric light or power circuits or where it can fall into such power lines or circuits. When installing an outdoor system, extreme care should be taken to keep from touching such power lines or circuits as contact with them might be fatal. U.S.A. models only - refer to the National Electrical Code Article 820 regarding installation of CATV systems.
  6. Overloading - Do not overload outlets and extension cords as this can result in a fire or electric shock.
  7. Object and Liquid Entry - Never push objects of any kind into this unit through openings, as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit.
  8. Servicing - Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
  9. Damage Requiring Service - Unplug the unit from the outlet and refer servicing to qualified service personnel under the following conditions:

a. When the power supply cord or plug is damaged.
b. If liquid has been spilled or objects have fallen into the unit.
c. If the unit has been exposed to rain or water.
d. If the unit does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions, as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the unit to its normal operation.
e. If the unit has been dropped or the cabinet has been damaged.
f. When the unit exhibits a distinct change in performance--this indicates a need for service.

  1. Replacement Parts - When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other
  2. Safety Check - Upon completion of any service or repairs to this unit, ask the service technician to perform safety checks to determine that the unit is in proper operating condition.
  3. Coax Grounding - If an outside cable system is connected to the unit, be sure the cable system is grounded. U.S.A. models only--Section 810 of the National Electrical Code, ANSI/NFPA No.70-1981, provides information with respect to proper grounding of the mount and supporting structure, grounding of the coax to a discharge unit, size of grounding conductors, location of discharge unit, connection to grounding electrodes, and requirements for the grounding electrode.
  4. Lightning - For added protection of this unit during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the cable system. This will prevent damage to the unit due to lightning and power line surges.

FCC NOTICE

This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Relocate the monitor away from the TV/radio receiver.

Plug the monitor into a different wall outlet so that the console is on a different branch circuit.

Re-orient the TV/radio antenna.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions.

NOTE: Changes or modifications to the unit may void FCC compliance.

Linear PRO Access CAM-30DN-IP - FCC NOTICE - 1

CAUT ON

RISK OF ELECTRIC SHOCK. DO NOT OPEN!

Linear PRO Access CAM-30DN-IP - FCC NOTICE - 2

CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPEN COVERS. NO USER SERVICEABLE PARTS ARE INSIDE. REFER SERVICE TO QUALIFIED SERVICE PERSONNEL.

Linear PRO Access CAM-30DN-IP - FCC NOTICE - 3

SAFETY PRECAUTIONS

This label may appear on the bottom of the unit due to space limitations.

The lightning flash with an arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous the product's enclosure that may be of sufficient magnitude to constitute a risk of voltage" within electric shock to persons.

Unpacking

Unpack carefully. This is electromechanical equipment and should be handled with care. If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper. If any items are missing, notify Linear LLC. The shipping carton is the safest container in which the unit may be transported. Save it for possible future use.

Service

If the unit ever needs repair service, the customer should contact Linear LLC for a return product authorization (RPA) and shipping instructions.

Care and Maintenance

Do not remove the cover of the unit at any time. No user-serviceable parts are inside. Perform routine maintenance to keep the unit dust-free. Clean the camera lens as needed. Use a cloth approved by the lens manufacturer. If an approved cloth is not provided, Linear recommends Kimtech Kimwipes™ Delicate Task wipes.

Model Designation

CAM-13DN-IP 1.3MP Day/Night Camera

CAM-30DN-IP 3.0MP Day/Night Camera

ENC-D1POE Encoder, D1 Resolution

Description

These models are box-type IP cameras that are meant for indoor installations. These units can be installed outdoors when installed in a suitable camera enclosure. All Linear IP cameras can be powered over Ethernet (PoE). These models can be powered separately, if desired, with either 12VDC or 24VAC input. All models include a dry contact relay for alarm input (1) and output (1) as well as an RS485 connection.

  • CAM-xxxx-IP models do not include a lens. This camera accepts CS-mount Megapixel lenses. Note that the resolution of the lens must meet or exceed the camera resolution to provide the best possible image. These models support Auto-Iris lenses.
  • The ENC-D1POE model is an encoder which converts an analog video signal to digital for viewing on a network.

Hardware Kit

• CD
- This manual
- Ethernet cable, 5-ft
• Power adapter, 110VAC to 12VDC, 1.0A
- Mount bracket, silver
• 2-pin power connector

Computing Requirements

Hardware:

The minimum computing requirements for viewing the output of the IP camera is a computer capable of running a web browser.

Software:

Linear IP cameras are compatible with Internet Explorer (IE) only. IE7 and IE9 are supported. Update your IE software to the latest version available from Microsoft.

Software Settings:

Set the camera's configuration page to be a "Trusted Site" within Internet Explorer.

  1. Navigate to the camera's web page
  2. From Menu select Tools/Internet Option
  3. Click Security tab, then Trusted Sites
  4. Click Sites, verify URL, then click Add

Linear IP cameras are controlled with the ActiveX plug-in. From the Security tab referenced above:

  1. Click on Trusted Sites
  2. Click on Custom Level
  3. Enable (or set to Prompt) all ActiveX controls and plugins listed below:

a. Allow previously unused ActiveX controls to run without prompt

b. Allow Scriptlets

c. Automatic prompting for ActiveX controls

d. Binary and script behaviors

e. Display video and animation on a webpage that does not use external media player.

f. Download signed ActiveX controls

g. Download unsigned ActiveX controls

h. Initialize and script ActiveX controls not marked as safe for scripting

i. Run ActiveX controls and plug-ins

j. Script ActiveX controls marked safe for scripting

Installation

CAM-13DN-IP & CAM-30DN-IP Box Cameras

ENC-D1POE Encoder

  1. Remove the unit from its packaging.
  2. CAM-x-IP: Remove the rubber pad covering the camera's imager. Install a CS-mount lens by turning clockwise. Plug in the 4-pin DC Iris connector (auto-iris cord) if the lens has this feature.
  3. ENC-D1PIE: Connect the video output of an NTSC-based camera to the encoder via a coaxial cable and BNC plug.

  4. Attach the camera to a mount (camera enclosure, included mount, or other mount). The tapped holes on the top and bottom of the unit accept 1/4-20 screws. The depth of the hole is 0.300-in.

  5. Power the camera via one of three methods.

a. IEEE 802.3af Compliant PoE network switch or injector.
b. 24VAC @ 1.0A supply. The 2-pin connector supplied in the hardware kit accepts 16-28 gauge wire (16-28AWG).
c. 12VDC @ 1.0A supply. An AC adapter is included with the unit.

  1. Connect the camera to a network switch or laptop. Use a standard CAT-5e/6 cable to connect to a switch, or a crossover CAT-5e/6 cable to connect directly to a laptop or PC.

  2. Insert an SD card into the SD card slot if using the onboard recording feature.

  3. The Audio In/Out ports accept standard 3.5mm audio jacks. These units have on-board microphones. If using an external microphone, mute the on-board microphone via the camera's firmware or through the Video Management Software.

a. To use the two-way audio feature, connect an external computer-type speaker to the port labeled "Audio Out".
b. If using an external microphone, connect the device to the port labeled "Mic/Line In".

  1. See Figure 1 if using the External Input/Output (I/O) feature of the camera.

a. Connect Pins 3 & 4 to an external sensor such as a motion sensor. The maximum current available to this circuit is 0.20A.

Linear PRO Access CAM-30DN-IP - ENC-D1POE Encoder - 1

text_image aigis mechtronics Now Part of Linear® Building On Innovation.

1950 Camino Vida Roble, Suite 150

Carlsbad, CA 92008

Tel: 760.438.7000 800.421.1587

www.aigismech.com • www.linearcorp.com

b. Connect Pins 1 & 2 to a dry contact relay (see Figure 2).
c. Connect Pins 5 & 6 to a Pan/Tilt control device such as the Linear Receiver Driver Unit (e.g. RD2PT2-P).

Linear PRO Access CAM-30DN-IP - ENC-D1POE Encoder - 2

text_image BC13V/1A AC24V LINK POWER SD CARD RESET MIC/LINE IN AUDIO OUT EXT NO 1 2 3 4 5 6
Port #Function
1+4.5V
2Digital Output (DO)
3Digital Input(DI)
4 Ground
5 RS485-
6 RS485+

Figure 1 - External I/O Connector

Linear PRO Access CAM-30DN-IP - ENC-D1POE Encoder - 3

flowchart
graph TD
    A["Camera Connectors"] --> B["Dry Contact Relay (Separate Device)"]
    B --> C["External Relay (i.e. Motion Sensor)"]
    C --> D["Magnetic Door Lock"]
    D --> E["Power Supply"]
    E --> F["-V +V"]
    F --> G["+V -V"]
    G --> H["NO NC C"]
    H --> I["1 2 3 4 5 6"]

Figure 2 - Example System Using External Inputs and Outputs

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Linear PRO Access

Model : CAM-30DN-IP

Category : Security Camera