Scarlett

SC-AH986E22 - Humidifier Scarlett - Free user manual and instructions

Find the device manual for free SC-AH986E22 Scarlett in PDF.

📄 21 pages English EN Download 💬 AI Question
Notice Scarlett SC-AH986E22 - page 4
View the manual : English EN Қазақша KK Русский RU Українська UK
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about SC-AH986E22 Scarlett

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Humidifier in PDF format for free! Find your manual SC-AH986E22 - Scarlett and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SC-AH986E22 by Scarlett.

USER MANUAL SC-AH986E22 Scarlett

text_image SCARLETT comfort a24o-fill innovation incented by the light bulb.

GB DESCRIPTION

  1. Mist nozzle
  2. Water tank 4.8 l
  3. Water tank cap
  4. Water inlet
  5. Base
  6. Plug and power cord
  7. Display
  8. Touch panel control
  9. Membrane
  10. Float
  11. Essential oil cup

UA БУДОВА ВИРОБУ

- Please read this instruction manual carefully before use and keep in a safe place for future reference.

- Before the first connecting of the appliance check that voltage indicated on the rating label corresponds to the mains voltage in your home.

- For home use only. Do not use for industrial purposes. Do not use the appliance for any other purposes than described in this instruction manual.

• Do not use outdoors.

• Always unplug the appliance from the power supply before cleaning and when not in use.

• To prevent risk of electric shock and fire, do not immerse the appliance in water or in any other liquids. If it was happened DO NOT TOUCH the appliance, unplug it immediately and check in service center.

- The appliance is not intended for use for physically, sensory or mental disabled person (including children) or for person with lack of life experience or knowledge, if only they are under supervision or have been instructed about the use of the unit by responsible person.

- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and user maintenance shall not be made by children without supervision.

• Children must be under control in order not to be allowed to play with the appliance.

- Do not use other attachments than those supplied.

• In case of power cord is damaged, its replacement should be done by the manufacture or service department or the other high-skill person to avoid any danger.

- Do not attempt to repair, adjust or replace parts in the appliance. Check and repair the malfunctioning appliance in the nearest service center only.

- Keep the cord away from sharp edges and hot surfaces.

- Do not pull, twist, or wrap the power cord around appliance.

- Do not pour the rest water from the gullet when humidifier connected to power supply.

- When wash humidifier, avoid leaking the water into the inner parts of humidifier otherwise the spare part will be humid and cause problem.

- When switch on the appliance, do not touch the energy-exchanger.

- Operate the appliance only with water in the tank. Do not add water over 40^ into the water tank, or use it for cleaning, to avoid possible deformation or discoloring.

• Take the humidifier under bottom and support water tank when handle.

• Do not add water through the mist outlet.

- Do not add water directly to the water channel on the base.

- Do not add metals or chemicals into the water tank and the water channel on the base.

- Avoid water freezing in the humidifier.

- Do not lift the water tank while the humidifier is working.

- Do not pour water from the water channel when humidifier connected to power supply. Otherwise the energy exchanger will immediately break.

- Do not place humidifier close to the ventilating hole and keep away from the furniture and other electrical appliances.

- If the unit was got from the environment with temperature < 0^ , keep it under the room conditions at least 2 hours.

- ATTENTION: unplug the device from the socket before filling or cleaning.

• NOTE. During operation it is acceptable that white bloom occurs on the nearby objects which is caused by high-salinity water being used, in this case we it is recommended to fulter the water before pouring it to water tank of the device.

- The manufacturer reserves the right to introduce minor changes into the product design without prior notice, unless such changes influence significantly the product safety, performance, and functions.

- Manufacturing date is indicated on the unit and/or on packing as well as in accompanying documents in the following format XX.XXXX where first two figures XX is the month of production, and following four figures XXXX is the year of production.

OPERATION

• This appliance is used for indoors air humidifying
- Place the device on an even dry surface.
- ATTENTION: Before pouring water inside, unplug the device
- Remove the tank cover and pour clean water up to the MAX mark so that water does not enter the steam outlet tube.
- ATTENTION: This appliance allows tap water usage. Purified water is still more preferable for usage, especially if tap water is too hard. If tap water is too hard, fill in only distilled or demineralized water.

  • Open the top cover.
  • Fill the water into pouring hole in the base of the device.
  • Close the top cover.
  • Place water tank onto base.
  • Wipe the tank surface using soft cloth.
  • Plug in the device.

Switching on

- Press the button to switch the air humidifier on or off.

Timer Setting

- Press the button ⏻ to select time of humidifier operation (1-8 hours), step 1 hour.

Humidifier Settings

  • The display shows the room temperature, the current steam speed and the timer mode.
  • You can set the level of air humidification (0 to 3). Press the button ⚙️ as many times as needed.

Constant humidity settings (hygrostat function)

- During operation of the device press the 🔊 button to select required relative humidity level.

Relative humidity level can be selected in the range from 40% to 90%. One press of the button equals 5%, During the setting process, selected humidity level will flash on the display. When the room humidity reaches the set level, the device will turn off automatically.

Water Level Indicator

Scarlett SC-AH986E22 - Water Level Indicator - 1

- The water level indicator WATER appears on the display when it is necessary to refill the tank with water.

Aromafunction / Essential oil

  • Put no more than 2-4 drops of essential oil into the essential oil cup before placing water tank onto the base and turning the unit on.
  • Turn on the unit as indicated above.
  • And the scented will be come out with the wind after turn on the machine

CLEAN AND CARE

- Do not forget to unplug the appliance from the power supply before cleaning.

WASH WATER TANK (EVERY TWO OR THREE WEEKS)

• Take off the water tank and turn it up.
- Unscrew the cover.
- Wipe with a soft cloth and rinse water valve.
- Wash water tank with warm water (<40 °C)

CLEAN THE WATER CHANNEL AND THE ENERGY EXCHANGER (ONCE A WEEK).

  • If there is scale in the gullet, clean it with soapy water then rinse with water.
  • If there is any stain on the energy exchange, wipe them off with the soft cloth. Then rinse the appliance with clean water.

IMPORTANT: Use only a soft cloth to clean the energy exchanger. Never touch it with sharp or hard objects.

WASH THE EXTERNAL SURFACE OF HUMIDIFIER

  • First rub the scale and then wash with soft cloth and warm water (<40 °C).
  • Wash the head of sprayer with water directly.

IMPORTANT: Do not use chemicals, organic solvents or aggressive liquids and abrasives.

SCALE REMOVAL

- Hard scale is not allowed to be removed from the unit surfaces mechanically.

  • Fill water tank with water solution of vinegar, one liter of water needs 150ml of vinegar. Instead of vinegar soda can be used, one liter of water needs 2 table spoon of baking soda.
  • The nozzle of the unit should face open window, so that water mist is directed outdoors.
  • Switch air humidifier for 30-60min
  • Water with soda or with vinegar will eat the scale away during unit usage, so that after the procedure the scale will be removed from the unit walls.

STORAGE

  • Switch off and unplug the appliance.
  • Complete all requirements of chapter CLEAN AND CARE.
  • Keep assembled appliance in a dry cool place.

COMMON PROBLEMS AND SOLUTIONS

PROBLEMSCAUSESOLUTION
The mist is smelling1. The appliance is new2. Water is dirty1. Wash the tank and change the waterOpen the water tank and ventilate it for 12 hours
The Indicator light is on, no mist out and no air comingThe water level is excessive high1. Switch off the appliance and unplug it2. Take the water tank off and unscrew the water inlet lid. Pour off some water and close the lid tightly. Wipe the tank dry with a soft cloth. Place water tank back on the base3. Plug the humidifier in. Turn it on
The mist is poorThe energy-changeable appliance has scale or the water is dirtyWash the energy-changeable appliance and change water

Scarlett SC-AH986E22 - STORAGE - 1

The symbol on the unit, packing materials and/or documentations means used electrical and electronic units should not be toss in the garbage with ordinary household garbage. These units should be pass to special receiving point.

For additional information about actual system of the garbage collection address to the local authority.

Valid utilization will help to save valuable resources and avoid negative work on the public health and environment which happens with incorrect using garbage.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Scarlett

Model : SC-AH986E22

Category : Humidifier