Comark

EFG120C - Thermomètre alimentaire Comark - Free user manual and instructions

Find the device manual for free EFG120C Comark in PDF.

📄 4 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Comark EFG120C - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Food Thermometer
Brand Comark
Model EFG120C
Dimensions (Probe Length) Approximately 12 cm
Weight Approximately 50 g
Power Source 1 x CR2032 battery (included)
Display Type Digital LCD
Temperature Range -50°C to 300°C (-58°F to 572°F)
Accuracy ±1°C (±2°F) between -20°C and 100°C
Response Time Less than 10 seconds
Units °C / °F switchable
Auto-off Yes, after 10 minutes of inactivity
Min/Max Memory Yes
Hold Function Yes, data hold
Water Resistance Not waterproof; wipe clean only
Material Stainless steel probe, plastic body
Maintenance Wipe with a damp cloth; do not immerse
Safety Not for oven use; keep out of reach of children
Spare Parts Availability Not available; device is non-repairable
Certification CE, RoHS
Manual Languages English (downloadable PDF)

Frequently Asked Questions - EFG120C Comark

How do I switch between Celsius and Fahrenheit?
Press and hold the °C/°F button for 3 seconds until the display changes.
What type of battery does the EFG120C use and how do I replace it?
It uses one CR2032 battery. Slide open the battery compartment on the back, replace the battery with the positive side up, and close securely.
Can I use this thermometer for grilling or in the oven?
No, the EFG120C is a food thermometer for checking temperature during cooking but is not oven-safe. Do not place the probe in an oven or microwave.
How do I clean the thermometer?
Clean the probe with a damp cloth after each use. Do not immerse the thermometer in water or any liquid.
What is the temperature range of the EFG120C?
The thermometer measures from -50°C to 300°C (-58°F to 572°F).
Why does the display show 'LO' or 'HI'?
'LO' indicates the temperature is below the measuring range, 'HI' indicates it is above. Move the probe to a suitable environment.
How accurate is this thermometer?
The accuracy is ±1°C in the range of -20°C to 100°C (within ±2°F). Outside that range, accuracy may vary.
Does the thermometer have an auto-off feature?
Yes, it will automatically turn off after 10 minutes of inactivity to conserve battery.
How do I use the min/max memory function?
Press the MEM button to cycle between current, minimum, and maximum readings. Press and hold to clear.
Is the probe waterproof?
The probe is not waterproof. It is splash-resistant, but never submerge the entire thermometer in water.

User questions about EFG120C Comark

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermomètre alimentaire in PDF format for free! Find your manual EFG120C - Comark and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. EFG120C by Comark.

USER MANUAL EFG120C Comark

SECTION 1: Identification of the substance/mixture and of the Manufacturer

Chemical Name:

Kerosene (CAS No: 08008-20-6)

Manufacturer Product Name:

Kerosene Spirit Filled Glass Thermometer

Recommended uses of the chemical/product: Kerosene dyed with a red aniline dye is the thermometric fluid in a kerosene spirit filled glass thermometer. The dyed kerosene expands or contracts with change in temperature. The thermometer will have approximately 2 cc of kerosene.

Manufacturer Details:

Emergency Telephone Number:

Miller-Weber of Texas

Chem-Tel, Inc. (Contract Number: MIS0003159)

6952 Lawndale Street 1-800-255-3924

Houston, TX 77023

713-926-2623 Fax: 713-926-7736

SECTION 2: Hazards Identification

The amount of kerosene in a single thermometer is approximately two cc. This section identifies the hazards of the substance, without regard of amount of kerosene present in the finished product.

Hazard Classification of the chemical (GHS-US Hazard Pictograms):

Comark EFG120C - SECTION 2: Hazards Identification - 1
GHS08

Comark EFG120C - SECTION 2: Hazards Identification - 2
GHS07

Comark EFG120C - SECTION 2: Hazards Identification - 3
GHS09

Signal word (GHS-US): Danger

Hazard statements (GHS-US):

H227 – Combustible liquid.

H304 - May be fatal if swallowed and enters airways

H315 – Causes skin irritation

H411 - Toxic to aquatic life with long lasting effects.

Precautionary statements (GHS-US):

P210 – Keep away from heat, sparks, open flames, hot surfaces. – No smoking

P264 – Wash skin, hands thoroughly after handling

P273 - Avoid release to the environment

P280 – Wear eye protection, protective clothing, protective gloves, face mask

P301+P310 - IF SWALLOWED: immediately call a POISON CENTER or doctor/physician

P302+P352 - IF ON SKIN: Wash with plenty of soap and water.

P331 – If swallowed, do NOT induce vomiting

P332+P313 – If skin irritation occurs: Get medical advice/attention

P362 - Take off contaminated clothing and wash before reuse.

P370+P378 – In case of fire: Use carbon dioxide (CO2), powder, alcohol-resistant foam for extinction

P391 – Collect spillage.

P403+P235 - Store in a well-ventilated place. Keep cool.

P405 - Store locked up

P501 – Dispose of contents/container to comply with local, state and federal regulations

NFPA/HMIS Ratings (0-4) (Non-GHS): Health: 2, Flammability: 2, Reactivity: 0, PPG: See Section 8

SECTION 3: Composition/Information on Ingredients

NameProduct Identifier%GHS-US Classification
KerosineCAS No. 08008-20-6100Flam. Liq. 4, H227Skin Irrit. 2, H315Asp. Tox. 1, H304Aquatic Chronic 2, H411

See Section 16 for full text of H-phrases

SECTION 4: First aid measures

The first aid measures described in this section are for exposure to kerosene, regardless of the quantity of the kerosene involved in the exposure. The first aid measures below come from the Safety Data Sheets of our bulk kerosene suppliers.

Description of first aid measures

General: Consult a physician. Show this safety data sheet to the doctor in attendance. Move out of dangerous area.

After inhalation: Move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

After skin contact: Wash off with soap and plenty of water. Consult a physician.

After eye contact: Flush eyes with water as a precaution.

After swallowing (ingestion): Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Most important symptoms and effects, both acute and delayed: The most important known symptoms and effects are described in Section 2 and/or in section 11.

Indication of any immediate medical attention and special treatment needed: No data available.

SECTION 5: Firefighting measures

Extinguishing media

Suitable extinguishing agents: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Unsuitable extinguishing media: None identified, but avoid heavy water stream.

Special hazards arising from the substance or mixture: Nature of decomposition products not known.

Advice to firefighters: Wear self-contained breathing apparatus for firefighting, if necessary.

SECTION 6: Accidental release measures

Personal precautions, protective equipment and emergency procedures

General Measures: If thermometer breaks, wipe up liquid with disposable wiping cloth. Allow to dry under a fume hood and discard or discard into spark and explosion proof waste receptacle. Protective Equipment: See Section 8. Emergency procedures: Keep upwind. Keep away from engines. No smoking. No flames or sparks. Wash contaminated clothing.

Environmental precautions Prevent leakage or spillage into drains and sewers. Discharge into the environment must be avoided.

Methods and material for containment and cleaning up Carefully clean up broken glass. Wipe up liquid kerosene spirit immediately after putting on protective equipment.

Reference to other sections For disposal see section 13.

SECTION 7: Handling and storage

Precautions for safe handling

Handle and store thermometer in such a way to prevent breakage. If thermometer breaks, kerosene will be released. Do not handle until all safety precautions have been read and understood. Avoid contact with skin and eyes. Avoid inhalation of vapor or mist. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in case of breakage. Supply spark and explosion proof waste receptacle, as necessary.

Hygiene measures

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Do not eat, drink or smoke when using this product.

Conditions for safe storage, including any incompatibilities

Store thermometer in such a way to prevent breakage. Store away from direct sunlight, sources of intense heat, or where freezing is possible. Store away from materials incompatible with kerosene (see Section 10 of this SDS). Store in area that will secure kerosene if thermometer is broken in storage. Inspect all incoming containers with thermometers carefully for breakage. If breakage is suspected, use proper protective equipment (see Section 8 of this SDS) and containment. Store and handle in well ventilated areas.

SECTION 8: Exposure controls/personal protection

Control Parameters:

Kerosene (Kerosine) CAS No. 08008-20-6Remarks
USAACGIHACGIH TLV200 mg/m3Central Nervous System impairment; Upper Respiratory Tract irritation; Skin irritation; Application restricted to conditions in which there are negligible aerosol exposures; Confirmed animal carcinogen with unknown relevance to humans; Danger of cutaneous absorption varies.
USANIOSHNIOSH TWA100 mg/m3A refined petroleum solvent (predominantly C9-C16), which typically is 25% normal paraffins, 11% branched paraffins, 30% monocycloparaffins, 12% dicycloparaffins, 1% tricycloparaffins, 16% monomuclear aromatics & 5% dinuclear aromatics.

Appropriate Engineering controls

Emergency eye wash fountains and safety showers should be available in the immediate vicinity of any potential exposure. Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of the workday.

Personal Protective Equipment (if thermometer breaks)

If thermometer breaks, avoid all unnecessary exposure. Gloves. Protective clothing. Safety glasses or goggles. Respiratory protection if concentration in air is above the exposure limits.

Comark EFG120C - Personal Protective Equipment (if thermometer breaks) - 1

Comark EFG120C - Personal Protective Equipment (if thermometer breaks) - 2

Comark EFG120C - Personal Protective Equipment (if thermometer breaks) - 3

Comark EFG120C - Personal Protective Equipment (if thermometer breaks) - 4

Comark EFG120C - Personal Protective Equipment (if thermometer breaks) - 5

Hand Protection: Handle with gloves. Nitrile rubber give good protection. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.

Eye Protection: Safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US). Use a face shield if misting or large quantities of liquid splashing is expected.

Respiratory Protection: Where risk assessment shows air-purifying respirations are appropriate use a full-face respirator with multi-purpose combination (US) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US).

Skin and Body Protection: Complete suit protecting against chemicals. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Control of environmental exposure: Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

SECTION 9: Physical and chemical properties

Appearance (physical state, color)Red dyed liquidExplosion Limit (upper/lower)5% (V)/0.7% (V)
OdorNo data availableVapor pressure0.31 hPa at 20 °C
Odor thresholdNo data availableVapor densityNo data available
pH valueNo data availableRelative density0.800 g/cm3 at 15 °C
Melting/Freezing pointNo data availableSolubilities (at 25 °C)No data available
Boiling point/ Boiling range175-325 °CPartition coefficient (n-octanol/water)No data available
Flash point70 °CAuto/Self-ignition temperatureNo data available
Relative Evaporation rate (butylacetate=1)No data availableDecomposition temperatureNo data available
Flammability (solid, gaseous)No data availableViscosityNo data available
Upper/Lower flammability limits5% (V)/ 0.7% (V)Surface tension32 mN/m at 20 °C

SECTION 10: Stability and reactivity

Reactivity: No data available.

Chemical stability: Stable under normal conditions of use. Stable under recommended storage conditions.

Possibility of hazardous reactions: No data available

Conditions to avoid: Intact thermometer should not be exposed to hydrofluoric acid. Avoid Excessive heat, sources of ignition, direct sunlight and extremely high or low temperatures. If broken, avoid materials incompatible with kerosene.

Incompatible materials: Strong oxidizing agents, strong bases, strong acids, amines.

Hazardous decomposition products: Other decomposition products- no data available. In the event of fire: see Section 5.

SECTION 11: Toxicological information

Acute toxicity: Not classified

Kerosene (Kerosine) CAS No. 08008-20-6

LD50 oral rat2835 mg/kg Remarks: Behavioral: Muscle weakness. Lungs, Thorax, or Respiration: Respiratory stimulation. Endocrine: Hypoglycemia.
dermal rabbitIrritating to skin – 24 h (Draize Test). No other data available.
LD50 inhalation rat (mg/l)No data available.

Skin corrosion/irritation: Irritating to skin.

Serious eye damage/irritation: No data available.

Respiratory or skin sensitization: No data available.

Germ cell mutagenicity: No data available.

Carcinogenicity: No component of this products present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC, NTP or OSHA.

Reproductive toxicity: No data available.

Specific target organ toxicity- (single exposure): Inhalation – Respiratory system.

Specific target organ toxicity- (repeated exposure): No data available.

Aspiration hazard: May be fatal if swallowed and enters airways.

Additional Information: RTECS: OA5500000. The supplier bulk chemical SDS explains to the best of their knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated.

See Section 4 of the SDS for most important symptoms and effects, both acute and delayed for inhalation, skin contact, eye contact, ingestion and chronic symptoms of kerosene exposure.

SECTION 12: Ecological information

Exotoxicity: No data available.

Persistence and degradability: No data available.

Bioaccumulative: No data available.

Mobility in soil (Kerosene CAS No. 08008-20-6):

Surface tension:

32 mN/m (20 °C)

Other adverse effects: An environmental hazard cannot be excluded in the event of unprofessional handling or disposal. Toxic to aquatic life with long lasting effects.

SECTION 13: Disposal considerations

Waste disposal recommendations:

In bulk quantities, this combustible material may be burned in a chemical incinerator equipped with an afterburner and scrubber. Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose this material. Contaminated packaging should be disposed of as unused product.

SECTION 14: Transport information

The shipping of Kerosene spirit filled glass thermometers is not regulated. Thermometers should be packaged in such a way to avoid breakage. They should also be packed so that if breakage occurs, kerosene does not leak from the container. The information below is for bulk kerosene shipments.

Transport document description: UN1223

UN-Number (DOT): UN1223

DOT proper shipping name: Kerosene (Kerosine)

Transport hazard class(es):

Hazard Classes (DOT):

3- Class 3 – Flammable and combustible liquid 49 CFR 173.120

Hazard labels (DOT):

3 – Flammable liquid

Comark EFG120C - SECTION 14: Transport information - 1

Packing group (DOT): III

SECTION 15: Regulatory information

United States (USA)

SARA Section 302: No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.

SARA Section 311/312 (Specific toxic chemical listings): Immediate (acute) health hazard; Fire hazard

SARA Section 313 (Specific toxic chemical listings): This material does not contain any chemical components with known CAS numbers that exceed the threshold (DeMinimis) reporting levels established by SARA Title III, Section 313.

Proposition 65 (California): This product does not contain any chemicals known to the State of California to cause cancer, birth defects, or any other reproductive harm.

Massachusetts, Pennsylvania and New Jersey Right to Know Components: Kerosine CAS No. 08008-20-6 Revision Date: 2007-03-01

SECTION 16: Other information

Full text of H-phrases: see section 3

Asp. Tox. 1Aspiration hazard, Category 1
Flam. Liq. 4Flammable liquids, Category 4
Aquatic Chronic 2Chronic Aquatic Toxicity, Category 2
Skin Irrit. 2Skin corrosion/irritation, Category 2
H227Combustible liquid.
H304May be fatal if swallowed and enters airways
H315Causes skin irritation
H411Toxic to aquatic life with long lasting effects.

Other Information

Miller-Weber of Texas believes that the information contained herein (including data and statements) is accurate as of the date hereof. NO WARRANTY OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, IS MADE AS CONCERNS THE INFORMATION HEREIN PROVIDED. The information provided herein relates only to the specific product designated and may not be valid where such product is used in combination with any other materials or in any process. Further, since the conditions and methods of use of the product and information referred to herein are beyond the control of Miller-Weber of Texas. Miller-Weber of Texas expressly disclaims any and all liability as to any results obtained or arising from any use of the product or such information. No statement made herein shall be construed as a permission or recommendation for the use of any product in a manner that might infringe on existing patents. Technical information included contains information provided by the bulk chemical suppliers to Miller-Weber of Texas.

Prepared: April 1, 2016

Effective Date: April 1, 2016

No previous publication of SDS by Miller-Weber of Texas

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Comark

Model : EFG120C

Category : Thermomètre alimentaire