Product TypeMedical Switching Power Supply (PCB Type)
ModelRPS-65-48
Output Voltage48 VDC
Output Current1.35 A
Output Power65 W
Input Voltage Range85-264 VAC
Input Frequency47-63 Hz
Efficiency (Typ.)89%
ProtectionShort Circuit, Overload, Overvoltage
Safety StandardsMedical (IEC 60601-1, UL 60601-1)
EMC StandardsEN 55011, EN 61000-3-2, EN 61000-4-2,3,4,5,6,8,11
Cooling MethodConvection (no fan required)
Operating Temperature Range-20 to +70 °C (derating above 40°C)
Storage Temperature Range-40 to +85 °C
Dimensions (L x W x H)Approx. 101.6 x 50.8 x 30.5 mm (4 x 2 x 1.2 in)
WeightApprox. 0.2 kg (0.44 lb)
Input Connector2-pin or 3-pin terminal (see datasheet)
Output Connector3-pin Molex or terminal
Warranty3 years (standard)
ManufacturerMean Well Enterprises Co., Ltd.
Country of OriginTaiwan
CertificationsCE, FCC, UL, RoHS, China RoHS

Frequently Asked Questions - RPS-65-48 Mean Well

What is the typical output voltage and current for the RPS-65-48?
The RPS-65-48 provides a nominal output voltage of 48 VDC and a rated output current of 1.35 A, delivering up to 65 W of power.
What input voltage range does the RPS-65-48 accept?
It accepts a universal AC input voltage range of 85 to 264 VAC at 47-63 Hz, making it suitable for global use.
How should I install the RPS-65-48 in my system?
Before installation, disconnect the system from the utility. Mount the PCB unit with at least 5 mm insulation distance from surrounding components. Use a Mylar film if needed. Ensure adequate ventilation with 10-15 cm clearance from heat sources. Refer to the user manual for details.
What wire gauge is recommended for connecting the power supply?
For PCB units, recommended wire sizes are: 18 AWG for up to 6 A, 16 AWG for 6-10 A, 14 AWG for 10-16 A, 12 AWG for 16-25 A, and 10 AWG for 25-32 A. Always secure stranded wires fully into terminals.
Is the RPS-65-48 suitable for medical applications?
Yes, the RPS-65 is part of Mean Well's medical series and complies with medical safety standards such as IEC 60601-1 and UL 60601-1, making it suitable for medical equipment.
How do I protect the power supply from overheating?
Operate the unit within the specified temperature range (-20 to +70 °C). Derate output current above 40 °C. Ensure proper airflow and avoid blocking ventilation holes. For units over 120 W, forced cooling may be required, but the 65 W model typically uses convection cooling.
What should I do if the power supply does not produce any output?
First, check the AC input voltage and connections. Verify that the output terminals are properly connected and not short-circuited. If the unit is overloaded or exceeds the rated output, it may enter protection mode. Disconnect the load and reconnect after a few seconds. If the issue persists, consult a qualified technician.
Can I mount the RPS-65-48 in any orientation?
Mounting orientations other than the standard position may require output current derating due to increased internal temperatures. Refer to the specification sheets for the optimum mounting orientation and derating curves.
Does the RPS-65-48 require an external fuse?
The unit has built-in protection against short circuit, overload, and overvoltage, but for additional safety, an external fuse on the AC input line is recommended. Use a time-lag fuse rated for the input current.
How do I clean and maintain the power supply?
Disconnect the unit from power before cleaning. Use a dry, soft cloth to remove dust from the casing and ventilation holes. Avoid using liquids or solvents. Periodically inspect for loose connections or signs of damage. No internal maintenance is required by the user.

User questions about RPS-65-48 Mean Well

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual RPS-65-48 - Mean Well and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RPS-65-48 by Mean Well.

USER MANUAL RPS-65-48 Mean Well

● Type : Medical Switching Power Supply

(1) Enclosed (Families: MSP)
(2) Modular (Families: MP, NMP)
(3) PCB (Families: MPS, MPD, MPT, MQ, RPS, RPD, RPT, RPTG, NEM, PM)
(4) Adaptor (Families: GSM, MES)

- Installation

(1) Enclosed Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Keep enough insulation distance between mounting screws and internal components of Enclosed units. Please refer to case drawing on specifications to receive the maximum length of mounting screw.
(e) Recommended wires of Enclosed units are shown as below.

AWG1816141210
Rated Current of Equipment (Amp)6A6-10A10-16A16-25A25-32A32-40A
Cross-section of Lead( mm^2 )0.751.001.52.54
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more strips should not exceed 80% of current rating.

8

Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

(f) For other information about the products, please refer to www.meanwell.com for details.

(2) Modular Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Keep enough insulation distance between mounting screws and internal components of Modular units. Please refer to case drawing on specifications to receive the maximum length of mounting screw.
(e) Recommended wires of Modular units are shown as below.

AWG1816141210
Rated Current of Equipment (Amp)6A6-10A10-16A16-25A25-32A32-40A
Cross-section of Lead( mm^2 )0.751.001.52.54
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more strips should not exceed 80% of current rating.

8

Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

(f) For other information about the products, please refer to www.meanwell.com for details.

Installation Manual

(3) PCB Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Recommended wires of PCB units are shown as below.

AWG1816141210
Rated Current of Equipment (Amp)6A6-10A10-16A16-25A25-32A32-40A
Cross-section of Lead( mm^2 )0.751.001.52.54
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more strips should not exceed 80% of current rating.

8

6

Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

(e) At least 5mm insulation distance on the bottom of PCB units should be kept and a Mylar film should be added between the units and the system. In addition, keep enough insulation distance of 15mm around the PCB units.
(f) PCB units greater than 120W may require a forced air/fan for cooling. Please refer to specifications to receive a minimum air intensity and air-flow direction.
(g) For other information about the products, please refer to www.meanwell.com for details.

(4) Adapter Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Before attaching the DC plug of an adaptor to equipment, please unplug the adaptor from the AC power and verify the unit is within the voltage and current rating on the equipment.
(e) Keep the linkage between the adaptor and its power cord tightly as well as connecting the DC plug to equipment properly.
(f) Protect the power cord of adaptors from being trodden on or being squashed.
(g) An approved power cord of an adaptor should greater or equal to SVT, 3G×18AWG or H03VV-F, 3G×0.75mm2.
(h) If the final equipment is not used for long period of time, disconnect the equipment from adaptors to avoid being damaged by voltage peaks or lightning strike.
(i) For other information about the products, please refer to www.meanwell.com for details.

- User Manual

NMP series:

http://www.meanwell.com/webapp/product/search.aspx?prod=NMP1K2&pdf=Tk1QLUUucGRm&a=4

● Warning / Caution !!

(1) Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do not remove the case of the power supply by yourself! Please do not install the units in places with high moisture or near the water.
(2) Please do not install the units in places with high ambient temperature or near fire source. The maximum ambient temperature, please refer to their specifications.
(3) Output current and output wattage must not exceed the rated values on specifications.
(4) To avoid risk of electric shock, for class I products, the ground (FG) must be connected to protective earth.
(5) The Enclosed, Modular and PCB units are designed in accordance with EMC regulations and the related test reports are available by request. Since they are belong to component power supplies and will be installed inside system enclosure, when they are integrated into a system, the EMC characteristics of the end system must be re-verified again.

Manufacturer :

MEAN WELL ENTERPRISES Co., LTD.

No.28, Wuquan 3rd Rd., Wugu Dist.,

New Taipei City 24891, Taiwan

Tel: +886-2-2299-6100

Web: www.meanwell.com

Branch Office :

China

MEAN WELL (GUANGZHOU)

ENTERPRISES Co., LTD.

2F, A Building, Yuean Industry Park,

Huangcun, Dongpu Yown, Tianhe

District, Gungzhou, China

Post Code:510660

Tel: +86-20-2887-1200

Web: www.meanwell.com.cn

U.S.A.

MEAN WELL USA, INC.

44030 Fremont Blvd., Fremont,

CA 94538, U.S.A.

Tel: +1-510-683-8886

Web: www.meanwellusa.com

Europe

MEAN WELL EUROPE B.V.

Langs de Werf 8, 1185XT

Amstelveen, The Netherlands

Tel: +31-20-758-6000

Web: www.meanwell.eu

Declaration of China RoHS Conformity

In order to reduce the impacts on the environment and take the more responsibility for protecting the earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products.

Environment Friendly Use Period Label

Mean Well RPS-65-48 - Environment Friendly Use Period Label - 1Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly Use Period of Electronic Information Products Appendix B, adopting table look-up to verify the Environment Friendly Use Period

Names and Contents of Hazardous Substances Lists

Part NameHazardous Substances
Lead(Pb)Mercury(Hg)Cadmium(Cd)Hexavalent chromium( Cr^6+ )Polybrominated biphenyls(PBB)Polybrominated diphenyl ethers(PBDE)
PCB and its componentsXOXOOO
Metal structure partsXOOOOO
Plastic structure partsOOOOOO
AccessoriesOOOOOO
CablesXOOOOO
O: The concentration of the hazardous substances within the homogeneous material of that product is less than the concentration limits set by GB/T 26572-2011.X: The concentration of the hazardous substances within the homogeneous material of that product is over the concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.