Product Type Medical Switching Power Supply
Series RPT-160C
Category PCB Mount Type (Family: RPT)
Output Power 160 W (nominal)
Input Voltage AC mains (typical 85-264 VAC, refer to specification)
Medical Safety Designed for medical applications with isolation
Cooling Method Convection (forced air recommended for >120 W models)
Installation Type PCB mount with component-side clearance
Wire Gauge Recommendation AWG 18-10 depending on load current (see manual)
Mounting Orientation Standard orientation recommended; de-rating required for others
Protection Features Short circuit, overload, over voltage (typical)
EMC Compliance Designed per EMC regulations; final system must re-verify
Safety Clearance Min 5 mm bottom insulation, 15 mm around PCB
Operating Temperature Refer to specification sheet for maximum ambient
Humidity High moisture areas not allowed
Warranty Standard Mean Well warranty (contact factory)
Manufacturer Mean Well Enterprises Co., Ltd. (Taiwan)

Frequently Asked Questions - RPT-160C Mean Well

How should I install the RPT-160C power supply?
Before installation, disconnect all power. Mount the PCB unit with at least 5mm insulation distance on the bottom and 15mm clearance around it. Use a Mylar film between the unit and system if needed. Follow the recommended wire gauge for the load.
What wire gauge should I use for the RPT-160C?
Refer to the table in the manual: for currents up to 6A use AWG 18, 6-10A use AWG 16, 10-16A use AWG 14, 16-25A use AWG 12, 25-32A use AWG 10. For 5 or more strips, do not exceed 80% of the rated current.
What safety precautions must be taken?
Risk of electric shock. Only qualified technicians should handle failures. Do not remove the case. Keep the unit away from moisture and high temperatures. For Class I products, connect the ground (FG) to protective earth.
What is the maximum ambient temperature for operation?
The maximum ambient temperature is specified in the product's specification sheet. Operating at high temperatures may require output current de-rating. Ensure adequate ventilation.
Is the RPT-160C suitable for medical equipment?
Yes, it is a medical switching power supply designed for medical applications. However, final system EMC verification is required when integrated into equipment.
How can I ensure proper cooling?
Keep fans and ventilation holes unobstructed. Maintain 10-15 cm clearance from adjacent heat sources. For units over 120W, forced air cooling may be required. Refer to the specification for minimum air intensity.
What should I do if the power supply fails?
All failures should be examined by a qualified technician. Do not attempt to repair yourself. Contact Mean Well support or an authorized service center.
Can I mount the RPT-160C in any orientation?
Mounting orientations other than the standard orientation may increase internal component temperature and require output current de-rating. Consult the specification sheet for optimum mounting position.
What is the input voltage range?
The RPT-160C is designed for AC mains input. Typical ranges are 85-264 VAC, but please check the specific model's specification sheet for exact values.
Does the RPT-160C come with a warranty?
Mean Well products are covered by a standard warranty. For detailed warranty terms, contact Mean Well directly or refer to the product documentation.

User questions about RPT-160C Mean Well

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual RPT-160C - Mean Well and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RPT-160C by Mean Well.

USER MANUAL RPT-160C Mean Well

● Type : Medical Switching Power Supply

(1) Enclosed (Families: MSP)
(2) Modular (Families: MP, NMP)
(3) PCB (Families: MPS, MPD, MPT, MQ, RPS, RPD, RPT, RPTG, NEM, PM)
(4) Adaptor (Families: GSM, MES)

- Installation

(1) Enclosed Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Keep enough insulation distance between mounting screws and internal components of Enclosed units. Please refer to case drawing on specifications to receive the maximum length of mounting screw.
(e) Recommended wires of Enclosed units are shown as below.

AWG1816141210
Rated Current of Equipment (Amp)6A6-10A10-16A16-25A25-32A32-40A
Cross-section of Lead( mm^2 )0.751.001.52.54
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more strips should not exceed 80% of current rating.

8

Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

(f) For other information about the products, please refer to www.meanwell.com for details.

(2) Modular Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Keep enough insulation distance between mounting screws and internal components of Modular units. Please refer to case drawing on specifications to receive the maximum length of mounting screw.
(e) Recommended wires of Modular units are shown as below.

AWG1816141210
Rated Current of Equipment (Amp)6A6-10A10-16A16-25A25-32A32-40A
Cross-section of Lead( mm^2 )0.751.001.52.54
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more strips should not exceed 80% of current rating.

8

Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

(f) For other information about the products, please refer to www.meanwell.com for details.

Installation Manual

(3) PCB Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Recommended wires of PCB units are shown as below.

AWG1816141210
Rated Current of Equipment (Amp)6A6-10A10-16A16-25A25-32A32-40A
Cross-section of Lead( mm^2 )0.751.001.52.54
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more strips should not exceed 80% of current rating.

8

6

Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

(e) At least 5mm insulation distance on the bottom of PCB units should be kept and a Mylar film should be added between the units and the system. In addition, keep enough insulation distance of 15mm around the PCB units.
(f) PCB units greater than 120W may require a forced air/fan for cooling. Please refer to specifications to receive a minimum air intensity and air-flow direction.
(g) For other information about the products, please refer to www.meanwell.com for details.

(4) Adapter Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Before attaching the DC plug of an adaptor to equipment, please unplug the adaptor from the AC power and verify the unit is within the voltage and current rating on the equipment.
(e) Keep the linkage between the adaptor and its power cord tightly as well as connecting the DC plug to equipment properly.
(f) Protect the power cord of adaptors from being trodden on or being squashed.
(g) An approved power cord of an adaptor should greater or equal to SVT, 3G×18AWG or H03VV-F, 3G×0.75mm2.
(h) If the final equipment is not used for long period of time, disconnect the equipment from adaptors to avoid being damaged by voltage peaks or lightning strike.
(i) For other information about the products, please refer to www.meanwell.com for details.

- User Manual

NMP series:

http://www.meanwell.com/webapp/product/search.aspx?prod=NMP1K2&pdf=Tk1QLUUucGRm&a=4

● Warning / Caution !!

(1) Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do not remove the case of the power supply by yourself! Please do not install the units in places with high moisture or near the water.
(2) Please do not install the units in places with high ambient temperature or near fire source. The maximum ambient temperature, please refer to their specifications.
(3) Output current and output wattage must not exceed the rated values on specifications.
(4) To avoid risk of electric shock, for class I products, the ground (FG) must be connected to protective earth.
(5) The Enclosed, Modular and PCB units are designed in accordance with EMC regulations and the related test reports are available by request. Since they are belong to component power supplies and will be installed inside system enclosure, when they are integrated into a system, the EMC characteristics of the end system must be re-verified again.

Manufacturer :

MEAN WELL ENTERPRISES Co., LTD.

No.28, Wuquan 3rd Rd., Wugu Dist.,

New Taipei City 24891, Taiwan

Tel: +886-2-2299-6100

Web: www.meanwell.com

Branch Office :

China

MEAN WELL (GUANGZHOU)

ENTERPRISES Co., LTD.

2F, A Building, Yuean Industry Park,

Huangcun, Dongpu Yown, Tianhe

District, Gungzhou, China

Post Code:510660

Tel: +86-20-2887-1200

Web: www.meanwell.com.cn

U.S.A.

MEAN WELL USA, INC.

44030 Fremont Blvd., Fremont,

CA 94538, U.S.A.

Tel: +1-510-683-8886

Web: www.meanwellusa.com

Europe

MEAN WELL EUROPE B.V.

Langs de Werf 8, 1185XT

Amstelveen, The Netherlands

Tel: +31-20-758-6000

Web: www.meanwell.eu

Declaration of China RoHS Conformity

In order to reduce the impacts on the environment and take the more responsibility for protecting the earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products.

Environment Friendly Use Period Label

Mean Well RPT-160C - Environment Friendly Use Period Label - 1Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly Use Period of Electronic Information Products Appendix B, adopting table look-up to verify the Environment Friendly Use Period

Names and Contents of Hazardous Substances Lists

Part NameHazardous Substances
Lead(Pb)Mercury(Hg)Cadmium(Cd)Hexavalent chromium( Cr^6+ )Polybrominated biphenyls(PBB)Polybrominated diphenyl ethers(PBDE)
PCB and its componentsXOXOOO
Metal structure partsXOOOOO
Plastic structure partsOOOOOO
AccessoriesOOOOOO
CablesXOOOOO
O: The concentration of the hazardous substances within the homogeneous material of that product is less than the concentration limits set by GB/T 26572-2011.X: The concentration of the hazardous substances within the homogeneous material of that product is over the concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.