Product TypeMedical Switching Power Supply
BrandMean Well
ModelRPT-160A
CategoryUncategorized (PCB Type)
Form FactorPCB (Printed Circuit Board) Mount
FamilyRPT
Safety StandardsDesigned as component power supply; EMC reports available on request
Mounting OrientationStandard orientation recommended; deviations may require output current derating
Ambient TemperatureRefer to specifications for maximum; high ambient requires derating
Cooling RequirementUnits >120W may need forced air/fan; ensure unobstructed ventilation
Clearance from Heat Sources10-15 cm clearance from adjacent heat sources
Insulation Distance (PCB Bottom)Minimum 5 mm; add Mylar film if needed; 15 mm around PCB units
Wire Gauge RecommendationAWG 18 to 10 depending on rated current (6A to 40A); cross-section 0.75 to 4 mm²
Grounding RequirementFor Class I products, FG must be connected to protective earth
Electrical Hazard WarningRisk of shock; do not remove case; only qualified technicians should service
Installation PrecautionDisconnect from utility before maintenance; prevent inadvertent reconnection
ManufacturerMean Well Enterprises Co., Ltd., Taiwan
Contactwww.meanwell.com | +886-2-2299-6100
China RoHS ComplianceConforms to China RoHS; hazardous substances list available in manual

Frequently Asked Questions - RPT-160A Mean Well

What type of power supply is the Mean Well RPT-160A?
The RPT-160A is a medical switching power supply in the PCB form factor, part of the RPT family.
What are the installation precautions for the RPT-160A?
Before installation, disconnect the system from the utility and ensure it cannot be reconnected inadvertently. Follow mounting orientation guidelines and maintain proper clearance from heat sources.
What wire gauge should I use for the RPT-160A?
Recommended wire gauges range from AWG 18 (for up to 6A) to AWG 10 (for up to 40A). For multiple strips, do not exceed 80% of the rated current.
Does the RPT-160A require forced cooling?
PCB units greater than 120W may require forced air or a fan. Keep ventilation holes unobstructed and maintain a 10-15 cm clearance from heat sources.
What are the insulation distance requirements for the RPT-160A?
Keep at least 5 mm insulation distance on the bottom of the PCB. Add a Mylar film if needed. Maintain 15 mm clearance around the PCB unit.
Can I mount the RPT-160A in any orientation?
Mounting orientations other than standard may increase internal component temperature and require output current derating. Refer to the specification sheet for optimum mounting position.
Is the RPT-160A compliant with safety standards?
The unit is designed as a component power supply. EMC test reports are available upon request. When integrated into a system, the end system's EMC must be re-verified.
What should I do if the power supply fails?
All failures should be examined by a qualified technician. Do not remove the case yourself due to risk of electric shock and energy hazard.
How do I ground the RPT-160A?
For Class I products, the ground (FG) must be connected to protective earth to avoid risk of electric shock.
Where can I find more information about the RPT-160A?
Visit the Mean Well website at www.meanwell.com or contact their Taiwan office at +886-2-2299-6100.

User questions about RPT-160A Mean Well

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual RPT-160A - Mean Well and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RPT-160A by Mean Well.

USER MANUAL RPT-160A Mean Well

● Type : Medical Switching Power Supply

(1) Enclosed (Families: MSP)
(2) Modular (Families: MP, NMP)
(3) PCB (Families: MPS, MPD, MPT, MQ, RPS, RPD, RPT, RPTG, NEM, PM)
(4) Adaptor (Families: GSM, MES)

- Installation

(1) Enclosed Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Keep enough insulation distance between mounting screws and internal components of Enclosed units. Please refer to case drawing on specifications to receive the maximum length of mounting screw.
(e) Recommended wires of Enclosed units are shown as below.

AWG1816141210
Rated Current of Equipment (Amp)6A6-10A10-16A16-25A25-32A32-40A
Cross-section of Lead( mm^2 )0.751.001.52.54
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more strips should not exceed 80% of current rating.

8

Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

(f) For other information about the products, please refer to www.meanwell.com for details.

(2) Modular Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Keep enough insulation distance between mounting screws and internal components of Modular units. Please refer to case drawing on specifications to receive the maximum length of mounting screw.
(e) Recommended wires of Modular units are shown as below.

AWG1816141210
Rated Current of Equipment (Amp)6A6-10A10-16A16-25A25-32A32-40A
Cross-section of Lead( mm^2 )0.751.001.52.54
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more strips should not exceed 80% of current rating.

8

Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

(f) For other information about the products, please refer to www.meanwell.com for details.

Installation Manual

(3) PCB Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Recommended wires of PCB units are shown as below.

AWG1816141210
Rated Current of Equipment (Amp)6A6-10A10-16A16-25A25-32A32-40A
Cross-section of Lead( mm^2 )0.751.001.52.54
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more strips should not exceed 80% of current rating.

8

6

Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

(e) At least 5mm insulation distance on the bottom of PCB units should be kept and a Mylar film should be added between the units and the system. In addition, keep enough insulation distance of 15mm around the PCB units.
(f) PCB units greater than 120W may require a forced air/fan for cooling. Please refer to specifications to receive a minimum air intensity and air-flow direction.
(g) For other information about the products, please refer to www.meanwell.com for details.

(4) Adapter Type

(a) Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
(d) Before attaching the DC plug of an adaptor to equipment, please unplug the adaptor from the AC power and verify the unit is within the voltage and current rating on the equipment.
(e) Keep the linkage between the adaptor and its power cord tightly as well as connecting the DC plug to equipment properly.
(f) Protect the power cord of adaptors from being trodden on or being squashed.
(g) An approved power cord of an adaptor should greater or equal to SVT, 3G×18AWG or H03VV-F, 3G×0.75mm2.
(h) If the final equipment is not used for long period of time, disconnect the equipment from adaptors to avoid being damaged by voltage peaks or lightning strike.
(i) For other information about the products, please refer to www.meanwell.com for details.

- User Manual

NMP series:

http://www.meanwell.com/webapp/product/search.aspx?prod=NMP1K2&pdf=Tk1QLUUucGRm&a=4

Installation Manual

● Warning / Caution !!

(1) Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do not remove the case of the power supply by yourself! Please do not install the units in places with high moisture or near the water.
(2) Please do not install the units in places with high ambient temperature or near fire source. The maximum ambient temperature, please refer to their specifications.
(3) Output current and output wattage must not exceed the rated values on specifications.
(4) To avoid risk of electric shock, for class I products, the ground (FG) must be connected to protective earth.
(5) The Enclosed, Modular and PCB units are designed in accordance with EMC regulations and the related test reports are available by request. Since they are belong to component power supplies and will be installed inside system enclosure, when they are integrated into a system, the EMC characteristics of the end system must be re-verified again.

Manufacturer :

MEAN WELL ENTERPRISES Co., LTD.

No.28, Wuquan 3rd Rd., Wugu Dist.,

New Taipei City 24891, Taiwan

Tel: +886-2-2299-6100

Web: www.meanwell.com

Branch Office :

China

MEAN WELL (GUANGZHOU)

ENTERPRISES Co., LTD.

2F, A Building, Yuean Industry Park,

Huangcun, Dongpu Yown, Tianhe

District, Gungzhou, China

Post Code:510660

Tel: +86-20-2887-1200

Web: www.meanwell.com.cn

U.S.A.

MEAN WELL USA, INC.

44030 Fremont Blvd., Fremont,

CA 94538, U.S.A.

Tel: +1-510-683-8886

Web: www.meanwellusa.com

Europe

MEAN WELL EUROPE B.V.

Langs de Werf 8, 1185XT

Amstelveen, The Netherlands

Tel: +31-20-758-6000

Web: www.meanwell.eu

Declaration of China RoHS Conformity

In order to reduce the impacts on the environment and take the more responsibility for protecting the earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products.

Environment Friendly Use Period Label

Mean Well RPT-160A - Environment Friendly Use Period Label - 1Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly Use Period of Electronic Information Products Appendix B, adopting table look-up to verify the Environment Friendly Use Period

Names and Contents of Hazardous Substances Lists

Part NameHazardous Substances
Lead(Pb)Mercury(Hg)Cadmium(Cd)Hexavalent chromium( Cr^6+ )Polybrominated biphenyls(PBB)Polybrominated diphenyl ethers(PBDE)
PCB and its componentsXOXOOO
Metal structure partsXOOOOO
Plastic structure partsOOOOOO
AccessoriesOOOOOO
CablesXOOOOO
O: The concentration of the hazardous substances within the homogeneous material of that product is less than the concentration limits set by GB/T 26572-2011.X: The concentration of the hazardous substances within the homogeneous material of that product is over the concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.