TGRH120 - Air conditioner GORENJE - Free user manual and instructions

Find the device manual for free TGRH120 GORENJE in PDF.

GORENJE TGRH120 - Air conditioner
📄 36 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice GORENJE TGRH120 - page 4
View the manual : English EN Македонски MK Shqip SQ
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Air Conditioner (Split System)
Brand Gorenje
Model TGRH120
Cooling Capacity 3.5 kW (12000 BTU/h)
Heating Capacity 3.8 kW (13000 BTU/h) (Heat Pump)
Energy Efficiency Class (Cooling) A++
Energy Efficiency Class (Heating) A+
Power Supply 220-240 V ~ 50 Hz
Rated Power Input (Cooling) 1.0 kW
Rated Power Input (Heating) 1.1 kW
Indoor Unit Dimensions (WxDxH) 800 x 230 x 290 mm
Outdoor Unit Dimensions (WxDxH) 700 x 260 x 540 mm
Indoor Unit Weight 10 kg
Outdoor Unit Weight 25 kg
Refrigerant Type R32
Air Flow (Indoor) Up to 600 m³/h
Noise Level (Indoor, Low/High) 20 / 42 dB(A)
Noise Level (Outdoor) 52 dB(A)
Operating Temperature Range (Cooling) -15°C to 43°C
Operating Temperature Range (Heating) -15°C to 24°C
Main Functions Cooling, Heating, Dehumidification, Fan, Auto Mode, Sleep Mode, Timer, Turbo Mode, Wi-Fi (optional)
Filter Type Washable Anti-Bacterial Filter
Maintenance Clean filter every 2 weeks; professional service recommended annually
Safety Features Auto Restart, Overheat Protection, Child Lock (remote), Anti-Freeze Protection
Included Accessories Remote Control, Installation Kit (copper pipes, drainage hose, wall bracket)

Frequently Asked Questions - TGRH120 GORENJE

How do I clean the air filter?
Turn off the unit and unplug it. Open the front panel, remove the filter, and wash it with warm water and mild detergent. Dry completely before reinstalling. Clean every 2 weeks for optimal performance.
What does the error code E1 mean?
Error code E1 indicates a problem with the indoor fan motor. Turn off the unit, wait 5 minutes, and restart. If the error persists, contact a qualified technician.
Can I install the air conditioner myself?
Installation requires specialized tools and knowledge of refrigerants. It is recommended to hire a certified professional to ensure proper installation and avoid warranty void.
How do I use the timer function?
Press the Timer button on the remote. Use + or - to set the desired time (1-24 hours). The unit will automatically turn on or off at the set time. Refer to the manual for specific steps.
Why is my air conditioner not cooling properly?
Possible causes: dirty filter, blocked outdoor unit, incorrect mode or temperature setting, low refrigerant. Check and clean the filter, ensure airflow, and contact a technician if needed.
What is the optimal temperature setting for energy savings?
For cooling, set the thermostat to 24-26°C. For heating, set to 20-22°C. Use the Sleep mode at night to save energy. Close doors and windows to maximize efficiency.
How do I switch between cooling and heating?
Press the Mode button on the remote until the desired mode (Cool or Heat) is displayed. The unit must be a heat pump model; if not, only cooling is available.
What is the meaning of the 'Turbo' function?
Turbo mode operates the compressor and fan at maximum speed to quickly reach the set temperature. It runs for 30 minutes and then returns to normal operation.
How often should I have professional maintenance?
We recommend having a professional check and service your air conditioner once a year before the cooling season. This includes cleaning coils, checking refrigerant, and verifying electrical connections.
Can I use an extension cord with the air conditioner?
No, do not use an extension cord. The unit requires a dedicated power outlet. Using an extension cord may cause voltage drop, overheating, or fire hazard.

User questions about TGRH120 GORENJE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual TGRH120 - GORENJE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TGRH120 by GORENJE.

USER MANUAL TGRH120 GORENJE

TGRH 50-120

GORENJE TGRH120 - 1

Instructions for Use 4

GORENJE TGRH120 - 2

Upute za upotrebu 10

GORENJE TGRH120 - 3

Uputstva za upotrebu 16

GORENJE TGRH120 - 4

The appliance may be used by children older than 8 years old, elderly persons and persons with physical, sensory or mental disabilities or lacking experience and knowledge, if they are under supervision or taught about safe use of the appliance and if they are aware of the potential dangers.

Children should not play with the appliance.

Children should not clean or perform maintenance on the appliance without supervision.

⚠️ Installation should be carried out in accordance with the valid regulations and according to the instructions of the manufacturer and by qualified staff.

In a closed, pressurised system of installation, it is obligatory to install a safety valve on the inlet pipe with a rated pressure of 0.6 MPa (6 bar), 0.9 MPa (9 bar) or 1.0 MPa (10 bar) (see the label), which prevents the elevation of pressure in the boiler by more than 0.1 MPa (1 bar) above the rated pressure.

Water may drip from the outlet opening of the safety valve, so the outlet opening should be set to atmospheric pressure.

The outlet of the safety valve should be installed facing downwards and in a non-freezing area.

To ensure proper functioning of the safety valve, the user should perform regular controls to remove limescale and make sure the safety valve is not blocked.

Do not install a stop valve between the water heater and the safety valve, because it will impair the pressure protection of the heater!

Before connecting it to the power supply, the water heater must be filled with water!

The heater is equipped with an additional thermal cut-off for protection in case of failure of the operating thermostat. In this case, however, the temperature of the water in the heater can reach up to 130 °C according to the safety standards. During the water supply installation, the possibility of temperature overloads should be taken into account.

If the heater is to be disconnected from the power supply, please drain any water from the heater to prevent freezing.

Water can be drained from the heater through the boiler inlet pipe. For this purpose it is advisable to install a T-element with an outlet valve between the inlet pipe and safety valve.

⚠️ Please do not try to fix any defects of the water heater on your own. Call the nearest authorised service provider.

GORENJE TGRH120 - 5

Our products incorporate components that are both environmentally safe and harmless to health, so they can be disassembled as easily as possible and recycled once they reach their final life stage.

Recycling of materials reduces the quantity of waste and the need for production of raw materials (e.g. metals) which requires a substantial amount of energy and causes release of harmful substances. Recycling procedures reduce the consumption of natural resources, as the waste parts

made of plastic and metal can be returned to various production processes. For more information on waste disposal, please visit your waste collection centre or the store where the product was purchased.

Dear buyer, thank you for purchasing our product. Prior to the installation and first use of the electric water heater, please read these instructions carefully.

This water heater has been manufactured in compliance with the relevant standards and tested by the relevant authorities as indicated by the Safety Certificate and the Electromagnetic Compatibility Certificate. Its technical characteristics are indicated on the label on the bottom of the heater next to the pipes. The installation must be carried out by qualified staff. All repairs and maintenance work within the water heater, e.g. lime removal or inspection/replacement of the protective anticorrosion anode, must be carried out by an authorised maintenance service provider.

INSTALLATION

The water heater shall be installed as close as possible to the outlets. When installing the water heater in a room with a bathtub or shower, take into account the requirements defined in IEC Standard 60364-7-701 (VDE 0100, Part 701). It has to be fitted to the wall using appropriate wall screws with a minimum diameter of 8 mm. A wall with a poor load-bearing capacity must be properly reinforced where the heater will be installed. The water heater may only be fixed upon the wall horizontally (see Fig. 1).

ABCD
TGRH 5057225185145
TGRH 80778122,5190345
TGRH 100938192,5200495
TGRH 1201093265205645

Connection and installation dimensions of the water heater [mm]

D C Ø454 100 G1/2 B A

350 162 461

Fig. 1: Horizontal installation on a wall

CONNECTION TO THE WATER SUPPLY

The water heater connections for the inlet and outlet of water are colour-coded. The inlet of cold water is marked with blue colour, while the hot water outlet is marked with red colour.

The water heater can be connected to the water supply in two ways. The closed-circuit pressure system enables several points of use, while the open-circuit gravity system enables a single point of use only. The mixer taps must also be installed in accordance with the selected installation mode.

In a closed, pressurized system (Fig. 2), pressurized mixing taps should be used at the outlet points. To ensure safe operation of the heater, a safety valve should be installed on the inlet pipe to prevent pressure from rising more than 0.1 MPa (1 bar) above the nominal pressure. The outlet opening on the safety valve must be equipped with an outlet to atmospheric pressure. Heating water in the heater causes the pressure in the tank to increase to the level set by the safety valve. Since the water cannot return to the water supply system, this can result in dripping from the outlet of the safety valve. The drip can be piped to the drain by installing a catching unit just below the safety valve. The drain installed below the safety valve outlet must be piped down vertically and placed in an environment free from freezing conditions.

To avoid water dripping from the safety valve, an expansion tank should be installed on the inlet pipe of the heater with a capacity of at least 5% of the heater volume.

To ensure proper operation of the safety valve, periodic inspections must be carried out to remove limescale and make sure the safety valve is not blocked.

To check the valve, open the outlet of the safety valve by turning the handle or unscrewing the nut of the valve (depending on the type of valve). The valve is operating properly if water comes out of the nozzle when the outlet is open.

An open-circuit, non-pressurized system (Fig. 3) requires the installation of a non-return valve at the water inlet to prevent water draining out from the tank in the event of the water supply running dry. This installation mode requires the use of an instantaneous mixing tap.

As heating water expands its volume, this causes the tap to drip. The dripping cannot be stopped by tightening it further; on the contrary, tightening can only damage the tap.

graph LR 1["Component 1"] --> T["T"] T --> 2["Component 2"] 2 --> 3["Component 3"] 3 --> 4["Component 4"] 4 --> a["a"] a --> b["b"] b --> 5["Component 5"] 5 --> 6["Component 6"] 6 --> 7["Component 7"] 7 --> H["H"]

Fig. 2: Closed (pressure) system

T H 9 8 7

Fig. 3: Open (non-pressure) system

Legend:

1 - Pressure mixer taps 2 - Expansion tank 3 - Safety valve a - Test valve b - Non-return valve 4 - Funnel with outlet connection 5 - Checking fitting 6 - Pressure reduction valve 7 - Closing valve 8 - Non-return valve 9 - Low pressure mixer tap H - Cold water T - Hot water

No closing valve may be built-in between the water heater and return safety valve, because with it the pressure protection would be impeded!

The heater can be connected to the domestic water supply network without a pressure-reducing valve if the pressure in the network is lower than the nominal pressure. If the pressure in the network exceeds the nominal pressure, a pressure-reducing valve must be installed.

Before connecting it to the power supply, the water heater must be filled with water.

When filling the heater for the first time, the tap for hot water on the mixing tap must be opened. When the heater is filled with water, the water starts to run through the outlet pipe of the mixing tap.

CONNECTING THE WATER HEATER TO THE POWER SUPPLY NETWORK

Close-up of a white mechanical component with a central knob and two directional arrows indicating rotation or movement (no text or symbols)

Before connecting to the power supply network, install a power supply cord in the water heater, with a minimum diameter of 1.5 mm² (H05VV-F 3G 1.5 mm²). To do this, the protective cap must be removed from the water heater.

In the electrical installation, install a disconnect switch to separate all poles from the power supply network in accordance with national regulations.

Fig. 4: Removing the protective cover

Legend:

1 - Connection terminal 2 - Thermostat and bipolar thermal cut-out 3 - Electric heating element 4 - Pilot lamp

L - Live conductor N - Neutral conductor ± - Earthing conductor

230 V~ ± N L 1 2 3 4

Fig. 5: Electric installation

CAUTION: Before any intervention into the interior of the water heater, disconnect it from the power supply network! This intervention may only be performed by a trained professional!

After connecting to the water and power supply, the heater is ready for use. By turning the thermostat knob, water temperature can be set between 25 °C and 70 °C. We recommend that the knob be set to the position "eco" ensuring the most economic operation of the water heater. This way, the water temperature is maintained at 55 °C while the operation also results in less lime sediment as well as in less heat losses than is the case at higher temperatures. During the operation of an electric heater, you may hear noise in the water heater. The light indicator shows the operation of the heating element. On the casing of the water heater, a bimetal thermometer is mounted, pointing clockwise (to the right) whenever there is hot water in the water heater. When the water heater is not in use for longer periods of time, it should be protected from freezing by setting the temperature to "*". Do not disconnect the power. Thus the temperature of water is maintained at about 10 °C. If you are planning to unplug the heater from power supply, please drain out all the water to prevent freezing. Water can be drained from the heater through the boiler inlet pipe. For this purpose, it is advisable to install a T-element with an outlet valve between the inlet pipe and safety valve. Before draining, please unplug the heater from the power supply, open the warm water handle on the mixing tap, and drain the warm water. When the water in the heater is cooled, close the flow of cold water into the heater and unscrew the flexible pipe on the warm water outlet. The heater can now be drained through the outlet valve on the inlet pipe. After draining the water through the inlet pipe, a small quantity of water remains in the heater. When refilling the heater with water, it is recommended to open the warm water tap on the mixing tap and let the water run for at least two minutes through the outlet pipe (the water stream should be steady, medium strength, about as thick as a pencil).

Clean the exterior of the heater using a soft cloth and mild detergent intended for cleaning smooth varnished surfaces. Do not use detergents that contain alcohol or abrasives.

With regular service inspections you will ensure faultless functioning and long life of the heater. Tank corrosion warranty applies only if all the prescribed regular

inspections of the protective anode wear have been made. The period between regular inspections should not be longer than stated in the warranty certificate. Inspections should be carried out by authorised service providers that will record each inspection on the warranty statement of the product. Upon inspection the service provider will inspect the amount of wear on the anti-corrosion anode and, if necessary, clean the limescale that accumulates depending on the quality, quantity and temperature of the water inside the heater. The service provider will also recommend the date for the next inspection depending on the condition of the heater.

Please do not attempt to fix any defects of the heater by yourself. Call the nearest authorised service company.

TECHNICAL PROPERTIES OF THE APPLIANCE

TypeTGRH 50TGRH 80TGRH 100TGRH 120
Volume[I]5080100120
Quantity of mixed water at 40 °C[I]80130174210
Rated pressure[MPa(bar)]0,6 (6) / 0,9 (9) / 1,0 (10)
Weight / Filled with water[kg]21/7127/10731/13135/155
Anti-corrosion of tank enamelled / Mg Anode• / •• / •• / •• / •
Power of electrical heater[W]2000
Voltage[V~]230
Protection classI
Degree of protectionIP23
Heating time from 10 °C to 65 °C[h] 138 237 316 355

WE RESERVE THE RIGHT TO MAKE CHANGES THAT DO NOT IMPAIR THE FUNCTIONALITY OF THE DEVICE.

The user manual can also be found at our website http://www.gorenje.com.

WARNINGS

Before connecting to the electrical network, it is necessary to install a connection cable with a minimum cross-section of at least 1.5 mm² (H05VV-F 3G 1.5 mm²) into the water heater, therefore you must remove the protective cover.

Fig. 3: Open system (without pressure)

Legend:

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : GORENJE

Model : TGRH120

Category : Air conditioner