CSB604 - Surge protector CyberPower - Free user manual and instructions
Find the device manual for free CSB604 CyberPower in PDF.
| Product Type | Surge Protector Power Strip |
| Brand | CyberPower |
| Model | CSB604 (also CSB606/CSB606W) |
| Number of Outlets | 6 Standard Outlets |
| Surge Protection Rating | 900 Joules |
| Electrical Rating | 125 V / 15 A / 1875 W |
| UL Clamping Voltage | UL 1449 3rd / 500 V (H-N, H-G, N-G) |
| Maximum Surge Current | 15,000 A (H-N, H-G, N-G) |
| Response Time | Less than 1 nanosecond |
| Attenuation | Up to 32 dB |
| Circuit Breaker | Resettable 15 Amp |
| EMI/RFI Filtration | 150 kHz to 100 MHz |
| Power Source | Standard grounding wall receptacle (120V) |
| Usage Location | Indoors only, dry locations |
| Certifications | FCC Part 15 Class B |
| Technical Support | Toll-Free: 1-877-297-6937 |
| Safety Warning | Contains BPA and styrene (California Prop 65) |
Frequently Asked Questions - CSB604 CyberPower
User questions about CSB604 CyberPower
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Surge protector in PDF format for free! Find your manual CSB604 - CyberPower and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CSB604 by CyberPower.
USER MANUAL CSB604 CyberPower
CSB604/CSB606/CSB606W
USER MANUAL

Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com
FEATURES
1. ON/OFF Reset Control Switch and Circuit Breaker
Controls power to all outlets. The switch is also a 15 A breaker. When an overload occurs, it will automatically switch off. To resume operation, ensure the overload condition is removed and reset the surge protector by switching the unit ON.
2. Six Standard Outlets
SURGE PROTECTOR INSTRUCTIONS
- Set power switch into the "OFF" position. Plug the surge protector into a standard grounding wall receptacle by fully inserting the plug and ensure that there are no exposed conductors.
- Make sure electronic equipment is turned off before plugging into the surge protector outlets. Do not use extension cords to connect equipment to the surge protector.
- Set the power switch into the "RESET" position. The surge protector will now be providing power and surge protection.
- Connected equipment can now be turned on.
SPECIFICATIONS
Model Number: CSB604/CSB606/CSB606W
Outlets: 6 Standard Outlets
Surge Protection: 900 Joules
Electrical Rating: 125 V / 15 A / 1875 W
UL Clamping Voltage: UL 1449 3rd / 500 V
(H-N, H-G, N-G)
3 AC Lines Protected: H-N: 15,000 A,
H-G: 15,000 A,
N-G: 15,000 A
Response Time: Less than 1 nanosecond
Attenuation: Up to 32 dB
Circuit Breaker: Resettable 15 Amp
EMI/RFI Filtration: 150 kHz to 100 MHz
△WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene (ABS), which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK:
Use only in dry locations and only indoors.
DO NOT plug into another relocatable power tap.
DO NOT "daisy chain" surge protectors.
DO NOT use with any aquarium equipment
DO NOT use if properly grounded outlets are not available.
DO NOT install this device if there is less than 10 meters (30 feet) of wire between
the electrical outlet and electrical service panel.
DO NOT use for medical or life support equipment. This device features an internal
useful life, but it will maintain unprotected power to the load.
TROUBLESHOOTING
If the ON/OFF is switched OFF, the 15 Amp circuit breaker may have tripped. Examine your connected equipment and remove the device that is overloading the circuit. Then, turn the ON/OFF switch back to RESET.
FOR MORE INFORMATION
Visit CyberPowerSystems.com for more information regarding:
• Product information and certifications
• Product warranty
• Connected equipment guarantee
TECHNICAL SUPPORT
Visit: CyberPowerSystems.com/support
Toll-Free: 1-877-297-6937
© 2022 Cyber Power Systems (USA), Inc. All rights reserved.
All other trademarks are the property of their respective owners.

CONFORMANCE APPROVALS
This device complies with Part 15 of the FCC Rules
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generated, close, and can't have been frequently charged and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
+ Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver. - General the equipment into an pellet on a circuit different from
that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.