CyberPower MP1020SEC - Surge protector

MP1020SEC - Surge protector CyberPower - Free user manual and instructions

Find the device manual for free MP1020SEC CyberPower in PDF.

📄 3 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice CyberPower MP1020SEC - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Surge Protector with USB Charging
Model Number MP1020SEC (P403UBGY)
Outlets 4 Standard Grounded Outlets
USB Ports 2 USB Charging Ports (5V/2.4A total)
Power Cord Length 3 ft
Electrical Rating 125V/15A/1875W
Surge Protection 500 Joules
UL Clamping Voltage UL 1449 4th, 800V (L-N)
Maximum Peak Current 15,000A
Response Time Less than 1 nanosecond
Circuit Breaker Resettable 15 Amp
Plug Type Low Profile
Indicators Protected LED Indicator
Switch ON/OFF Reset Control Switch with Circuit Breaker
Power Supply AC line powered
Color White/Black (unconfirmed)
Material ABS plastic (contains BPA and styrene)
Protection Features Automatic shutdown when surge protection is depleted
Safety Certifications FCC Part 15 Class B, UL 1449
Cleaning and Maintenance Wipe with dry cloth; do not use liquids
Repairability Non-repairable; replace after surge protection is depleted
Warranty Refer to product warranty on CyberPowerSystems.com

Frequently Asked Questions - MP1020SEC CyberPower

What should I do if the Protected LED does not light up?
If the Protected LED does not light, the surge protector's AC lines are no longer protected from surges. This may indicate that the unit has experienced a surge beyond its limits. Replace the surge protector immediately.
Can I charge my phone using the USB ports?
Yes, the USB ports provide 5V/2.4A total for charging devices like phones and tablets. They are surge protected but do not transfer data.
What does the ON/OFF switch do?
The ON/OFF switch controls power to all outlets and acts as a 15A circuit breaker. If overloaded, it will trip and cut power. Reset by switching ON after removing the overload.
Is it safe to use this surge protector with an aquarium?
No, do not use this device with any aquarium equipment to reduce the risk of electric shock.
Can I plug this surge protector into another power strip?
No, do not plug this surge protector into another relocatable power tap or daisy chain surge protectors.
What is the electrical rating of this surge protector?
The electrical rating is 125V/15A/1875W. Do not exceed these limits.
What should I do if the surge protector stops working after a power surge?
If the surge protector has been overloaded, the internal protection will disconnect the surge protective component. The unit may still provide power but will no longer protect against future surges. Replace it.
How do I know if my outlet is properly grounded?
The Protected LED will illuminate when the surge protector is plugged into a properly grounded outlet. If it does not light, try a different outlet or consult an electrician.
Can I use this device for medical equipment?
No, this device is not intended for medical or life support equipment. It may lose surge protection at the end of its life and leave equipment unprotected.
How long is the warranty on this surge protector?
Visit CyberPowerSystems.com for product warranty and connected equipment guarantee details. The warranty typically covers defects but not surge-related failure after protection is depleted.

User questions about MP1020SEC CyberPower

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Surge protector in PDF format for free! Find your manual MP1020SEC - CyberPower and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MP1020SEC by CyberPower.

USER MANUAL MP1020SEC CyberPower

Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com

FEATURES

1. ON / OFF Reset Control Switch and Circuit Breaker

Controls power to all outlets. The switch is also a 15 A breaker. When an overload occurs, it will automatically switch off. To resume operation, ensure the overload condition is removed and reset the surge protector by switching the unit ON.

2. Protected LED Indicator

Illuminated when the surge protection feature is working properly.

3. Standard Grounded Outlets (4)

4. USB Charging Ports\* (2)

Connect and charge up to two (2) USB devices using the surge protected USB charging ports.
*USB outlets cannot be used as a USB hub. This device does not transfer data.

SPECIFICATIONS

Model Number: P403UBGY

Outlets: Standard Grounded Outlets (4), USB Charging Ports (2)

Power Cord Length: 3 ft

Plug Type: Low Profile

Surge Protection: 500 Joules

Electrical Rating: 125 V / 15 A / 1875 W

USB Charging Rating: 5 V / 2.4 A Total

UL Clamping Voltage: UL 1449 4th

800 V (L-N)

Maximum Peak Current: 15,000 A

1 AC Line Protected: L-N: 15.000 A

(The maximum surge possible on

household wiring is 6,000 volts)

Response Time: Less than 1 nanosecond

Circuit Breaker: Resettable 15 Amp

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK:

Use only in dry locations and only indoors

DO NOT plug into another relocatable power tap.

DO NOT "daisy chain" surge protectors.

DO NOT use with any aquarium equipment.

DO NOT use if properly grounded outlets are not available.

DO NOT install this device if there is less than 10 meters (30 feet) of wire between the electrical outlet and electrical service panel.

DO NOT use for medical or life support equipment. This device features an internal protection that will disconnect the surge protective component at the end of its useful life, but it will maintain unprotected power to the load.

△WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene (ABS), which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.

FOR MORE INFORMATION

Visit CyberPowerSystems.com for more information regarding:

• Product information and certifications

- Product warranty

• Connected equipment guarantee

TROUBLESHOOTING

If the grounded indicator does not light when you plug in the surge protector, move the surge protector to a different grounded three-prong AC outlet. If it still does not light, return the product to the retailer for assistance. If the surge protector appears to be working properly, your outlets may not be properly grounded and need to be repaired by a professional electrician. If the grounded indicator turns off after a period of use, the surge protection has been depleted. Replace your surge protector.

If the protected indicator does not light, the surge protector's AC lines are no longer protected from surge. The surge protector may have received a power surge or spike beyond its specified limits that overloaded the protection circuitry and rendered it inactive. The surge protector has protected your connected equipment as designed, but it will not protect against future surges and spikes. It should be replaced.

TECHNICAL SUPPORT

Visit: CyberPowerSystems.com/support

Toll-Free: 1-877-297-6937

Hours of Operation: Monday - Friday: 7:00am - 6:00pm CST

© 2022 Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners.

CONFORMANCE APPROVALS This device complies with Part Operation is subject to the folk

Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against

harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected

- Consult the dealer or an experienced radio/TV technician for help.

WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

CyberPower®

YOUR ULTIMATE ALLY IN POWER

5-PORT USB CHARGING STATION

TR15UC30

USER MANUAL

DavonPeranse USB-C USB PD ① ②

Cyber Power Systems (USA), Inc.

4241 12th Avenue East, Suite 400 | Shakopee, MN 55379

CyberPowerSystems.com

FEATURES

  1. 1 USB-C charging port (30W PD)
  2. 4 USB-A charging ports (4.2A shared)
  3. 5-ft Power Cord
  4. Vertical Stand
  5. LED Power Indicator

4 x 1 x

SPECIFICATIONS

Model Number: TR15UC30

USB-C Charging Ports: 1

USB-A Charging Ports: 4

USB-C Output: 30W Power Delivery

5 V / 3 A,

9 V / 3 A,

15 V / 2 A

20 V / 1.5 A)

USB-A Output: 5 V / 4.2 A

Power Cord Length: 5 ft

Plug Type: Detachable

Input: 100-240 VAC

△WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene (ABS), which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK:

Use only in dry locations and only indoors.

DO NOT plug into another relocatable power tap.

DO NOT "daisy chain" surge protectors.

DO NOT use with any aquarium equipment.

DO NOT use if properly grounded outlets are not available.

DO NOT install this device if there is less than 10 meters (30 feet) of wire between

the electrical outlet and electrical service panel.

DO NOT use for medical or life support equipment. This device features an internal protection that will disconnect the own protective component at the end of its

protection that will disconnect the surge protective component useful life, but it will maintain unprotected power to the load.

FOR MORE INFORMATION

Visit CyberPowerSystems.com for more information regarding:
• Product information and certifications
- Product warranty
• Connected equipment guarantee

TECHNICAL SUPPORT

Visit: CyberPowerSystems.com/support

Toll-Free: 1-877-297-6937

Hours of Operation: Monday - Friday: 7:00am - 6:00pm CST

© 2022 Cyber Power Systems (USA), Inc. All rights reserved.

All other trademarks are the property of their respective owners.

CyberPower MP1020SEC - FOR MORE INFORMATION - 1

CONFORMANCE APPROVALS

This device complies with Part 13 of the PCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limit for a Glass D digital device pursuant to Part 15 of the ECG Dules.

For a Class B digital device, pursuant to Part 15 of the PCC Rules. These limits are designed to provide reasonable protection against

harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from
    that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WARNING: Changes or modifications not expressly approved by the

party responsible for compliance could void the user's authority to operate the equipment.

CyberPower

YOUR ULTIMATE ALLY IN POWER

1-OUTLET USB CHARGING CORD (1 OUTLET & 2 USB PORTS)

GC106U

USER MANUAL
CyberPower 2.4A USB

Cyber Power Systems (USA), Inc.

4241 12th Avenue East, Suite 400 | Shakopee, MN 55379

CyberPowerSystems.com

FEATURES

1. Standard Grounded Outlet

2. USB Charging Ports\* (2)

Connect and charge up to two (2) USB devices using the surge protected USB charging ports. *USB outlets cannot be used as a USB hub. This device does not transfer data.

INSTRUCTIONS

  1. Plug the device into a standard grounding wall receptacle by fully inserting the plug and ensure that there are no exposed conductors.
  2. Make sure the electronic equipment is turned off before plugging into the device's outlet. Do not use extension cords to connect equipment to the device
  3. Connected equipment can now be turned on.

SPECIFICATIONS

Model Number: GC106U

Outlets: Standard Grounded Outlet (1), USB Charging Ports (2)

Power Cord Length: 6 ft

Plug Type: Low Profile

Electrical Rating: 125 V / 10 A / 1250 W

USB Charging Rating: 5 V / 2.4A Total

⚠ WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene (ABS), which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK:

Use only in dry locations and only indoors

DO NOT plug into another relocatable power tap.

DO NOT "daisy chain" surge protectors.

DO NOT use with any aquarium equipment.

DO NOT use if properly grounded outlets are not available.

DO NOT install this device if there is less than 10 meters (30 feet) of wire between the electrical outlet and electrical service panel.

DO NOT use for medical or life support equipment. This device features an internal protection that will disconnect the surge protective component at the end of its useful life, but it will maintain unprotected power to the load.

FOR MORE INFORMATION

Visit CyberPowerSystems.com for more information regarding:
• Product information and certifications
- Product warranty
• Connected equipment guarantee

TROUBLESHOOTING

If the grounded indicator does not light when you plug in the surge protector, move the surge protector to a different grounded three-prong AC outlet. If it still does not light, return the product to the retailer for assistance. If the surge protector appears to be working properly, your outlets may not be properly grounded and need to be repaired by a professional electrician. If the grounded indicator turns off after a period of use, the surge protection has been depleted. Replace your surge protector.

If the protected indicator does not light, the surge protector's AC lines are no longer protected from surge. The surge protector may have received a power surge or spike beyond its specified limits that overloaded the protection circuitry and rendered it inactive. The surge protector has protected your connected equipment as designed, but it will not protect against future surges and spikes. It should be replaced.

TECHNICAL SUPPORT

Visit: CyberPowerSystems.com/support

Toll-Free: 1-877-297-6937

Hours of Operation: Monday - Friday: 7:00am - 6:00pm CST

© 2022 Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners.

CyberPower MP1020SEC - TECHNICAL SUPPORT - 1

CONFORMANCE APPROVALS

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against

harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : CyberPower

Model : MP1020SEC

Category : Surge protector