Pick your language and provide your email: we'll send you a specifically translated version.
Product type Gas cooktop
Brand Fulgor Milano
Model CPH 402 G X
Number of burners 4
Gas type Natural gas (G20) / Butane/Propane (convertible)
Total power Approximately 8 kW
Dimensions (W x D x H) 600 x 510 x 50 mm
Weight Approximately 12 kg
Power supply Gas
Material Stainless steel
Ignition Integrated electric ignition
Safety Flame safety device (thermocouple)
Controls Rotary knobs
Cleaning Smooth stainless steel surface, easy cleaning with soft cloth and non-abrasive detergent
Spare parts Grills, injectors, thermocouples, knobs available from after-sales service
Repairability Estimated repairability index of 6/10
Warranty 2 years according to current legislation
Energy consumption Not applicable (gas)

Frequently Asked Questions - CPH 402 G X Fulgor Milano

How to install the CPH 402 G X cooktop?
Installation must be carried out by a qualified professional in accordance with current standards. Make sure the cutout in the worktop respects the dimensions indicated in the manual (600 x 510 mm). Connect the gas with a hose suitable for the type of gas used and check for leaks.
Can I convert the cooktop to use butane/propane gas?
Yes, the CPH 402 G X model is convertible. Replace the injectors with those provided in the conversion kit and adjust the primary air flow according to the instructions in the manual. Call a professional for this operation.
How to clean the burners and stainless steel surface?
Wait for the surface to cool down. Remove the grills and burner caps, wash them with warm soapy water. For stainless steel, use a soft cloth and a non-abrasive cleaning product. Avoid metal sponges to prevent scratching the surface.
What to do if a flame goes out during use?
The thermocouple safety device automatically cuts off the gas if the flame goes out. Wait a few minutes before relighting. If the problem persists, check that the burner ports are not clogged and that the thermocouple is clean.
The electric ignition does not work, what to do?
Check that the appliance is properly plugged into a grounded outlet. Clean the electrodes with a dry cloth. If the problem persists, contact after-sales service for a replacement.
What type of cookware to use?
Use pots with a flat and stable bottom, with a diameter suitable for the burner size. Avoid deformed or oversized containers that could destabilize the flame.
Does the cooktop get very hot during use?
Yes, stainless steel conducts heat. It is normal for the surface around the burners to become hot. Do not touch adjacent areas during and after use. Use pot holders for handles.
How to adjust the minimum flame on the burners?
Make sure the flame is set to the minimum position. If it is too high or too low, adjust the adjustment screw on the valve stem using a thin screwdriver, following the instructions in the manual.
Where to find spare parts for the CPH 402 G X model?
Spare parts (grills, injectors, thermocouples, knobs) are available from Fulgor Milano authorized after-sales service or from specialized appliance parts websites. Use the model number to identify the parts.
What is the estimated lifespan of this appliance?
With regular maintenance, a quality gas cooktop can last 15 to 20 years. Replacing wear parts (grills, injectors) can extend its lifespan.

User questions about CPH 402 G X Fulgor Milano

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Frying Pan in PDF format for free! Find your manual CPH 402 G X - Fulgor Milano and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CPH 402 G X by Fulgor Milano.

USER MANUAL CPH 402 G X Fulgor Milano

natural_image Simple geometric diagram showing a circle inscribed in a square frame (no text or symbols)

Allacciamento metallico rigido/semirigido

natural_image Line drawing of a hand using a tool to press or inspect a small object on a flat surface (no text or symbols)

Fig. 5

Fulgor Milano CPH 402 G X - Allacciamento metallico rigido/semirigido - 1

natural_image 3D mechanical component diagram showing a washer and housing assembly (no text or symbols)

Fulgor Milano CPH 402 G X - Allacciamento metallico rigido/semirigido - 2

natural_image 3D rendering of a mechanical lever assembly with a black head and lever handle (no text or symbols visible)

Fulgor Milano CPH 402 G X - Allacciamento metallico rigido/semirigido - 3

natural_image Technical line drawing of a mechanical component with a screwdriver inserted (no text or symbols)

Fulgor Milano CPH 402 G X - Allacciamento metallico rigido/semirigido - 4

natural_image Pure technical line drawing of a mechanical component without any text, numbers, or symbols

Fulgor Milano CPH 402 G X - Allacciamento metallico rigido/semirigido - 5

natural_image Mechanical lever mechanism diagram showing pivot, pivot shaft, and pivot wheel (no text or labels)

Fig. 6

CARATTERISTICHE UTILIZZATORI
BRUCIATORI GAS
ALIMENTAZIONE TIPO PRESSIONE mbar NORM.BRUCIATORE∅ INIETTORE 1/100PORTATA TERMICA NOMINALECONSUMO
Gas naturale G20 20rapido 129 3000 286ausiliario 77 1000 95dual 71A-95B 4000 381l/h
Gas liquido G30/G31 28-30/37rapido 87 3000 218ausiliario 50 1000 73dual 46A-65B 4000 291g/h
Gas naturale G25 25rapido 132 3000 332ausiliario 80 1000 111dual 71A-100B 4000 443l/h
G20 10rapido 155 3000 286ausiliario 92 1000 95dual 80A-143B 4000 381l/h

Fulgor Milano CPH 402 G X - Allacciamento metallico rigido/semirigido - 6

SERVIZIO ASSISTENZA TECNICA: 199.151.195

Dear customer,

We thank you and congratulate you on your choice.

This new carefully designed product, manufactured with the highest quality materials, has been carefully tested to satisfy all your cooking demands.

We would therefore request you to read and follow these easy instructions which will allow you to obtain excellent results right from the start.

May we wish you all the very best with your modern appliance!

THE MANUFACTURER

Index

Instructions for use

Installation

Use

Maintenance

Instructions for the installater

Installation

Gas connection

Electrical connection

User characteristics

THIS APPLIANCE IS CONCEIVED FOR DOMESTIC USE ONLY.

THE MANUFACTURER SHALL NOT IN ANY WAY BE HELD RESPONSIBLE FOR WHATEVER INJURIES OR DAMAGES ARE CAUSED BY INCORRECT INSTALLATION OR BY UNSUITABLE, WRONG OR ABSURD USE. THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS

Fulgor Milano CPH 402 G X - Instructions for the installater - 1

Italiano

Fulgor Milano CPH 402 G X - Instructions for the installater - 2

English

Fulgor Milano CPH 402 G X - Instructions for the installater - 3

Français

Fulgor Milano CPH 402 G X - Instructions for the installater - 4

Deutsch

Fulgor Milano CPH 402 G X - Instructions for the installater - 5

Español

Fulgor Milano CPH 402 G X - Instructions for the installater - 6

Português

THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY.

CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE.

Instructions for use

Installation

All the operations concerned with the installation (electrical and gas connections, adaptation to type of gas, necessary adjustments, etc.) must be carried out by qualified technicians, in terms with the standards in force. For specific instructions, kindly read the part reserved for the installation technician.

Use

Gas burners

The ignition of the gas burner is carried out by putting a small flame to the upper part holes of the burner, pressing and rotating the corresponding knob in an anti-clockwise manner, until the maximum position has coincided with the marker. When the gas burner has been turned on, adjust the flame according to need. The minimum position is found at the end of the anticlockwise rotation direction. In models with automatic ignition, operate the knob as described above, pressing simultaneously, the corresponding push-button. For models with automatic/ simultaneous (with one hand) ignition, it is sufficient to proceed as described above using the corresponding knob. The electric spark between the ignition plug and the burner provides the ignition of the burner itself. After ignition, immediately release the push-button and adjust the flame according to need. For models with a thermoelectric safety system, the burner is ignited as in the various cases described above, keeping the knob fully pressed on the maximum position for approximately 3/5 seconds. After releasing the knob, make sure the burner is actually lit.

Models with Dual Wok burner

Some models have a Dual Wok burner. The centre flame (F1) can be lit by pressing the knob and turning it clockwise or the entire burner (F2) can be lit as shown in the figure below.

F1 F2 F1

N.B

- We recommend the use of pots and pans with a diameter matching that of the burner, thus preventing the flame from escaping from the bottom part and surrounding the pot (Fig. 1);

- do not leave any empty pots or pans on the fire; When cooking is finished, it is also a good norm to close the main gas pipe tap and/or cylinder.

GAS dual Ø 20-32 fast Ø 20-24 auxiliary* Ø 10-14 Fig. 1

Important

- Use of the appliance produces heat and moisture in the room where it is installed. Make sure the kitchen is sufficiently ventilated; keep natural ventilation holes open or install mechanical ventilation devices (such as a hood).

- Prolonged use of the appliance may require additional ventilation, such as opening a window.

- On floors with thermoelectric protection do not keep the ignite button pushed for more than 15 seconds. If the burner has not ignited after 15 seconds, open the door of the room and wait at least one minute before making a further attempt.

- On floors without protection, should the burner flame go out close the corresponding gas cock and wait at least one minute before making any attempt to ignite it.

Maintenance

Prior to any operation, disconnect the appliance from the electrical system. For long-life to the equipment, a general cleaning operation must take place periodically, bearing in mind the following:

  • the glass and steel parts must be cleaned with suitable non-abrasive or corrosive products (found on the market). Avoid chlorine-base products (bleach, etc.);
  • avoid leaving acid or alkaline substances on the working area (vinegar, salt, lemonjuice, etc.);
  • the wall baffle and the small covers (mobile parts of the burner) must be washed frequently with boiling water and detergent, taking care to remove every possible encrustation. Dry carefully and check that none of the burner holes is fully or partially clogged;

Note:

If the taps need to be lubricated, it must be performed by a qualified technician, who should be contacted in the case of any operating problems.

heck periodically the state of conservation of the flexible gas feed pipe. In case of leakage, call immediately the qualified technicians for its replacement.

DO NOT USE STEAM CLEANERS

Instructions for the installer

Installation

This appliance is not provided with a combustion product discharge. It is recommended that it be installed insufficiently aerated places, in terms of the laws in force. The quantity of air which is necessary for combustion must not be below 2.0 m³/h for each kW of installed power. See table of burner power.

Note:

The appliance is in installation class 3.

The appliance's adjustment parameters are shown on the plate attached to its housing.

Positioning (Fig. 2)

The cook top is designed to be built in to a work surface as shown in the figure.

Before installing the cook top, install the gasket seal around the entire perimeter of the hole where it will be inserted.

The dimensions of the hole are shown in figures 6-7-8-9. For Filotop models, the perimeter of the hole must be lowered by a depth of 1.5 mm.

The hole does not need to be milled for Semifilotop models.

The cook top can be installed on different materials such as brickwork, steel, marble, conglomerates, synthetics, wood and wood covered with plastic laminates, so long as resistant to a temperature of 90 °C.

SEAL 40 1.5 1.5 SEAL 30 Fig. 2

600 55 MIN. 15 MIN. 650 150 MIN. 150 MIN. mm

A panel made of wood or other insulating material must be installed under the cook top at a distance of at least 15 mm from the surface.

Fig. 2

Mod: CPH 402 G
73 1

Note: Semifilotop models do not need to be lowered by 1.5 mm.

R 11 380 510 2 1

1 - AUXILIARY
2 - RAPID

R 2 381 +1 0 511 +1 0 490 +1 0 360 +1 0

1.5

Mod: CPH 401 GDWK
73 1

Note: Semifilotop models do not need to be lowered by 1.5 mm.

R 11 380 510 1

1 - DUAL

R 2 381 +1 0 511 +1 0 490 +1 0 360 +1 0

1.5

Gas connection (Fig. 3)

The connection to a gas tank or gas line must be made by a qualified person in conformity to current updated UNI-CIG 7129 and 7131 standards after making sure that the cook top is prepared for the type of gas available. If not, see: "Adapting to different types of gas". Also check that the feed pressure falls within the values shown in the table: "User characteristics".

Fig. 3
Fulgor Milano CPH 402 G X - Gas connection (Fig. 3) - 1

natural_image Simple geometric diagram showing a circle inscribed in a square frame (no text or symbols)

Metal rigid/semi-rigid hook-ups

Make the hook-up with metal fittings and pipes (even flexible hoses) so as not to stress the components inside the cook top.

Note: - After installation, use soapy water to check the perfect seal of the entire connection system.

Important note: make the connection using only metal fittings and pipes (flexible, continuous-wall steel hoses or rigid copper or steel tubing) and in such a way that its entire length can be inspected.

Electrical connection (Fig. 4)

The installer must be qualified and is responsible for correct electrical connections and following safety standards.

Prior to carrying out the electrical connection, please ensure that:

  • the plant characteristics are such as to follow what is indicated on the matrix plate placed at the bottom of the working area;
  • that the plant is fitted with an efficient earth connection, following the standards and law provisions in force. The earth connection is compulsory in terms of the law.

Should there be no cable and/or plug on the equipment, use suitable absorption material for the working temperature as well, as indicated on the matrix plate. Under no circumstance must the cable reach a temperature above 50^ C of the ambient temperature.

If connecting directly to the mains power supply, fit a multi-pole switch of a suitable size for the rated capacity

with a clearance distance which completely disconnects the power line under overvoltage category III conditions, consistently with the rules of installation (the yellow/green earth wir must not be interrupted). The plug or omnipolar switch must be easily reached on the installed equipment.

-1 2 L N

Fig. 4

If the power cord is damaged, it must be replaced by the manufacturer, its service department or a person with similar qualifications, so as to prevent any risk.

Adaptation to varius types of gas (Fig. 5)

Should the appliance be pre-set for a different type of gas than available, procreed as follows:

  • replace the injector (Fig. 5) with the corresponding type of gas to be used (see table "User characteristics");
  • to adjust to the minimum, use a screwdriver on the screw placed on the tap (Fig. 6) after turning the tap to its minimum position. For LPG (butane/propane) screw tight.

Mod. Dual
A B

Mod. 2G

Fulgor Milano CPH 402 G X - Adaptation to varius types of gas (Fig. 5) - 2

natural_image Line drawing of a hand using a tool to press or install a component on a workbench (no text or symbols)

Fig. 5

Fulgor Milano CPH 402 G X - Adaptation to varius types of gas (Fig. 5) - 3

natural_image 3D mechanical component diagram showing a washer and housing assembly (no text or symbols)

Fulgor Milano CPH 402 G X - Adaptation to varius types of gas (Fig. 5) - 4

natural_image 3D rendering of a mechanical lever assembly with a black handle and black head (no text or symbols visible)

Fulgor Milano CPH 402 G X - Adaptation to varius types of gas (Fig. 5) - 5

natural_image Technical line drawing of a mechanical component with a screw and base (no text or symbols)

Fulgor Milano CPH 402 G X - Adaptation to varius types of gas (Fig. 5) - 6

natural_image Simple line drawing of a mechanical component with a washer and housing (no text or symbols)

Fulgor Milano CPH 402 G X - Adaptation to varius types of gas (Fig. 5) - 7

natural_image Mechanical lever assembly diagram showing pivot and pivot components (no text or labels)

Fig. 6

USER CHARACTERISTICS
GAS BURNERS
FEEDTYPE PRESSURE mbarNORM.BURNER∅ INJECTORS1/100THERMALCAPACITYCONSUMPTION
Natural gas G20 20fast 129 3000 286auxiliary 77 1000 95dual 71A-95B 4000 381l/h
Liquefied gas G30/G31 28-30/37fast 87 3000 218auxiliary 50 1000 73dual 46A-65B 4000 291g/h
Natural gas G25 25fast 132 3000 332auxiliary 80 1000 111dual 71A-100B 4000 443l/h
G20 10fast 155 3000 286auxiliary 92 1000 95dual 80A-143B 4000 381l/h

Chère cliente,

natural_image Pure geometric line drawing of intersecting lines and shapes without any text or symbols

dual ∅ 20-32
rapide ∅ 20-24
auxiliaire* ∅ 10-14

Fulgor Milano CPH 402 G X - Chère cliente, - 1
Fig. 1

Important

natural_image Simple geometric diagram showing a circle inscribed in a square frame (no text or symbols)
natural_image Line drawing of a hand using a tool to press or install a component on a tray (no text or symbols)

Fig. 5

Fulgor Milano CPH 402 G X - Important - 1

natural_image 3D mechanical component diagram showing a washer and housing assembly (no text or symbols)

Fulgor Milano CPH 402 G X - Important - 2

natural_image 3D rendering of a mechanical lever assembly with a black handle and housing (no text or symbols visible)

Fulgor Milano CPH 402 G X - Important - 3

natural_image Technical line drawing of a mechanical component with a screwdriver inserted (no text or symbols)

Fulgor Milano CPH 402 G X - Important - 4

natural_image Pure technical line drawing of a mechanical component without any text, numbers, or symbols

Fulgor Milano CPH 402 G X - Important - 5

natural_image Technical line drawing of a mechanical lever assembly (no text or symbols)

Fig. 6

Fulgor Milano CPH 402 G X - Important - 6

CARACTERISTIQUES UTILISATEURS
BRULEURES A GAZ
ALIMETATIONTYPE GASTOEVER mbarNORM.BRULEUR∅ INJECTEURS1/100DEBIT THERMIQUE NOMINALWCONSOMMATION
Gaz naturel G20 20rapide 129 3000 286auxiliaires 77 1000 95dual 71A-95B 4000 381 1h
Gaz liquéfié G30/G31 28-30/37rapide 87 3000 218auxiliaires 50 1000 73dual 46A-65B 4000 291 g/h
Gaz naturel G25 25rapide 132 3000 332auxiliaires 80 1000 111dual 71A-100B 4000 443 1h
G20 10rapide 155 3000 286auxiliaires 92 1000 95dual 80A-143B 4000 381 1h
natural_image Pure technical line drawing of a mechanical component with cross-sectional views (no text or symbols)

dual ∅ 20-32
schnell ∅ 20-24
hilfbrenner* ∅ 10-14

Abb. 1

Wichting

natural_image Simple geometric diagram showing a circle inside a square with label Abb. 3 (no text or symbols within the shapes)
natural_image Line drawing of a hand using a tool to press or install a component on a flat surface (no text or symbols)

Abb. 5

Fulgor Milano CPH 402 G X - Wichting - 1

natural_image 3D mechanical component diagram showing a washer and housing assembly (no text or symbols)

Fulgor Milano CPH 402 G X - Wichting - 2

natural_image 3D rendering of a mechanical lever assembly with a black head and black shaft (no text or symbols visible)

Fulgor Milano CPH 402 G X - Wichting - 3

natural_image Technical line drawing of a mechanical component with a screwdriver inserted (no text or symbols)

Fulgor Milano CPH 402 G X - Wichting - 4

natural_image Simple line drawing of a mechanical component with a washer and housing (no text or symbols)

Fulgor Milano CPH 402 G X - Wichting - 5

natural_image Mechanical lever mechanism diagram with pivot and pivot point (no text or symbols)

Abb. 6

Fulgor Milano CPH 402 G X - Wichting - 6

TECHNISCHE DATEN
GASBRENNSTELLEN
SPEISUNG TYP DRUCK mbar NORMALBRENNERTYP∅ DÜSENELEMENTE 1/100WÄRMEBELASTUNG NOMINAL WVERBRAUCH
Naturgas G20 20schnell 129 3000 286hilfsbrenner 77 1000 95dual 71A-95B 4000 381l/h
Naturgas G30/G31 28-30/37schnell 87 3000 218hilfsbrenner 50 1000 73dual 46A-65B 4000 291g/h
Naturgas G25 25schnell 132 3000 332hilfsbrenner 80 1000 111dual 71A-100B 4000 443l/h
G20 10schnell 155 3000 286hilfsbrenner 92 1000 95dual 80A-143B 4000 381l/h

Estimado Cliente,

natural_image Pure technical line drawing of two mechanical components without any text or symbols

dual ∅ 20-32
rápido ∅ 20-24
auxiliar ∅ 10-14

Fig. 1

Importante

natural_image Simple geometric diagram showing a circle inside a square, labeled 'Fig. 3' (no text or symbols within the diagram itself)
natural_image Line drawing of a hand using a tool to press or install a component on a flat surface (no text or symbols)

Fig. 5

Fulgor Milano CPH 402 G X - Importante - 1

natural_image 3D mechanical component diagram showing a washer and housing assembly (no text or symbols)

Fulgor Milano CPH 402 G X - Importante - 2

natural_image 3D rendering of a mechanical lever assembly with a black handle and housing (no text or symbols visible)

Fulgor Milano CPH 402 G X - Importante - 3

natural_image Technical line drawing of a mechanical component with a screw and base (no text or symbols)

Fulgor Milano CPH 402 G X - Importante - 4

natural_image Pure technical line drawing of a mechanical component without any text, numbers, or symbols

Fulgor Milano CPH 402 G X - Importante - 5

natural_image Mechanical lever assembly diagram showing pivot and pivot components (no text or labels)

Fig. 6

CARACTERISTICAS UTILIZADORES
QUEMADORES DE GAS
ALIMENTACION TIPO PRESION mbar NORM.QUEMADOR∅ INYECTORES 1/100CAPACIDAD TÉRMICACONSUMPTION
Gas natural G20 20rápido 129 3000 286auxiliar 77 1000 95dual 71A-95B 4000 381l/h
Gas licuefacto G30/G31 28-30/37rápido 87 3000 218auxiliar 50 1000 73dual 46A-65B 4000 291g/h
Gas natural G25 25rápido 132 3000 332auxiliar 80 1000 111dual 71A-100B 4000 443l/h
G20 10rápido 155 3000 286auxiliar 92 1000 95dual 80A-143B 4000 381l/h

Ex.mo. Sr. Cliente,

natural_image Simple geometric diagram showing a circle inside a square, labeled 'Fig. 3' (no text or symbols within the diagram itself)
natural_image Line drawing of a hand using a tool to press or install a component on a flat surface (no text or symbols)

Fig. 5

Fulgor Milano CPH 402 G X - Ex.mo. Sr. Cliente, - 1

natural_image 3D mechanical component diagram showing a washer and housing assembly (no text or symbols)

Fulgor Milano CPH 402 G X - Ex.mo. Sr. Cliente, - 2

natural_image 3D rendering of a mechanical lever assembly with a black head and black shaft (no text or symbols visible)

Fulgor Milano CPH 402 G X - Ex.mo. Sr. Cliente, - 3

natural_image Technical line drawing of a mechanical component with a screw and base (no text or symbols)

Fulgor Milano CPH 402 G X - Ex.mo. Sr. Cliente, - 4

natural_image Simple line drawing of a mechanical component with a washer and housing (no text or symbols)

Fulgor Milano CPH 402 G X - Ex.mo. Sr. Cliente, - 5

natural_image Mechanical lever mechanism diagram showing pivot point and pivot shaft (no text or labels)

Fig. 6

CARACTERÍSTICAS DAS PEÇAS A UTILIZAR
QUEIMADORES DE GAS
ALIMENTAÇÃO TIPO PRESSÃO mbar NORM.QUEIMADOR∅ BICOS 1/100CAPACIDADE TÉRMICACONSUMO
Gás natural G20 20ràpido 129 3000 286auxiliar 77 1000 95dual 71A-95B 4000 381l/h
Gás licuefeito G30/G31 28-30/37ràpido 87 3000 218auxiliar 50 1000 73dual 46A-65B 4000 291g/h
Gás natural G25 25ràpido 132 3000 332auxiliar 80 1000 111dual 71A-100B 4000 443l/h
G20 10ràpido 155 3000 286auxiliar 92 1000 95dual 80A-143B 4000 381l/h
Manual assistant