Zephyr ET - Air conditioner Andrews - Free user manual and instructions
Find the device manual for free Zephyr ET Andrews in PDF.
| Product Type | Portable air conditioner |
| Model | Zephyr ET |
| Brand | Andrews |
| Power Supply | 230 V, 13 A, 50 Hz single phase |
| Cooling Type | Air cooled with exhaust duct |
| Control Panel | Thermostat knob, mode switch, fan speed switch |
| Fan Speeds | High and low |
| Air Flow Adjustment | Adjustable vertical and horizontal louvres |
| Condensate Management | Internal tank (user-emptied) or optional pump |
| Filter Type | Washable foam filter (front and rear) |
| Filter Cleaning | Wash in warm soapy water, rinse, shake dry |
| Filter Cleaning Interval | At least every 2 months |
| Filter Replacement | Approximately every 12 months |
| Safety Features | RCD recommended, automatic shut-off via thermostat |
| Electrical Protection | 13 A fuse required |
| Extension Cable Requirement | 2.5 mm² minimum for up to 10 m; 4 mm² for longer runs |
| Mounting | Free-standing floor unit |
| Exhaust Ducting | Fixed or flexible duct to outside |
| User Manual Included | Yes (PDF available for download) |
Frequently Asked Questions - Zephyr ET Andrews
User questions about Zephyr ET Andrews
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air conditioner in PDF format for free! Find your manual Zephyr ET - Andrews and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Zephyr ET by Andrews.
USER MANUAL Zephyr ET Andrews
Zephyr ET Portable Air Conditioning

natural_image
Two industrial air conditioning machines, one white and one blue, displayed side by side (no visible text or symbols on the devices themselves)Operating Instructions & Safety Guide

ANDREWS
AIR CONDITIONING
General Safety
- Keep children and animals away from air conditioning units. Never leave them alone in a room where the units in use.
This equipment should only be used by a competent person who has read and understood these instructions.
Never operate this equipment if you are ill, feeling tired or under the influence of alcohol or drugs. - Keep the Air Conditioning vents clear of all obstructions.
Never put anything on top of the unit or block the air outlets.
Make sure equipment is switched off and unplugged after use
Never leave switched on or unattended.
Do not use the unit where sunlight is shining directly onto it.
Check condition of equipment before use. If unit is showing signs of damage contact your supplier immediately.
Electrical Safety
This unit requires a 230 volt electrical supply. It plugs into a standard BS1363 domestic socket.
Always inspect plugs and leads for damage before plugging into the supply - DO NOT USE IF ANY DAMAGE IS FOUND
Ensure cables are run as not to cause a hazard.
If an extension lead is used, ensure it is of the correct standard, and fully uncoiled when being used.
Do not lay electrical cables in wet / damp areas.
Do not move equipment whilst operating.
Do not pull equipment by its cable.
It is recommended that electrical equipment is used via a suitable RCD.
WARNING!
As standard this unit requires a 13 amp fused electrical supply rated at 230v 1ph 50hz.
The unit will operate from a standard 13A wall socket. The size of any extension cable that may be 2-5mm2 minimum up to a maximum length of 10 metres. For longer lengths 4mm2 cable must be used. If the cable is on a 'cable drum' then ensure that it is completely unwound; serious complications will occur otherwise.
Air Cooled Units
The system comprises, a room unit fitted with either a fixed or flexible ducting system as specified by the customer. Condensate is collected, either in the units internal tank and emptied by the user or pumped using an optional condensate disposal unit (fig. 1).
Air Flow
The angled air outlets at the top of the room unit are fitted with air grilles that allow the angle of air outlet to be adjusted vertically and horizontally and, in conjunction with the fan speed control switch, the air velocity and direction can be carefully set up to obtain maximum coverage of the area being cooled without causing drafts. Care should be taken to avoid outlet air being obstructed as this will cause the air to 'eddy' around the unit resulting in recirculation and short/inaccurate cycling of the machine. Ideally, cold air should be directed to create a 'blanket' all across the ceiling area allowing natural convection to drop the air over the whole area at very low velocity. An alternative top panel with twin 7" ducts is available.
Siting of Zephyr
Ideally, the room unit should be positioned equidistant along he shortest wall in the room blowing down the length of the room. Of there is more than one unit in the same area, then they would normally be positioned side by side, and equidistant along the long wall, all pointing in the same direction. Sometimes it may be necessary to position units around the perimeter of an area but, in this case, great care should be taken t avoid one unit blowing cold air straight into another which will adversely affect the machine operation. Good and correct air flow is, perhaps, the single most important aspect of satisfactory applying portable air conditioners. If in doubt seek the advice of your supplier.
Exhaust Tubes Air Cooled Unit
The exhaust tube(s) must carry the air to an area external to that being cooled, preferably in the outside atmosphere (fig. 1).
Operating Instructions - Zephyr ET
Operation Instructions
The control panel on the room unit is illustrated below
Revolve thermostat knob fully CLOCKWISE to the number '8' position
Plug in the room unit mains cable, and switch on the electricity, red mains light will illuminate.
Select 'Fan Only' with the mode switch. The fan will start.
Select 'Fan Speed' with the fan speed switch, high or low depending on air velocity required.
Select 'Cooling' with the mode switch, and revolve the thermostat knob fully ANTI-CLOCKWISE to he number '1' position. After a delay of 10 mins the green 'Cooling' light will illuminate and the machine will proceed to cool the air.
Monitor the room temperature and when it has reduced to the desired level, very slowly revolve the thermostat knob back, clockwise until the green 'Cooling' light goes out. The room unit will now control the room temperature cooling automatically at this setting.

Routine Maintenance
The air filter must be kept clean, never allow to become choked with dust or dirt. If allowed to do so, the performance of the unit will become impaired, resulting in loss of air flow, freezing up the evaporator coil and possible component damage.
Accessing the Filter
On machines fitted with a hinged lower panel, open panel. The filter is located on front of the evaporator. A second filter is fitted to the rear panel on all air cooled machines.
On machines without a hinged front panel, to access the filter, lift out the return air grille on the front face of the unit. On refitting the filter ensure that it is correctly positioned covering the whole face of the grille.
The filter (see Fig 4) can be washed in warm, soapy water, rinsed and shaken dry before replacement. Frequency of cleaning depends upon
application and can only be determined by the user. However, you should never allow more than two months to elapse between cleaning. The probable life of the filter will be about one year and spares are available from the supplier of the unit itself. Failure to have filter fitted during operation will cause serious damage (see fig. 4 / 5).
| Problem Likely Cause Solution | ||
| No cooling Amber 'ATTENTION' light illuminated. High level condensate trip. | Condensate pump not reducing water level Kink in condensate tube between room unit and external heat exchanger? Leak inside room unit. Pump filter inside room unit blocked. Condensate tube frozen. | |
| No cooling Amber 'ATTENTION' light illuminated. Bottle fitted switch trip. | On machines without a removable bottle, ensure link fitted to terminal block. On machines with , ensure bottle fitted correctly. | |
| No cooling Amber 'CONTAINER FULL' light illuminated. High level condensate trip. | On machines without a removable bottle, as above. On machines with a bottle, remove container and replace correctly. To empty the condensate bottle, pull forward the lower front panel, (Fig 2).The front cover will come forward, giving access to the container, (Fig 3).Empty the container, and carefully replace.Ensure the drain pipe is fitted into the container. | |

natural_image
Two-panel photo showing a white flexible hose fitting a hot air exhaust device, both in blue-tinted lighting (no text or symbols visible)
natural_image
Close-up of hands holding a white object, possibly a mechanical part or tool, in blue-tinted lighting (no visible text or symbols)
natural_image
Close-up of a hand holding a laptop near a window, no visible text or symbols
natural_image
Interior view of a laboratory or lab equipment unit with a white plastic container and blue tubing (no visible text or symbols)
natural_image
Person installing or adjusting a blue panel on a wall (no visible text or symbols)
natural_image
Close-up of a small transparent container with grid pattern, being handled by gloved hands (no visible text or symbols)The filter is located on the rear of the unit, ensure it is kept clean.