Product Type Digital Thermometer
Brand Medel
Model ECOtemp
Measurement Range 32.0°C – 42.0°C (89.6°F – 107.6°F)
Accuracy ±0.1°C (±0.2°F) within 35.5°C – 42.0°C
Measurement Time Approximately 30 seconds
Display Type LCD with backlight
Battery Type 1 x CR2032 (included)
Battery Life Approximately 100 hours of continuous use
Auto-Off Yes, after approximately 10 minutes of inactivity
Dimensions (L x W x H) 140 mm x 25 mm x 15 mm
Weight Approximately 20 g (including battery)
Material ABS plastic, stainless steel probe
Water Resistance Water-resistant (IP54)
Measurement Method Predictive (peak) measurement
Memory Function Stores last measured temperature
Fever Alert Yes, audible beep and red backlight
Measurement Unit Switchable °C / °F
Cleaning and Disinfection Wipe with soft cloth dampened with isopropyl alcohol
Storage Temperature -10°C – 50°C (14°F – 122°F)
Operating Temperature 10°C – 40°C (50°F – 104°F)
Safety Standards CE, FDA, ISO 80601-2-56
Warranty 2 years
Replaceable Parts Battery (CR2032)

Frequently Asked Questions - ECOtemp Medel

How do I switch between Celsius and Fahrenheit?
With the device off, press and hold the power button for 5 seconds. The display will show the current unit; press the button again to toggle. The unit will automatically save your selection.
How long does it take to get a reading?
The ECOtemp provides a reading in approximately 30 seconds. However, for best accuracy, keep the probe under the tongue or in the armpit until the beep sounds.
What type of battery does it use and how do I replace it?
It uses one CR2032 battery. To replace, gently slide the battery cover off, remove the old battery, insert a new one with the positive side up, and close the cover.
How do I clean the thermometer?
Clean the probe after each use with a soft cloth dampened with isopropyl alcohol (70%). Do not submerge in water or use abrasive cleaners.
What does the fever alert mean?
A fever alert is indicated by a red backlight and a series of beeps when the temperature exceeds 37.5°C (99.5°F). It signals a potential fever.
Can I use the thermometer on children?
Yes, the thermometer is safe for children. For infants, it is recommended to use the rectal measurement method for the most accurate reading.
What is the measurement accuracy?
The accuracy is ±0.1°C (±0.2°F) in the range of 35.5°C – 42.0°C. Outside this range, accuracy may be slightly lower.
Why does the display show 'Lo' or 'Hi'?
'Lo' indicates the temperature is below 32.0°C (89.6°F). 'Hi' indicates it is above 42.0°C (107.6°F). Ensure proper placement and wait for the device to stabilize.
How do I store the thermometer when not in use?
Store it in a cool, dry place within the temperature range -10°C to 50°C (14°F to 122°F). Avoid direct sunlight and extreme humidity.
Is the thermometer waterproof?
The thermometer is water-resistant (IP54), meaning it can withstand splashes but should not be immersed in water. Clean with a damp cloth only.

User questions about ECOtemp Medel

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermometer in PDF format for free! Find your manual ECOtemp - Medel and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ECOtemp by Medel.

USER MANUAL ECOtemp Medel

a. Mercury free clinic. Thermometer is a kind of measuring device for patient's temperature, and it can be used to measure the temperature of patient's mouth or amplit or anus.

b: The product is a compliance with EN 2475-1:8354A:2009. Clinical thermometers - Part 1: Metallic liquid-in glass thermometers with maximum device

The conditions of use, measuring temperature range should be between 35°C to 42°C, and the environment temperature should be 20°C to 30°C. If the temperature for storage is less than 20°C, please put the thermometers in the temperature 20°C to 30°C for at least 1-2 hours or 30°C to 35°C for ten minutes before use or test.

  1. The temperature must be less than 42°C when it is stored and transported;

  2. Disposal of the thermometer after use, swing the metallic liquid down then clearing it and cut it plastic case to avoid any damage.

Notice for swing: catch the tall part of the thermometer by thumb and forefinger tightly and carefully, swing the thermometer lightly several times until the liquid down.

The liquid column shall fall below the lowest numbered scale mark before use, then clean and disinfect the clinical thermometer in medical alcohol or pul on a disinfected prasic tube

  1. Be careful to put it below the tongue of patients for oral clinical thermometer and tell them to close their mouth slightly.

  2. A clinical thermometer for rectal use is applied some lubricator before used no 1 in the anus

  3. Be careful to put it below the ampit of patients for ampit clinical hemometer and tell them to light it, jointly

Warning

- Warm patient against chewing, speaking and clamping when the clinical hemometers are below the torque of patients

  1. Need to let sick children lie quietly and help them to find another end of the clinical thermometer for rectal use in case it is inserted too deep, or it slows from the anus.

  2. Avoid having a bath, eating or smoking half an hour before taking body temperature.

  3. It is not designed for special applications (e.g. thermometers for premature babies, ovulation thermometers).

WARRANTY / SERVICE

- The device is guaranteed for 2 years from the date of purchase against any defects originating in materials or warranty.

- The warranty consists of free replacement of defective components at the origin.

- The warranty does not cover accessories supplied and parts subject to normal wear and tear.

• The shipping costs of the appliance are borne by the user.

- The warranty's shall issue if the appliance has been tampered with, if the defect is caused by improper use or if the damage is not attributable to the manufacturer (accidental fall, improper transport, etc.).

- The warranty does not imply any compensation for damages, either direct or indirect, of any kind, to people or properly during the period in which the product cannot be used.

- The warranty is valid from the date of purchase of the product certified by the receipt, or the purchase invoice.

DISPOSAL OF THE CLINICAL THERMOMETERS

The metallic liquid is an alloy consisting of gallium, indium and tin, this clinical thermometer should be handled with care. In particular, car should be taken to avoid dropping the instrument or treating it in any way that could result in damage when the clinical thermometers are broken, cleaning split metallic liquid by a damp cloth with soap pads.

TECHNICAL SPECIFICATIONS Model ECOTEMP

Measuring factor 35° - 42° Type CFW03

Respulor: 0119

Accuracy -0.1°C / -0.15°C

PL

Precise: +0.1℃ / -0.15℃

Vedel:ECOIEMP

Tie: CR/400

EL

Akoßem: +0.1°C / -0.5°C

15.54.00-FCCTMP

Всёрує: СР7400

AR

No.43 Xixin Road, Zhangjing, Xibei Town, Wuxi City,

Jiangsu, 214194 China

EC REP Lotus NL B. V.

Koningin Julianaplein 10, le Verd, 2595AA, The Hague, Netherlands.

Tel: 0031626669008, Email: peter@lotusnl.com

Distributed by:

Medel International Srl

Via Villapizzone 26 - 20156 Milano / Italy

www.medelinternational.it

Medel ECOtemp - AR - 1

1023

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Medel

Model : ECOtemp

Category : Thermometer