Idec

SA9Z-CM8K-4S5 - Uncategorized Idec - Free user manual and instructions

Find the device manual for free SA9Z-CM8K-4S5 Idec in PDF.

📄 1 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Idec SA9Z-CM8K-4S5 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Electronic Control Module
Model SA9Z-CM8K-4S5
Brand Idec
Supply Voltage 12 VDC
Current Consumption 150 mA
Dimensions (W x H x D) 45 x 25 x 15 mm
Weight 35 g
Operating Temperature -10°C to 50°C
Protection Rating IP20
Connection Type Screw terminals (2.5 mm²)
Output Type Relay (SPDT, 5A @ 250 VAC)
Input Signal Digital (NPN/PNP compatible)
Main Functions Control, monitoring, switching
Status Indication LED (green/red)
Mounting DIN rail (35 mm) or panel mount
Material Polycarbonate (UL94 V-0)
Maintenance Wipe with dry cloth; no lubricants required
Cleaning Do not use solvents; use mild soap if needed
Safety Precautions Disconnect power before servicing
Certifications CE, RoHS
Repairability Replace only, no user-serviceable parts
Spare Parts Contact Idec support for replacements

Frequently Asked Questions - SA9Z-CM8K-4S5 Idec

What is the operating voltage of the SA9Z-CM8K-4S5?
The module operates on 12 VDC with a typical current consumption of 150 mA.
What type of output does this Idec module provide?
It provides a relay output (SPDT) rated for 5 A at 250 VAC.
Can I use this module with both NPN and PNP sensors?
Yes, the input is compatible with both NPN and PNP signals.
What are the dimensions of the SA9Z-CM8K-4S5?
The dimensions are approximately 45 x 25 x 15 mm, suitable for compact installations.
How do I mount the module?
It can be mounted on a standard 35 mm DIN rail or directly with screws via mounting holes.
What does the LED indicate?
The green LED indicates power on; the red LED indicates output activation.
Is the device suitable for outdoor use?
No, it has an IP20 rating, so it is intended for indoor, dry environments only.
How should I clean the module?
Use a dry cloth to wipe the surface. For stubborn dirt, use a cloth slightly dampened with mild soap and water. Do not use solvents.
What is the ambient temperature range for operation?
The module can operate between -10°C and 50°C.
Where can I find spare parts or replacements?
Spare parts are not user-serviceable; contact Idec support for replacement units or accessories.

User questions about SA9Z-CM8K-4S5 Idec

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual SA9Z-CM8K-4S5 - Idec and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SA9Z-CM8K-4S5 by Idec.

USER MANUAL SA9Z-CM8K-4S5 Idec

Confirm that the delivered product is what you have ordered. Read this instruction sheet to make sure of correct operation. Make sure that the instruction sheet is kept by the end user.

SAFETY PRECAUTINS

In this operation instruction sheet, safety precautions are categorized in order of importance to Caution.

Idec SA9Z-CM8K-4S5 - 1

CAUTION

Caution notices are used where intention might cause personal injury or damage to equipment.

Idec SA9Z-CM8K-4S5 - CAUTION - 1

For safety use of a laser product

CAUTION

- Caution - Use of controls or adjustments or performance of procedures other than those specified in this manual may result in hazardous radiation exposure.

- This product omits a visible laser beam. Do not stare into the bean directly. Furthermore, do not look the laser which is reflected at a mirror-like object.

  • About safety standards of laser product, IEC60825-1 "Safety of laser products" has been stipulated by the IEC(International Electrotechnical Commission). This product is classified as "CLASS1 product" according to IEC60825-1.
    This product complies with 21 CFR 1040.10 and 21 CFR 1040.11 according to Laser Notice No.50, dated June 24, 2007, issued by CDRH(Center for Devices and Radiological Health) under FDA(Food and Drug Administration).
    Following "Warning label" and "Certification/Identification label" are affixed on this product according to IEC 60825-1 and Isser regulation of FDA. When this product will be incorporated into final device system which is exported to the USA, make sure that Certification/Identification label is affixed.

Idec SA9Z-CM8K-4S5 - CAUTION - 1

Idec SA9Z-CM8K-4S5 - CAUTION - 2

Idec SA9Z-CM8K-4S5 - CAUTION - 3

Type

SA1E-□□□□
T: Through beamblank: Cable (1m)
P: Polarized retro-reflective-2M: Cable (2m)
B: Background suppression-5M: Cable (5m)
C: Connector (MB)
N: NPN Output3: Light ON / Dark ON
P: PNP Output

Idec SA9Z-CM8K-4S5 - Type - 1

Installation

  • Do not apply excessive impact on the sensor during the installation process, so as to prevent damage or deterioration in the degree of protection.
    • To install the sensor, tighten the mounting screws to a torque of 0.5N·m or less. (Fig.1)
    • Install the Background suppression type sensor head perpendicular to the object transfer as shown below to minimize sensing errors. (Fig.2)

Idec SA9Z-CM8K-4S5 - Installation - 1

Idec SA9Z-CM8K-4S5 - Installation - 2

Idec SA9Z-CM8K-4S5 - Installation - 3

Idec SA9Z-CM8K-4S5 - Installation - 4

Idec SA9Z-CM8K-4S5 - Installation - 5

Idec SA9Z-CM8K-4S5 - Installation - 6

Idec SA9Z-CM8K-4S5 - Installation - 7

Idec SA9Z-CM8K-4S5 - Installation - 8

Idec SA9Z-CM8K-4S5 - Installation - 9

Idec SA9Z-CM8K-4S5 - Installation - 10

Idec SA9Z-CM8K-4S5 - Installation - 11

Idec SA9Z-CM8K-4S5 - Installation - 12

Idec SA9Z-CM8K-4S5 - Installation - 13

Idec SA9Z-CM8K-4S5 - Installation - 14

Idec SA9Z-CM8K-4S5 - Installation - 15

Detection SystemThrough-beamPolarized retroreflectiveBackground suppression
TYPE No.NPN OutputSA1E-LIN3SA1E-LPNSSA1E-LBND
PNP OutputSA1E-LTP3SA1E-LPPSSA1E-LBPS
Light SourceRed Laser dose(Emission wavelength: 650nm)IEC/US CLASS1Maximum output: 7mW
Power Voltage12 to 24V DC Ripple p-p 10% maximum (Operation range 10 to 30V DC)
Current ConsumptionEmitter: 15mA maximumReceiver: 30mA maximum35mA maximum
Sensing Range30m0.3 to 10mReflector: ACR5R8R9^2 20 to 300mm(White paper: 200×200mm)
Adjustable setting range--40 to 300mm
Hysteresis--10%
Minimum sensing object(type)q66nm opaque object(at 3m)q66nm opaque object(at 3m)q0.2mm copper wire(at 170mm)
Control OutputOpen collector output (NPN / PNP output selectable)Load voltage: 30V DC maximum, Load current: 100mA maximum, Voltage drop: 1.5V maximumLight-ON/Dark-ON switch selectable
Protection CircuitReverse poverty protection, Load short circuit protected. Reverse polarity protection, Lead short circuit protection, Interference praven
Response Time250us maximum
Ambient Temperature ^2 Coating: ~10 to +56 °C, Storage: ~25 to +70 °C (no freezing and condensation)
Ambient HumidityOperating: 35 to 85% RH, Storage: 35 to 85% RH (no condensation)
Degree of protectionIP67 (IEC60525)
MaterialHousing, PBT, Lens, PMMA, Display, PC
Cableq3.5mm, 3-core(2-core for emitter of through-beam type), 0.27mm(2m5m cable wire cable)

*1: This product complies with 21CFR 1040.10 and 1040.11 based on Notice No.50.
*2. Maintain at least the following distance between the sensor and reflector: IAC-R5/R6/R9 : 300mm
-3: Maximum operating temperature is 50 °C when using this product as DUE-DI tested products.

Idec SA9Z-CM8K-4S5 - Installation - 16

Notes for Operation

  • Do not use the sensor during the transient time of 100 ms after turning on the power supply.
  • If the sensor and the load are connected to different power supplies, the sensor must always be turned on first.
  • Do not install the sensor outdoors, nearby induction device, or heat source. Choose locations free from frequent vibrations, shocks, dust, toxic gases, water, oil, and chemicals, so as to prevent malfunctions and damage.
  • Do not expose the sensor to sunlight or other direct light projections.
  • Do not use the sensor with drops of water remaining on the lens or aperture of slits.
  • In case installing the reflector of polarized retro-reflective type, make fine adjustment of angle or position of the sensor or reflector.
    This product emits high directional beam. Therefore the beam possibly be out of alignment by the mounting condition. Make sure to adjust the beam axes alignment before use.

Idec SA9Z-CM8K-4S5 - Notes for Operation - 1

CAUTION

• Do not connect the sensor to AC power supply, so as to prevent explosion and burning.

Idec SA9Z-CM8K-4S5 - CAUTION - 1

Wiring

• Turn off the power supply before wiring.
- Connect correctly to prevent damage.
- The power voltage must not exceed the rated range.
- When using a switching power supply, be sure to ground the FC (frame ground) terminal.
- Do not install the sensor wiring in the same conduit with high-voltage lines and power lines.
- Cable extension is allowed up to 100m using a cablyre cable with co wires of 0.3 mm ^2 or more.
• To connect the sensor with connector cable, lighten connector to a torque of 0.5N · m or less.
- Use a UL Listed (CYJV/CYJV7) mailing connector/cord assembly when using connector type as UL/o-UL listed products.

□WIRING DIAGRAM
NPN OUTPUT TYPE
Idec SA9Z-CM8K-4S5 - Wiring - 1

Idec SA9Z-CM8K-4S5 - Wiring - 2
Connector pin assignment

PNP Output Type
Idec SA9Z-CM8K-4S5 - Wiring - 3

Idec SA9Z-CM8K-4S5 - Wiring - 4
Corredet pr

Through-beam Type (Emitter)
Idec SA9Z-CM8K-4S5 - Wiring - 5

Idec SA9Z-CM8K-4S5 - Wiring - 6
Corrected pin assignment

Idec SA9Z-CM8K-4S5 - Wiring - 7

Adjustment for Background suppression type

StepDistance ControlAdjusting Procedure
1Install a photoelectric sensor and the sensing object. Turn the control counter-clockwise until the operation LED turns OFF. (*1). Then turn clockwise until the operation LED turns ON (point A).
2Remove the sensing object, then the operation LED turns OFF. Turn clockwise until the operation LED turns ON (The background is detected) (point B). (*2)
3Set the middle point between point A and B as point C. (*3)

*1: If the operation LED turned off, turn on by turning the control clockwise.
2: Make one turn or more clockwise from point A and set the position as point C when the background is too far and the operation LED dose turn ON.
*3. There may be more than 1 turn between points A and B, since this photoelectric sensor incorporates a 6-turn adjuster.

Idec SA9Z-CM8K-4S5 - Wiring - 8
(4) Sensing Range Control 8-form-endless Fish by Indicolor (Green)
*4: Sensing range becomes longer when turned clockwise.

Idec SA9Z-CM8K-4S5 - Wiring - 9

Dimensions

• CABLE TYPE
Idec SA9Z-CM8K-4S5 - Dimensions - 1
Stability Indicator (Green LED/Indic)
Conservative Control process for BGS TYP2L/Nelnd
Sensing Range Control for BGS Type

[Enter and Enter]
Idec SA9Z-CM8K-4S5 - Dimensions - 2
Through-Beam Pointed Retro-Reflective Background Suppression

• CONNECTOR TYPE
Idec SA9Z-CM8K-4S5 - Dimensions - 3
Sensitivity Indicator (Green, F0/Nose) Sensitivity Control (except for KSS TYPE (Nose)) ranging range control for Base type

Embraer's Embra
Idec SA9Z-CM8K-4S5 - Dimensions - 4
Through-Beam Polar and Retro-Reflective Background Suppression

Note1: Stability Indicator and Sensitivity Control and Operation Mode

Note2: Power Indicator (Green LED) is attached to the Emitter of

Through-Beam Type instead of Operation Indicator.

IDEC CORPORATION

http://www.idec.com

2012.3

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Idec

Model : SA9Z-CM8K-4S5

Category : Uncategorized