Frequently Asked Questions - AOYG30LBTA FUJITSU
How do I clean the air filter?
To clean the air filter, turn off the unit and open the front panel. Remove the filter and wash it with lukewarm water. Let it dry completely before reinstalling. Regular cleaning every 2 weeks is recommended for optimal performance.
How do I set the timer?
Press the Timer button on the remote control. Use the +/- buttons to set the desired on/off time. Press Set to confirm. The timer indicator will appear on the display.
What do the error codes mean?
Common error codes include E1 (indoor unit PCB fault), E2 (outdoor unit fault), and E3 (sensor fault). Refer to the full error code list in the manual or contact Fujitsu support.
How do I switch between cooling and heating?
Press the Mode button on the remote control until the desired mode icon appears. Modes include Cool, Heat, Fan, Dry, and Auto.
Why is the unit not cooling properly?
Check if the filter is dirty, the thermostat is set correctly, or the outdoor unit is blocked. Ensure windows and doors are closed. If problem persists, contact a technician.
Can I install the unit myself?
Professional installation is highly recommended. The unit contains refrigerant and requires electrical work. Improper installation may void warranty and cause safety hazards.
How do I use the remote control?
Insert two AAA batteries. Point the remote at the indoor unit. Press Power to turn on/off. Use Temp, Fan, and Mode buttons to adjust settings.
What is the recommended temperature setting?
For cooling, set between 24-26°C. For heating, 20-22°C. This ensures comfort and energy efficiency.
How often should I service the unit?
Annual professional maintenance is recommended. Clean the filter every 2-4 weeks. Check outdoor unit for debris regularly.
Where can I download the user manual?
The user manual is available for free download on notice-facile.com in PDF format. Search for model AOYG30LBTA Fujitsu.
USER MANUAL AOYG30LBTA FUJITSU
Infomation sheet (Lot. 10)
This information includes the results of calculation of the seasonal energy consumption and efficiency for air conditioner in regards to ErP pursuant to the Commission Regulation(EU) No.206/2012 and No.626/2011.
Information to identify the model(s) to which the information relates to:
AIR CONDITIONER
| TYPE : | SINGLE SPLITDUCT |
| indoor unit(s) : | ARYG30LHTBP |
| outdoor unit | AOYG30LBTA |
| BRAND | FUJITSU |
N/A = Not Applicable
| Function |
| Cooling Average | Yes Yes | | |
| Heating Warmer | Yes No | | |
| Colder | No |
| Design load Seasonal efficiency | |
| Item Symbol Value Unit | Item Symbo | Value Unit | | | | |
| Cooling | Pdesignc | 8.5 5.95 | kW | Cooling | SEER | | - |
| Heating/Average | Pdesignc | 8.0 3.95 | kW | Heating/Average | SCOP/A | | - |
| Heating/Warmer | Pdesignc | N/A N/A | kW | Heating/Warmer | SCOP/W | | - |
| Heating/Colder | Pdesignc | N/A N/A | kW | Heating/Colder | SCOP/C | | - |
| Cooling |
| Declared capacity for cooling,at indoor temperature 27 (19) °C and outdoor temperature Tj | Declared energy efficiency ratio,at indoor temperature 27 (19) °C and outdoor temperature Tj |
| Item Symbol Value Unit | | | | Item Symbol Value Unit | | | |
| Tj = 35°C | Pdc | 8.50 | 3.21 kW | Tj = 35°C | EERd | | - |
| Tj = 30°C | Pdc | 6.26 | 4.86 kW | Tj = 30°C | EERd | | - |
| Tj = 25°C | Pdc | 4.35 | 7.18 kW | Tj = 25°C | EERd | | - |
| Tj = 20°C | Pdc | 4.47 | 9.13 kW | Tj = 20°C | EERd | | - |
| Heating/Average |
| Declared capacity for heating/Average season,at indoor temperature 20 °C and outdoor temperature Tj | Declared capacity for heating/Average season,at indoor temperature 20 °C and outdoor temperature Tj |
| Item Symbol Value Unit | Item Symbo | Value Unit | | | | | |
| Tj = -7°C | Pdh | 7.08 2.73 kW | Tj = -7°C | COPd | | | - |
| Tj = 2°C | Pdh | 4.31 4.04 kW | Tj = 2°C | COPd | | | - |
| Tj = 7°C | Pdh | 3.12 4.96 kW | Tj = 7°C | COPd | | | - |
| Tj = 12°C | Pdh | 3.25 5.21 kW | Tj = 12°C | COPd | | | - |
| Tj = bivalent temperature | Pdh | 7.08 2.73 kW | Tj = bivalent temperature | COPd | | | - |
| Tj = operating limit | Pdh | 6.64 2.67 kW | Tj = operating limit | COPd | | | - |
| Heating/Warmer |
| Declared capacity for heating/Warmer season,at indoor temperature 20 °C and outdoor temperature Tj | Declared capacity for heating/Warmer season,at indoor temperature 20 °C and outdoor temperature Tj |
| Item Symbol Value Unit | | | | Item Symbol Value Unit | | | |
| Tj = 2°C | Pdh | N/A N/A | kW | Tj = 2°C | COPd | | - |
| Tj = 7°C | Pdh | N/A N/A | kW | Tj = 7°C | COPd | | - |
| Tj = 12°C | Pdh | N/A N/A | kW | Tj = 12°C | COPd | | - |
| Tj = bivalent temperature | Pdh | N/A N/A | kW | Tj = bivalent temperature | COPd | | - |
| Tj = operating limit | Pdh | N/A N/A | kW | Tj = operating limit | COPd | | - |
| Heating/Colder |
| Declared capacity for heating/Colder season,at indoor temperature 20 °C and outdoor temperature Tj | Declared capacity for heating/Colder season,at indoor temperature 20 °C and outdoor temperature Tj |
| Item Symbol Value Unit | | | | Item Symbol Value Unit | | | |
| Tj = -7°C | Pdh | N/A N/A | kW | Tj = -7°C | COPd | | - |
| Tj = 2°C | Pdh | N/A N/A | kW | Tj = 2°C | COPd | | - |
| Tj = 7°C | Pdh | N/A N/A | kW | Tj = 7°C | COPd | | - |
| Tj = 12°C | Pdh | N/A | kW | Tj = 12°C | COPd | N/A | - |
| Tj = bivalent temperature | Pdh | N/A N/A | kW | Tj = bivalent temperature | COPd | | - |
| Tj = operating limit | Pdh | N/A N/A | kW | Tj = operating limit | COPd | | - |
| Tj=-15°C | Pdh | N/A N/A | kW | Tj=-15°C | COPd | | - |
| Bivalent temperature Operating limit temperature | |
| Item Symbol Value Unit | | | | Item Symbol Value Unit | | | |
| Heating/Average | Tbiv | -7 -15 | °C | Heating/Average | Tol | | °C |
| Heating/Warmer | Tbiv | N/A N/A | °C | Heating/Warmer | Tol | | °C |
| Heating/Colder | Tbiv | N/A N/A | °C | Heating/Colder | Tol | | °C |
| Cycling interval capacity Cycling interval efficiency | |
| Item Symbol Value Unit | | | | Item Symbol Value Unit | | | |
| For cooling | Pcycc | N/A N/A | kW | For cooling | EERcyc | | - |
| For heating | Pcycc | N/A N/A | kW | For heating | COPcyc | | - |
| Degradation coefficient cooling | Cdc | 0.25 0.25 | - | Degradation coefficient cooling | Cdh | | - |
| Electric power input in power modes other than ‘active mode’ | Annual electricity consumption |
| Item Symbol Value Unit | | | | Item Symbol Value Unit | | | |
| Off mode (Cooling/Heating) | P_OFF | 5.0/5.0 500 W | Cooling | Q_CE | | kWh/a |
| Standby mode (Cooling/Heating) | P_SB | 5.0/5.0 2833 W | Heating/Average | Q_HE | | kWh/a |
| Thermostat-off mode (Cooling/Heating) | P_TO | 7.0/28.0 N/A W | Heating/Warmer | Q_HE | | kWh/a |
| Crankcase heater mode (Cooling/Heating) | P_CK | 0.0/0.0 N/A W | Heating/Colder | Q_HE | | kWh/a |
| Capacity control Other items | |
| Item Y/N Item Symbol Value Unit | | | | |
| Fixed | No 63.0/68.0 | Sound power level (Indoor/Outdoor) | LWA | | dB(A) |
| Staged | No | Global warming potential | GWP | 2088 | kgCO2eq. |
| Variable | Yes | Rated air flow (Indoor/Outdoor) | - | 1700/3600 | m3/h |
| Contact details for obtaining more information | FUJITSU GENERAL LIMITED3 3 17, Suenaga, Takatsu ku, kawasaki, 213 8502, Japan |