Product Type Split System Air Conditioner (Single Split, Ducted)
Brand Fujitsu General
Indoor Unit Model ARHG36LMLA
Outdoor Unit Model AOHG36LATT
Cooling Capacity (Nominal) 10.0 kW (at 35°C outdoor)
Heating Capacity (Nominal at -7°C) 8.85 kW (average climate)
Seasonal Energy Efficiency Ratio (SEER) Not specified
Seasonal Coefficient of Performance (SCOP) Not specified
Sound Power Level (Indoor) 61 dB(A)
Global Warming Potential (GWP) 2088 kg CO2 eq
Rated Air Flow (Indoor) 800 m³/h
Rated Air Flow (Outdoor) 1032 m³/h
Power Consumption (Off Mode) 19.0 W
Power Consumption (Standby) 19.0 W
Power Consumption (Thermostat-off) 4.0 W
Refrigerant R410A
Compressor Type Inverter (Variable Capacity)
Bivalent Temperature (Heating) -7°C
Degradation Coefficient 0.25
Capacity Control Variable

Frequently Asked Questions - ARHG36LMLA FUJITSU

What is the cooling capacity of the Fujitsu ARHG36LMLA?
The cooling capacity is 10.0 kW at an outdoor temperature of 35°C.
What are the sound levels of the indoor unit?
The indoor unit has a sound power level of approximately 61 dB(A).
What type of refrigerant does this air conditioner use?
The refrigerant is likely R410A with a global warming potential of 2088 kg CO2 eq.
How do I clean the air filter?
Clean the air filter every 2 weeks by washing with water and drying before reinserting.
What is the recommended maintenance schedule?
Annual professional maintenance is recommended to ensure optimal performance.
Can this unit be used for heating in cold climates?
Yes, it has heating capacity down to -7°C bivalent temperature.
What is the power consumption in standby mode?
Standby power consumption is 19.0 W.
How do I reset the unit after a power failure?
Turn off the unit, wait 5 minutes, then turn on again.
What should I do if the unit is not cooling properly?
Check the air filter, ensure the outdoor unit is unobstructed, and verify the thermostat settings.
Is the unit compatible with a smart thermostat?
Yes, it can be controlled via a standard remote, but compatibility with smart thermostats may require additional adapters.

User questions about ARHG36LMLA FUJITSU

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Séparateur in PDF format for free! Find your manual ARHG36LMLA - FUJITSU and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ARHG36LMLA by FUJITSU.

USER MANUAL ARHG36LMLA FUJITSU

Infomation sheet (Lot. 10)

This information includes the results of calculation of the seasonal energy consumption to the Commission Regulation(EU) No.206/2012 and No.626/2011. Information to identify the model(s) to which the information relates to:

TYPE :AIR CONDITIONER
SINGLE SPLIT
DUCT
indoor unitARHG36LMLA
outdoor unitAOHG36LATT
BRANDGENERAL

N/A = Not A p l i c a b l e

Function
Cooling AverageYes Yes
Heating WarmerYes No
ColderNo
Design load Seasonal efficiency
Item SymbolValueUnitItemSymbol Value Unit
CoolingPdesign1c0.05kW0CoolingSEER-
Heating/AveragePdesign1c0.04kW0Heating/AverageSCOPA-
Heating/WarmerPdesignNc/AN/KAWHeating/WarmerSCOPW-
Heating/ColderPdesignNc/AN/KAWHeating/ColderSCOPC-
Cooling
Declared capacity for cooling.at indoor temperature 27 (19) °C andDeclared energy efficiency ratio.d aotutidnodoorort etnepmepreartautruer eTj27 (19) °C and
Item SymbolValueUnitItem SymbolValueUnit
Tj = 35°CPdc10.002W5Tj = 35°CEERd-
Tj = 30°CPdc7.374kW3Tj = 30°CEERd-
Tj = 25°CPdc4.747kW8Tj = 25°CEERd-
Tj = 20°CPdc5.459kW4Tj = 20°CEERd-
Heating/Average
Declared capacity for heating/Average at indoor temperature 20 °C and outdDsee cal saorne d capacity for heating/Average part tiemndoe or rattuer nep etr jature 20 °C and outd
Item SymbolValueUnitItemSymbol Value Unit
Tj = -7°CPdh8.852k W1Tj = -7°CCOPd-
Tj = 2°CPdh5.384k W0Tj = 2°CCOPd-
Tj = 7°CPdh5.055k W6Tj = 7°CCOPd-
Tj = 12°CPdh5.646k W3Tj = 12°CCOPd-
Tj = b i valent tempera l u Pdh8.852k W1Tj = b i valent temperat uCrOPd-
Tj = operating limitPdh8.202k W3Tj = operating limitCOPd-
Heating/Warmer
Declared capacity for heating/Warmer at indoor temperature 20 °C and outdoDeacslonr,ed capacity for heating/Warmer part tiennpoeorrattuermep eTrjature 20 °C and outdo
Item SymbolValueUnitItem SymbolValueUnit
Tj = 2°CPdhN/AN/KAWTj = 2°CCOPd-
Tj = 7°CPdhN/AN/KAWTj = 7°CCOPd-
Tj = 12°CPdhN/AN/KAWTj = 12°CCOPd-
Tj = bivalent temperatu PdhN/AN/KAWTj = bivalent temperat uCrOePd-
Tj = operating limitPdhN/AN/KAWTj = operating limitCOPd-
Heating/Colder
Declared capacity for heating/Colder at indoor temperature 20 °C and outdo part tlennpoorrattuerne petrjature 20 °C and outd
Item SymbolValueUnitItem SymbolValueUnit
Tj = -7°CPdhN/AN/KAWTj = -7°CCOPd-
Tj = 2°CPdhN/AN/KAWTj = 2°CCOPd-
Tj = 7°CPdhN/AN/KAWTj = 7°CCOPd-
Tj = 12°CPdhN/AkWTj = 12°CCOPdN/A-
Tj = bivalent temperatu PdhN/AN/KAWTj = bivalent temperat uCROPd-
Tj = operating limitPdhN/AN/KAWTj = operating limitCOPd-
Tj = -15°CPdhN/AN/KAWTj = -15°CCOPd-
Bivalent temperature Operating limit temperature
Item SymbolValueUnitItem SymbolValueUnit
Heating/AverageTbiv-715°CHeating/AverageTol°C
Heating/WarmerTbivN/AN/%Heating/WarmerTol°C
Heating/ColderTbivN/AN/%Heating/ColderTol°C
Cycling interval capacity Cycling intervalval efficiency
Item SymbolValueUnitItem SymbolValueUnit
For coolingPcycc N/AN/AWFor coolingEERcyc-
For heatingPcycc N/AN/AWFor heatingCOPcyc-
Degradation coefficient Cdoc| Dn@50.25Degradation coefficient Cdoc| Dn@50.25Degradation coefficient Cdoc-
Electric power input in power modes of ther than 'active mode' Annual electric
Item SymbolValueUnitItem SymbolValueUnit
Off mode (Cooling/Hea ti Pd g)19.0/19.W06Qo8ol ing Q_E k Wh / a
Standby mode (CoolingHPa3tihg.)0/19.W03Hea7ting/Average Q_E k Wh / a
Thermostat-off mode (CoBloing/Hea4i Mg N/Heating/Warmer Q_E k Wh / a
Crankcase heater mode (Boxoli0n g//He a0MngHeating/Colder Q_E N/kAWh / a
Capacity control Other items
Item Y/N Item SSymbol Value Unit
FixedNoSound power level (Indolo/dolo/O615 d or0JB(0A)
StagedNoGlobal warming pot entiaGWP2088gCO
VariableYesRated air flow (Indoo r / Outdolo800/1032/10