RM0011 - Smoke detector ABUS - Free user manual and instructions
Find the device manual for free RM0011 ABUS in PDF.
| Product type | Smoke detector |
| Brand | ABUS |
| Model | RM0011 |
| Sensor type | Photoelectric |
| Power supply | 9V battery (included) |
| Battery life | Approximately 1 year |
| Detector diameter | 120 mm |
| Detector height | 40 mm |
| Weight | 150 g |
| Alarm volume | 85 dB at 3 m |
| Test button | Yes |
| Mute/ hush function | Yes |
| Low battery warning | Chirping sound |
| Indicator LED | Red for alarm, green for normal |
| Interconnectivity | Wireless, up to 20 units |
| Operating temperature | 0°C to 40°C |
| Operating humidity | 10% to 90% non-condensing |
| Compliance | EN 14604 |
| Maintenance | Vacuum dust monthly; replace battery annually |
| Spare parts | 9V battery (standard type) |
| Repairability | Not user-serviceable; replace unit after 10 years |
Frequently Asked Questions - RM0011 ABUS
User questions about RM0011 ABUS
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Smoke detector in PDF format for free! Find your manual RM0011 - ABUS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RM0011 by ABUS.
USER MANUAL RM0011 ABUS
Security Tech Germany
Operating and Installation Instructions

text_image
ABUSSecurity Tech Germany
Photoelektric Radio Smoke Detector RM 04 Li VdS Radio

text_image
VdSG 203075

text_image
CE07680768-CPD-20432
EN 14604:2005
Dear Customers,
Congratulations; you have chosen well.
This ABUS radio smoke detector is equipped with an innovative and reliable radio system. Through the use of the latest and most reliable components, this detector has a large range and volume.
Another advantage of this radio smoke detector is the coding switch. This makes radio interference from other radio systems practically an impossibility.
This smoke detector is VdS approved and guarantees the highest quality and manufacturing standards!
Please carefully read through these instructions before starting up!
Functionality and Characteristics
This radio-networked smoke detector with volume switch operates according to the optical principle and has a measurement chamber in which penetrating smoke particles are detected. If the alarm threshold is exceeded, a clamorous alarm sounds. In networked smoke detectors, the alarm is recognized by all other detectors with the same code. These detectors then also sound their alarms. The alarm remains activated for as long as smoke is found in the detection chamber. The alarm is not turned off until the measurement chamber is smoke-free.
• Monitoring area: 40 m ^2 within one room
- Battery-operated (1x 9V battery)
- Alarm memory function
• Automatic recognition of battery level
- Battery case monitor
(smoke detector can only be installed with battery inserted)
- Simple cover assembly
What to do in case an alarm sound is triggered
- Immediately leave the residence! Every second counts; do not lose any time to getting dressed or carrying objects. Use an escape route!
- Do not open any doors without first inspecting the surface. If it is hot or smoke can be seen underneath the door, do not open the door! Use an alternative escape route. If the surface is cool, press a shoulder against it, open it slightly and be prepared to close the door if heat and smoke enter.
- If the air is smoky, stay close to the floor and breath through a damp cloth if possible.
- Once out of the building, go to the agreed upon meeting point and do not return to the house.
- Call the fire department outside the burning building.
Installation locations
- Place the smoke detector directly on the ceiling in the center of the room.
- Preferred rooms are living rooms, bedrooms and children's rooms. If there are multiple bedrooms, install additional smoke detectors in each bedroom.
- Smoke detectors should also be installed in hallways in order to monitor them, as fires can easily be ignited in stairways in particular (chimney effect). Several detectors may be necessary in long hallways.
The distance between the detectors should not be greater than 8 m. - When installing on the ceiling, ensure that the detector is at least 15 cm from the side wall and at least 50 cm from each corner.
Avoid these locations for installation!
- Spots where there are greater temperature fluctuations than the operating temperature range (+4°C to +45°C).
- Locations where draft air can keep smoke away from the detector, such as next to windows, doors or ventilation shafts.
- Spots where moisture, increased air humidity or exhaust emissions can trigger false alarms, such as in kitchens, bathrooms or garages.
- Locations that can negatively influence the functionality of the detector due to high dust and contamination loads.
- At the highest point of "A"-shaped ceilings. The distance to the peak of the ceiling should be at least 30 cm.

Installation and Attachment
- Loosen smoke detector from the detector base (by turning counter-clockwise) and mark the drill holes through the base.
• Install the necessary drill holes and wall anchors and screw down detector base. - Insert battery and fasten smoke detector on detector base (by turning clockwise). The detector is equipped with a safety device that prevents attachment of the detector without a battery.
- If the smoke detector cannot be fastened on the base, ensure that the battery is properly connected.
Start-Up and Function Test
- The smoke detector is operationally ready as soon as the battery is inserted. A red display light is located under the test button, which blinks once per 8 seconds and shows that the battery is correctly installed and creating enough current to trigger the alarm.

For your own safety check your smoke detector every four weeks. In the event the smoke detector does not function it must for your own safety be exchanged immediately.
- Alternatively, the Test Spray RM (in the ABUS product line) can be used on the smoke detector for testing. The siren sounds and the functionality of the smoke detector is tested (except for radio transmission).
- The sensitivity of the smoke detector is simultaneously reduced and 2 short beeping sounds can be heard.
- To test the radio alarm function, the test button must be pressed for longer than 3 seconds (the smoke detector is now functioning in quiet mode). The test LED then lights up continually for approx. 40 seconds.
This indicates radio transmission. After a short delay, an alarm sounds on all other smoke detectors for approx. 25 seconds.
Networking of radio smoke detectors
- All radio smoke detectors networked with one another must be set to the same radio code.
- The detectors are always delivered from the factory with an identical code. In order to prevent interference from similar detectors, this code should be changed in all detectors before start-up.
- Tip: Change the code again if a false alarm is triggered for no apparent reason. It is possible that an identical detector has been installed in the neighboring area.
• After a new code has been set, the entire system must be tested (see Test).

text_image
0123459789A A B C D E F 0Note:
Ensure that the selected code is entered precisely.
An appropriate screwdriver should be used to make the adjustment!
Special code "0"
- The code "0" has a priority function.
- If the code "0" is set on a radio smoke detector, the detector can receive the alarm signals from detectors with all other codes, with a delay of approx. 3 min., and transmits an alarm directly to all other detectors that are set with code "0". This function can be useful for the widest variety of applications, such as in a multi-family house!
- If an alarm is detected in a radio smoke detector that is set with code "0", this detector transmits the alarm to all other detectors without delay.
- Example: A radio smoke detector in the staircase (code 0) detects smoke and reports it to all radio smoke detectors in its radio transmission range. This means that the detectors on the ground floor (Code 1, for example), as well as all other units (Code 2 ...) are signaled, as well.
Alarm memory function
If a smoke alarm triggers due to smoke or source of interference (but not from pressing the test button), then the triggering is saved on this smoke detector for up to 12 hours.
The saved triggering is then indicated every 8 seconds by a beep and simultaneous blinking.
The functionality of the smoke detector is not influenced during this time. The memory can be cleared by pushing the test button until an alarm sound can be heard.
Volume switch/Sensitivity reduction
The sensitivity reduction can be useful in certain situations (when smoking a cigarette, for example).
- If there is risk of a false alarm, the sensitivity can be reduced for approx.
10 minutes with the help of the test button. To do so, press the test button for approximately 2 to 3 seconds. The LED then blinks a second time every 8 seconds.
• After approx. 10 minutes, the detector functions at normal sensitivity again. - The sensitivity can also be manually reset to the normal state by pressing the button again.
Replacing the battery

If the battery should be weak, the smoke detector will emit a beeping sound once per minute (for approx. 30 days) as a reminder to replace the battery (battery charge condition-warning). When hearing this signal the battery must be changed for your own safety immediately. The smoke detector remains fully functional during this period.
- The detector automatically carries out a recalibration and self-test after battery replacement; that is, the detector registers light contamination to itself, but its smoke sensitivity remains identical. A longer beep sounds after this process.
We recommend using the following high-quality alkaline batteries:
Duracell # MN 1604, Energizer Ultra+, Energizer Industrial, Varta Longlife or a corresponding lithium battery.
Used batteries do not belong in household garbage – please dispose of them environmentally correctly!
Alarm and Error Signal
- If the alarm threshold is exceeded, a clamorous alarm sounds. The alarm remains activated for as long as smoke is found in the detection chamber. The alarm is not turned off until the measurement chamber is smoke-free.
- This device creates two different alarm tones, to differentiate WHERE and by WHICH device an alarm is triggered. The triggering alarm (primary alarm) is significantly different from all other alarm sounds (secondary alarm).
• The alarm can be deactivated - By pressing the test button (front) on one of the secondary detectors; only this device is deactivated.
- Or by pressing the test button on the primary detector; after a delay of approx. 20 sec., all alarm tones are deactivated.
- If the smoke detector should have a technical fault, then this will be indicated by 2 or 3 short tones.
- Technical faults can be caused by dust, external electromagnetic faults or extremely bright light sources. Please clean the detector as described under the item "Maintenance".
- If the error is not resolved by cleaning or a change of position, please contact the vendor.
Maintenance
- Dusty detectors must be cleaned. Dust deposits in the air slots of the detector can be vacuumed or blown out. If necessary, the dust can be removed with a brush.
- The surface can be cleaned with a towel, lightly dampened with soap suds.
- Do not use chemicals or abrasives.

Please note:
Smoke detectors help save lives. For your own safety regularly test the battery and the function of the smoke detector. Remember that the smoke detector cannot prevent a fire, but rather can only signal in case of a fire. Out of concern for your own safety, please replace the smoke detector every 10 years at latest!
Warranty Statement
ABUS products are designed, manufactured and tested according to applicable regulations with great care. ABUS August Bremicker Söhne KG, Altenhofer Weg 25, 58300 Wetter grants a five-year warranty for the RM04 Li VdS Radio smoke detector irrespective of legal warranty claims, beginning with the date of sale of the smoke detector to the end consumer.
The warranty extends solely to defects caused by material or manufacturing errors. If a material or manufacturing defect is shown to exist, the smoke detector will be repaired or replaced according to the warrantor's discretion. In this case, the warranty ends with expiration of the original warranty period. Further claims are expressly excluded.
Expressly excluded from the warranty are supplied batteries. ABUS is not liable for defects and damages that occur due to external influences (such as transport, outside forces, faulty operation), improper use, normal wear and tear or through a failure to observe this operating manual.
The original sales receipt with date of purchase and a brief written description of the error must be enclosed with the faulty smoke detector when submitting a warranty claim.
If you should discover a defect on the smoke detector that was already present upon purchase, please contact your salesperson directly within the first two years.
| Technical Data: RM 04 Li VdS Radio | |
| Smoke detection: Photoelectric reflection | |
| Acoustic power level: Min. 85dB (3 m) | |
| Volume switch Sensitivity reduction: | 10 min. |
| Temperature range: +4 to +45 degrees Celsius | |
| Power supply: 1x9V lithium block battery | |
| Battery service life: up to 2 years | |
| Battery level warning indicator: At least 30 days | |
| Current consumption: Max. 20 micro A | |
| Height: | 33 mm |
| Diameter: | 106 mm |
| Weight: | 160 Grams |
| Number of networkable devices: | Unlimited |
| Number of codes: | 16; of those, 1 priority code |
| Radio range: | Depending on local conditions |
| Radio frequency: | 434.33 MHz |
| Radio authorization: | R & TTE CE |
| Other: | Self-test & recalibration |
Technical and color changes reserved. Not liable for errors and misprints.
Conformity Statement
"ABUS August Bremicker Söhne KG, Altenhofer Weg 25, 58300 Wetter hereby declares that the RM04 Li VdS Radio device conforms to the basic requirements and other relevant regulations of the EMC guidelines 1999/5/EG."
The conformity statement can be found at www.abus.de
Security Tech Germany
Security Tech Germany
Fotoelektrisk radiobrandvarnare RM 04 Li VdS radio

text_image
VdSG 203075

text_image
CE07680768-CPD-20432
EN 14604:2005
Bäste kund!