Witt WCKSF5S - Kitchen scale

WCKSF5S - Kitchen scale Witt - Free user manual and instructions

Find the device manual for free WCKSF5S Witt in PDF.

📄 44 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Witt WCKSF5S - page 12
View the manual : Dansk DA English EN Suomi FI Norsk NO Svenska SV
Pick your language and provide your email: we'll send you a specifically translated version.
Type of product Kitchen scale
Brand Witt
Model WCKSF5S
Dimensions (approx.) 20 x 15 x 2 cm
Weight (approx.) 300 g
Power source 2 x AAA batteries (not included)
Maximum capacity 5 kg
Precision 1 g
Units of measurement g, kg, lb, oz, ml, fl.oz
Display type LCD screen
Tare function Yes
Auto-off Yes, after 2 minutes of inactivity
Low battery indicator Yes
Overload indicator Yes
Material Tempered glass platform, plastic body
Cleaning Wipe with a damp cloth; do not immerse in water
Safety warnings Keep away from water; do not drop; replace batteries if leaking
Spare parts / Repairability Batteries are user-replaceable; no other spare parts available
Manual languages EN, DA, FI, NO, SV
General information Witt WCKSF5S kitchen scale for precise weighing in the kitchen

Frequently Asked Questions - WCKSF5S Witt

How do I turn on the Witt WCKSF5S kitchen scale?
Place the scale on a flat, stable surface. Press the ON/OFF button. The display will show 0 g or 0:00. If not, check the batteries.
How do I use the tare function?
Place an empty container on the scale, then press the TARE button. The display will reset to zero. Add ingredients to the container for accurate net weight.
How do I change the unit of measurement?
Press the UNIT button repeatedly to cycle through available units: g, kg, lb, oz, ml, fl.oz. The current unit is shown on the display.
What does 'EEEE' or 'O-Ld' mean on the display?
EEEE indicates an overload or error. Remove the weight immediately to avoid damage. O-Ld means the scale is overloaded. The maximum capacity is 5 kg.
How do I clean the Witt WCKSF5S scale?
Wipe the surface with a soft, damp cloth. Do not use abrasive cleaners or immerse the scale in water. Dry thoroughly before use.
What batteries does the scale use and how do I replace them?
The scale requires 2 x AAA batteries (not included). Open the battery compartment on the bottom, insert the batteries correctly (+/-), and close the lid.
Why does the scale turn off automatically?
The scale has an auto-off feature to conserve battery life. It will turn off automatically after about 2 minutes of inactivity. Press the ON/OFF button to restart.
Can I measure liquid volume with this scale?
Yes, in ml and fl.oz modes. Use a container on the scale, tare it, then add liquid. The density conversion is approximate for water-based liquids.
What should I do if the display is dim or shows 'Lo'?
A dim display or Lo symbol indicates low batteries. Replace them with new AAA batteries to ensure accurate readings.
How accurate is the Witt WCKSF5S kitchen scale?
The scale has a precision of 1 gram (0.1 oz). For best accuracy, place the scale on a level, non-slip surface and avoid weighing in direct sunlight or near heat sources.

User questions about WCKSF5S Witt

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Kitchen scale in PDF format for free! Find your manual WCKSF5S - Witt and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. WCKSF5S by Witt.

USER MANUAL WCKSF5S Witt

Witt Classic Kitchen Scale foldable

WCKSF5S

Witt WCKSF5S - Witt Classic Kitchen Scale foldable - 1

natural_image Close-up of a metallic handheld device with a digital display showing a measurement (no text or symbols visible)

TARE-FUNKTION

UDSKIFT BATTERI

Witt WCKSF5S - UDSKIFT BATTERI - 1

flowchart
graph LR
    A["Circle Component"] --> B["Circular Device"]
    B --> C["Empty Device"]
natural_image Symbol of a trash bin crossed with a diagonal line, representing no waste or discharge (no text or labels)

CLEANING AND MAINTENANCE 15

WARRANTY 16

SERVICE 17

For proper use and maintenance, please read this manual carefully

SPECIFICATIONS

  • High precision strain gauge sensor system
  • Touch panel switch
  • Capacity:: 5 kg / 1 g
  • Stainless steel platform
  • Units: g, oz/ ml / lb:oz (ml for milk or water)
  • Tare function and auto zero resetting
  • Low power / Over-load indication
  • Division: kg/lb
  • 1 x 3V CR2032 battery (included)
  • Manual on /Auto off / Manual off

SAFETY AND USAGE INFORMATION

  • Placing the scale on a hard and flat surface to ensure the greatest accuracy and replicability.
  • Do not drop or subject the scale to shocks as this may damage the unit.
  • Do not use chemical abrasive cleaners.
  • Clean the scale with a damp cloth, please don't put it in a wet or hot environment.
  • Please remove the battery from the scale if it has not been used for a long period.
  • If it does not work when you open the scale, please check the battery and ensure the battery is with correct polarity. Please check if the battery needs to be changed when the scale have been used for a long time, then try to start it again.
  • This scale is for family use only and should not be used commercially for any reasons at all.
  • Do not allow water to get inside the scale.
  • Do not store the scale in an upright position.

MAIN FUNCTION

MODE key: Press to change the unit (g/oz/lb:oz/ml)

MODE TARE

Tare-key: On/Off function Tare function

SWITCH OFF

  • Press "TARE" for 2 seconds and the scale will switch off.
  • The scale will automatically switch off after no operation in approximate 60 seconds.

UNIT CHANGES (g/oz/lb:oz/ml)

- Press "MODE" once, the unit will be exchanged from g / oz / lb:oz / water (ml) / milk (ml).

104. MODE 365 - 104

MI measurement

Put a container on the platform, press "TARE" to clear the weight of the container. Press "MODE" till display shows ml. Then put water or milk into the container and check the volume.

OPERATION

WEIGHING

Step 1: Place the scale on a hard and flat surface.
Step 2: Press "TARE" once, the LCD display will show zero.
Step 3: Put the food on the platform, the weight will be displayed.

0. > 208.

TARE FUNCTION

Step 1: Put the container on the platform, the LCD display will show the weight of the container.

Step 2: Press "TARE" to clear the weight of the container (reset to zero). Then put the food into the container, the LCD display will show the weight of food only. Repeat press "TARE" to weight more different food.

Step 3: The LCD display will show the negative value of container if you remove the food and container from the platform together. Please press "TARE" again, the display will show zero in a few seconds.

0. → 68. → 0. → 275.

INSERT THE BATTERY

Witt WCKSF5S - INSERT THE BATTERY - 1

flowchart
graph LR
    A["Circle with top"] --> B["CR2023"]
    B --> C["Box with bottom"]
  • Open the battery cover.
    • Install 1 x 3 CR2032 battery as shown.
  • After installing the battery, put back the battery co er and push the cover backward.
  • Please be aware that incorrect polarity can cause damage on the electronic parts.

ERROR INDICATIONS

Low battery indication

When low power, display will show::

lo

Unstable

When the scale is not stable before weighing, display will show:

un5t

Over-load indication

When the scale is over-loaded [more than 5 kg], the display will show:

EEEE

CLEANING AND

MAINTENANCE

  • Please use a damp cloth to clean the scale. Do not allow water to get inside scale.
  • Do not use chemicals to clean the scale.

Witt WCKSF5S - MAINTENANCE - 1

natural_image Symbol of a trash bin crossed with a diagonal line, representing waste or discharge (no text or labels)

Please dispose of it at your local community waste collection / recycling centre or contact your dealer for advice. Ensure that it presents no danger to children while being stored for disposal.

Witt WCKSF5S - MAINTENANCE - 2

WARRANTY

A two year guarantee on manufacture and material defects is granted on your new appliance valid from the documented purchase date. The guarantee includes materials, salary and transport. When contacting service please state the appliance model and serial number.

The guarantee does not cover:

  • Defects and damages which are not caused by manufacture and material defects.
  • If original spare parts have not been used.
  • If the instructions in the manual have not been carried out.
  • If the installation has not been carried out according to this manual.
  • If unauthorized personnel has carried out installation or repair word.

Transport damages

A transport damage observed when the dealer delivers the appliance at the customer is solely a matter between the customer and the dealer. If the customer has carried out the transport alone the manufacture / supplier cannot be held responsible for transport damages. All transport damages must be reported no later than 24 hours after delivery otherwise all claims will be rejected.

Unnecessary service visits

If a service technician is called out to a defect and the customer could have corrected the defect without help e.g. by following the instructions within this manual or by changing a fuse the customer will be charged all service costs – even under guarantee.

Commercial purchase

Commercial purchases are any purchase of appliances not used in a domestic household but instead are used for commercial purposes e.g. in a restaurant, café etc. or used to rent out or used for any other purpose including several users. In case of commercial purchase no guarantee is granted on this appliance since this is only meant for domestic household use.

SERVICE

For service and spare parts in England and Ireland please call below-mentioned number and you will be directed accordingly or send us an email. Witt UK & Ireland Ltd. (44) 148 351 6633 / info@witt.dk

INNHOLD

SPESIFIKASJONER 18

VIKTIGE SIKKERHETSANVISNINGER 19

HOVEDFUNKSJON 21

BETJENING 22

FEILMELDING 23

RENGJ∅RING OG VEDLIKEHOLD 23

REKLAMASJÓN 24

SERVICE 26

SPESIFIKASJONER

TARE-FUNKSJON

Trinn 1: Plasser beholderen på plattformen. LCD-displayet viser beholderens vekt.

flowchart
graph LR
    A["Circle Component"] --> B["Circular Device"]
    B --> C["Empty Device"]

INNEHÅLLSFÖRTECKNING

SPECIFICATIONER 27

VIKTIGA SÄKERHETSANVISNINGAR 28

GENERELLT 29

HUVUDFUNKTION 30

ANVÄNDNING 31

FELMEDDELANDE 32

RENGÖRING OCH UNDERHÅLL 32

REKLAMATION 33

SERVICE 35

SPECIFIKATIONER

- Högprecisionssensor-system

- Touch knapp

- Viktkapacitet: 5 kg / 1 g

Tara-knapp: Av/på - funktion Tara-funktion

STÄNG AV PRODUKTEN

TARE-FUNKTION

natural_image Line drawings of four different cooking utensils or containers, no text or symbols present

Witt WCKSF5S - STÄNG AV PRODUKTEN - 1

BYT BATTERI

Witt WCKSF5S - BYT BATTERI - 1

flowchart
graph LR
    A["Circle Component"] --> B["Circular Device"]
    B --> C["Empty Device"]
natural_image Symbol of a trash bin crossed with diagonal lines, no text or numbers present

TAARAUSTOIMINTO

flowchart
graph LR
    A["Circle with ring"] --> B["CR2003"]
    B --> C["Box with battery"]
natural_image Symbol of a trash bin with crossed lines indicating no waste or restriction (no text or labels)
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Witt

Model : WCKSF5S

Category : Kitchen scale