Product Type RJ45/RJ11 Data Outlet (Uncategorized)
Brand Hager
Model WGCT2RJ6NM
Application Data transmission in local area networks and telephone/data applications
Installation Flush-mounted in standard wall boxes (recommended depth ≥ 35 mm), indoor use only
Environmental Protection Indoor areas with no drip or spray water
RJ45 Voltage Proof (Contact-to-Contact) 1000 V DC or AC peak
RJ45 Current Rating 0.75 A
RJ45 Insulation Resistance ≥ 500 MΩ at 100 V DC
RJ45 Signal Contact Resistance ≤ 20 mΩ
RJ45 Connection Type IDC terminals
RJ45 Design Standard IEC 60603-7
RJ45 Color Code TIA/EIA 568-B.2 (A and B)
RJ45 Cat.5e Bandwidth Max. 100 MHz
RJ45 Cat.5e Conductor Diameter 0.51 ... 0.64 mm (AWG 24-22), solid
RJ45 Cat.5e Standard ISO/IEC 11801 (UTP)
RJ45 Cat.6 Bandwidth Max. 250 MHz
RJ45 Cat.6 Conductor Diameter 0.51 ... 0.64 mm (AWG 24-22), solid
RJ45 Cat.6 Standard ISO/IEC 11801, 2nd edition (UTP)
RJ45 Cat.6A Bandwidth Max. 500 MHz
RJ45 Cat.6A Conductor Diameter 0.41 ... 0.64 mm (AWG 26-22), solid
RJ45 Cat.6A Standard ISO/IEC 11801, edition 2.2 (UTP)
RJ11 Compliance YD/T 577
Safety Installation Must be installed by qualified electrician according to local standards

Frequently Asked Questions - WGCT2RJ6NM HAGER

What type of cable is compatible with the Hager WGCT2RJ6NM?
The device accepts solid copper conductors with diameters 0.51–0.64 mm (AWG 24-22) for Cat.5e and Cat.6, and 0.41–0.64 mm (AWG 26-22) for Cat.6A, unshielded twisted pair (UTP).
What is the maximum transmission bandwidth for the WGCT2RJ6NM?
It depends on the module: Cat.5e: 100 MHz, Cat.6: 250 MHz, Cat.6A: 500 MHz.
Can I install the Hager WGCT2RJ6NM outdoors?
No, it is only suitable for indoor use in areas with no drip or spray water.
What is the correct way to strip the cable for RJ45 termination?
Strip 30 mm of the cable jacket to expose the pairs for IDC termination.
Which colour code should I use for RJ45 wiring?
You can use either TIA/EIA 568A or TIA/EIA 568B. The pin assignment table is provided in the manual.
What tools are needed for installation?
You will need a flat-blade screwdriver to remove frames, and a punch-down tool for IDC terminals.
How many jacks does the WGCT2RJ6NM have?
The model WGCT2RJ6NM appears to be a combination of one RJ45 and one RJ11 outlet, as shown in the installation example.
Is the Hager WGCT2RJ6NM shielded?
The modules are unshielded (UTP) according to the standards listed.
Can I use this outlet for telephone connections?
Yes, the device includes an RJ11 module specifically designed for telephone and data applications.
What is the minimum wall box depth required?
A standard wall box with a depth of at least 35 mm is recommended for flush-mounted installation.

User questions about WGCT2RJ6NM HAGER

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Network Socket in PDF format for free! Find your manual WGCT2RJ6NM - HAGER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. WGCT2RJ6NM by HAGER.

USER MANUAL WGCT2RJ6NM HAGER

Electrical equipment must only be installed and assembled by a qualified electrician in accordance with the relevant installation standards, regulations, directives and safety and accident prevention directives of the country.

Failure to comply with these installation instructions may result in damage to the device, fire or other hazards.

Function

The RJ45 outlets are used for data transmission in local area networks. The RJ11 outlets are designed for telephone and data applications. Each jack is equipped with a dust protection slider.

Correct use

  • For the flush-mounted installation in standard wall boxes (recommended wall box depth ≥ 35 mm).
  • Only suitable for use in indoor areas with no drip and no spray water.

Technical data

RJ45 outlets

Voltage proof (contact-to-contact): 1000 V DC or AC peak

Current rating: 0.75 A

Insulation resistance: ≥ 500 M at 100 V DC

Signal contact resistance: ≤ 20 m

Type of connection: IDC terminals

Design: according to IEC 60603-7

Colour code A and B: according to TIA/EIA 568-B.2

RJ45 Cat.5e modules

Transmission bandwidth: max. 100 MHz

Conductor ∅ (solid): 0.51 ... 0.64 mm (AWG 24-22)

Cat.5e, unshielded (UTP): according to ISO/IEC 11801

RJ45 Cat.6 modules

Transmission bandwidth: max. 250 MHz

Conductor ∅ (solid): 0.51 ... 0.64 mm (AWG 24-22)

Cat.6, unshielded (UTP): according to ISO/IEC 11801, 2nd edition

RJ45 Cat.6A modules

Transmission bandwidth: max. 500 MHz

Conductor ∅ (solid): 0.41 ... 0.64 mm (AWG 26-22)

Cat.6A, unshielded (UTP): according to ISO/IEC 11801, edition 2.2

RJ11 outlet

Compliance: YD/T 577

Information for electricians

Installation and electrical connection

Preparing the device for installation

(for example "RJ11 + RJ45 outlet")

1A
Frame Notches

Hager Muse

Hager Inspire1B
Frame Cover plate Notches

  • Carefully loosen the frame on the notches with a flat-blade screwdriver. Lift up and remove the frame (1A/1B).
    ■ Hager Inspire: Remove the cover plate also with a flat-blade screwdriver (1B).

Connecting the RJ45 data module

■ Remove the cover plate of the data module with a flat-blade screwdriver.

2A
UTP 30 mm

  • Strip 30 mm of cable jacket (2A).
    ■ Position and terminate first pair according to colour code A or B:

RJ45 pin assignment TIA/EIA 568B TIA/EIA 568A

HAGER WGCT2RJ6NM - Connecting the RJ45 data module - 21 white/orange white/green
2 orange green
3 white/green white/orange
4 blue blue
5 white/blue white/blue
6 green orange
7 white/brown white/brown
8 brown brown

As with the first pair position and terminate each subsequent pair one at a time until termination is complete.
- Fix the cover plate back to the module.

Connecting the RJ11 telephone module

3A
10 mm

  • Strip 10 mm of cable jacket (3A).
    ■ Position first pair according to colour code:

RJ11 pin assignment

HAGER WGCT2RJ6NM - Connecting the RJ11 telephone module - 22 blue/white
3 white/blue
4 white/red
5 red/white

- Fix the cover plate back to the module.

HAGER WGCT2RJ6NM - Connecting the RJ11 telephone module - 3

Checking of the installation:

A functional test of the installation should be made for each data or telephone outlet.

Installing the device into the wall box

(for example "RJ11 + RJ45 outlet")

4
HAGER WGCT2RJ6NM - Installing the device into the wall box - 1

natural_image Technical diagram of a mechanical assembly with a bracket and tool, showing no text or symbols

■ After wiring, fix the device with the two screws attached into the wall box (4).

Assembling the covers

(for example "RJ11 + RJ45 outlet")

5A
5A Hager Muse Frame

Hager Muse

5B
5B Hager Inspire Cover plate Frame

Hager Inspire

■ Hager Muse: Snap the frame onto the device (5A).
■ Hager Inspire: Place the cover plate in the correct position and fix with frame (5B).

2-5gang frames are available for multiple combinations.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : HAGER

Model : WGCT2RJ6NM

Category : Network Socket