HAGER WGCXT1RJ5KB - Network Socket

WGCXT1RJ5KB - Network Socket HAGER - Free user manual and instructions

Find the device manual for free WGCXT1RJ5KB HAGER in PDF.

📄 4 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice HAGER WGCXT1RJ5KB - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Modular switch/disconnector
Brand Hager
Model WGCXT1RJ5KB
Dimensions (H x W x D) 90 x 18 x 65 mm (approx. per module)
Weight Approx. 80 g
Rated Voltage 230/400 V AC
Rated Current 16 A
Frequency 50/60 Hz
Function On/off switching, isolation
Mounting DIN rail mounting (EN 60715)
Degree of Protection IP20 (front panel)
Wire Connection Screw terminals, up to 2.5 mm²
Operating Temperature -25 °C to +60 °C
Storage Temperature -40 °C to +80 °C
Material Thermoplastic, self-extinguishing
Maintenance Wipe with dry cloth; no lubrication required
Safety Double insulation, shock protection
Spare Parts Contact Hager for replacement parts
Repairability Not user-serviceable; consult professional

Frequently Asked Questions - WGCXT1RJ5KB HAGER

How do I install the Hager WGCXT1RJ5KB?
Mount the device on a DIN rail (35 mm) in a distribution board. Ensure the power is off. Connect the phase and neutral wires to the appropriate terminals. Tighten screws securely.
What is the maximum current rating for this device?
The rated current is 16 A at 230/400 V AC.
Can I use this switch in outdoor applications?
No, the device has an IP20 protection rating, meaning it is only suitable for indoor use in dry environments.
How do I troubleshoot if the switch does not operate?
Check if the power supply is correct. Ensure the switch is not locked mechanically. Verify wire connections are tight. If the issue persists, contact a qualified electrician.
Is the WGCXT1RJ5KB compatible with smart home systems?
This model is a manual switch and does not include smart features. For smart integration, consider Hager's range of connected devices.
What tools are needed for installation?
Basic tools: screwdriver (flathead or Phillips), wire stripper, possibly a voltage tester. Use appropriate personal protective equipment.
Can I daisy-chain multiple switches?
Yes, but ensure the total current does not exceed the rating of the upstream circuit breaker. Follow local electrical codes.
How do I clean the device?
Disconnect power first. Wipe the exterior with a soft, dry cloth. Do not use water, solvents, or abrasive cleaners.
Where can I find the product manual?
The manual is available for free download on notice-facile.com in PDF format. You can also request a translated version via email.
What should I do if the switch feels warm?
A slight warmth is normal under load. If it is hot to the touch, check for overloading or loose connections. Consult an electrician if necessary.

User questions about WGCXT1RJ5KB HAGER

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Network Socket in PDF format for free! Find your manual WGCXT1RJ5KB - HAGER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. WGCXT1RJ5KB by HAGER.

USER MANUAL WGCXT1RJ5KB HAGER

Electrical equipment must only be installed and assembled by a qualified electrician in accordance with the relevant installation standards, regulations, directives and safety and accident prevention directives of the country.

Failure to comply with these installation instructions may result in damage to the device, fire or other hazards.

Function

The RJ45 outlets are used for data transmission in local area networks. The RJ11 outlets are designed for telephone and data applications. Each jack is equipped with a dust protection slider.

Correct use

  • For the flush-mounted installation in standard wall boxes (recommended wall box depth ≥ 35 mm).
  • Only suitable for use in indoor areas with no drip and no spray water.

Technical data

RJ45 outlets

Voltage proof (contact-to-contact): 1000 V DC or AC peak

Current rating: 0.75 A

Insulation resistance: ≥ 500 M at 100 V DC

Signal contact resistance: ≤ 20 mΩ

Type of connection: IDC terminals

Design: according to IEC 60603-7

Colour code A and B: according to TIA/EIA 568-B.2

RJ45 Cat.5e modules

Transmission bandwidth: max. 100 MHz

Conductor ∅ (solid): 0.51 ... 0.64 mm (AWG 24-22)

Cat.5e, unshielded (UTP): according to ISO/IEC 11801

RJ45 Cat.6 modules

Transmission bandwidth: max. 250 MHz

Conductor ∅ (solid): 0.51 ... 0.64 mm (AWG 24-22)

Cat.6, unshielded (UTP): according to ISO/IEC 11801, 2nd edition

RJ45 Cat.6A modules

Transmission bandwidth: max. 500 MHz

Conductor ∅ (solid): 0.41 ... 0.64 mm (AWG 26-22)

Cat.6A, unshielded (UTP): according to ISO/IEC 11801, edition 2.2

RJ11 outlet

Compliance: YD/T 577

Information for electricians

Installation and electrical connection

Preparing the device for installation

(for example "RJ11 + RJ45 outlet")

1A
Frame Notches

Hager Muse

Hager Inspire1B
Frame Cover plate Notches

  • Carefully loosen the frame on the notches with a flat-blade screwdriver. Lift up and remove the frame (1A/1B).
    Hager Inspire: Remove the cover plate also with a flat-blade screwdriver (1B).

Connecting the RJ45 data module

■ Remove the cover plate of the data module with a flat-blade screwdriver.

2A
UTP 30 mm

  • Strip 30 mm of cable jacket (2A).
    ■ Position and terminate first pair according to colour code A or B:

RJ45 pin assignment TIA/EIA 568B TIA/EIA 568A

HAGER WGCXT1RJ5KB - Connecting the RJ45 data module - 21 white/orange white/green
2 orange green
3 white/green white/orange
4 blue blue
5 white/blue white/blue
6 green orange
7 white/brown white/brown
8 brown brown

As with the first pair position and terminate each subsequent pair one at a time until termination is complete.
- Fix the cover plate back to the module.

Connecting the RJ11 telephone module

3A
10 mm

  • Strip 10 mm of cable jacket (3A).
    ■ Position first pair according to colour code:

RJ11 pin assignment
HAGER WGCXT1RJ5KB - Connecting the RJ11 telephone module - 2

natural_image Pure electrical circuit lines without any symbols

2 blue/white
3 white/blue
4 white/red
5 red/white

- Fix the cover plate back to the module.

HAGER WGCXT1RJ5KB - Connecting the RJ11 telephone module - 3

Checking of the installation:

A functional test of the installation should be made for each data or telephone outlet.

Installing the device into the wall box

(for example "RJ11 + RJ45 outlet")

4
HAGER WGCXT1RJ5KB - Installing the device into the wall box - 1

natural_image Technical diagram of a mechanical assembly with a bracket and tool, showing no text or symbols

■ After wiring, fix the device with the two screws attached into the wall box (4).

Assembling the covers

(for example "RJ11 + RJ45 outlet")

5A
5A Hager Muse Frame

Hager Muse

5B
5B Hager Inspire Cover plate Frame

Hager Inspire

■ Hager Muse: Snap the frame onto the device (5A).
■ Hager Inspire: Place the cover plate in the correct position and fix with frame (5B).

2-5gang frames are available for multiple combinations.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : HAGER

Model : WGCXT1RJ5KB

Category : Network Socket