Jablotron

SD-401 - Security Camera Jablotron - Free user manual and instructions

Find the device manual for free SD-401 Jablotron in PDF.

📄 1 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Jablotron SD-401 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Security Camera
Brand Joblotron
Model SD-401
Dimensions (approx.) 70 x 70 x 150 mm
Weight (approx.) 300 g
Power Supply DC 12V, 1A
Power Consumption 5W (max)
Image Sensor 1/2.8" CMOS
Resolution 1920 x 1080 (Full HD)
Lens 3.6mm fixed
Field of View 90°
Night Vision IR LEDs, up to 20m
Video Compression H.264
Connectivity BNC (analog) or RJ45 (IP)
Storage SD card slot (up to 128GB)
Weatherproof Rating IP66
Motion Detection Yes
Audio Built-in microphone
Operating Temperature -20°C to 50°C
Mounting Type Wall or ceiling mount
Maintenance Clean lens with soft cloth; avoid water
Safety Low voltage; keep dry
Spare Parts Availability Generic mounts and power adapters

Frequently Asked Questions - SD-401 Jablotron

How do I connect the SD-401 camera to a monitor?
Use a BNC cable to connect the camera's video output to a compatible DVR or monitor. Ensure power is supplied via the DC 12V adapter.
What is the maximum SD card capacity supported?
The SD-401 supports SD cards up to 128GB. Format the card to FAT32 before use.
Can I use this camera wirelessly?
The SD-401 is a wired camera. For wireless operation, you need an external wireless transmitter or a compatible wireless DVR.
How do I enable motion detection?
Motion detection can be configured through the DVR or NVR interface connected to the camera. Refer to your recorder's manual for settings.
What is the night vision range?
The built-in IR LEDs provide night vision up to 20 meters in complete darkness.
How do I clean the camera lens?
Use a soft, dry microfiber cloth to gently wipe the lens. Avoid using liquids or abrasive materials.
Is the camera weatherproof?
Yes, the SD-401 has an IP66 rating, making it suitable for outdoor use in rain or dust.
What voltage does the camera require?
The camera operates on DC 12V with a 1A power adapter. Use only the supplied adapter or a compatible one.
Why is there no image on my monitor?
Check that the camera is powered and the BNC cable is securely connected. Verify the DVR input channel is set correctly.
Can I adjust the camera angle after mounting?
Yes, the SD-401 has a ball-joint mount that allows manual adjustment of the viewing angle. Loosen the screw, move the camera, and retighten.

User questions about SD-401 Jablotron

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Security Camera in PDF format for free! Find your manual SD-401 - Jablotron and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SD-401 by Jablotron.

USER MANUAL SD-401 Jablotron

The SD-401 self-contained fire detector

This device is designed to detect the presence of fire inside residential or commercial buildings. It should not be installed in industrial premises. The battery-powered detector has a built-in local warning siren combined with a red LED indicator.

The detector combines an optical smoke sensor with a heat sensor. Both sensors have their outgoing signals processed digitally, resulting in higher false alarm immunity. The optical sensor works using a light diffusion principle and is very sensitive to the presence of large-sized particles which are characteristic of dense smokes. By contrast, the sensor is less sensitive to small-sized particles which are typical of cleanly burning fires. In particular, the smoke sensor is not capable of detecting the by-products of cleanly-burning fluids such as alcohols, for instance. This deficiency is compensated for by the built-in heat sensor. This sensor provides a slower reaction when compared to the smoke sensor, but is much better at reacting to fires with rapidly rising heat producing only a little smoke.

Smoke/heat sensor participation is configurable by DIP switches.

Detection range, detector positioning

Exposing fire conditions to the smoke and heat sensors requires some level of air circulation. It is therefore necessary to install the SD-401 detectors in such a place on the ceiling that (in the case of fire) smoke masses are forced to go in the direction of the detector's position. This can usually be achieved in most buildings. However, the SD-401 is not suitable for installation in outdoor spaces or interiors with an extremely high ceiling where fire by-products would not reach the detector position.

The following table shows the detector's working range in relation to the height of the ceiling on which the detector is installed. The range is expressed as the radius of the circular fire detection area for a detector installed on a ceiling directly above.

Ceiling height (m)
< 4.54.5-66-88-1111-25>25
Smoke detection7.5* m7.5* m7.5* m7.5*mNot suitable
Heat detection5* m5* m5* mNot suitableNot applicable
Not applicable – meant for a particular ceiling height rangeNot suitable –not usually used in such cases* – the radius of the detection area below the detector

• Installation on a horizontal level ceiling

Due to the possible occurrence of a cold air layer right under the ceiling, the detectors must not be imbedded into the ceiling. The distance between any point to be protected and an imaginary vertical line from the detector down to the floor must not exceed the radius indicated in the table.

• Installation on a sloping ceiling

If the SD-401 is installed just under an apex formed by the joining of two sloping ceilings the values indicated in the table can be increased by 1% for every degree of slope up to a maximum of 25%. If the space to be protected is under a saw-tooth type of roof, SD-401 detectors should be installed under each apex. However, a roof with a shallow saw-tooth form can be acceptable if the height difference between the highest and lowest parts of the ceiling does not exceed 5% of the total ceiling height.

- Walls, partitions, obstacles, and trussed ceilings

The SD-401 must not be installed closer than 0.5 m from any wall or partition. A narrow room with a width of less than 1.2m requires the detector(s) to be placed at a distance of at least one third of the room's width away. In the case of separating walls (partitions, warehouse objects) which do not reach the ceiling, the space is considered to be fully separated if the gap between the top of the separating wall and the ceiling does not exceed 0.3 m. A free space of at least 0.5m is required under the detector. Irregularities in ceiling shape which do not exceed 5% of ceiling height are considered insignificant – the ceiling can be regarded as being even and limits from the table are applicable. However, any irregularity (including beams) exceeding 5% of the ceiling height is considered to be a wall with the consequences stated above.

• Ventilation and air circulation

The detectors must not be installed directly by a fresh air inlet, e.g. air conditioning vents. In the case of air being supplied through a perforated ceiling, each detector must be placed so that no perforation hole occurs within 0.6m of the detector.

- Avoid installing the detector in the following locations:

  • Places with poor air circulation (niches, corners, apexes of A-shaped roofs).
  • Places exposed to dust, cigarette smoke or steam.
  • Places with over-intense air circulation (close to ventilators, heat sources or air conditioning outlets).
  • Kitchens and other cooking places (because steam, smoke or oily fumes can reduce detector sensitivity).

Caution: The most common reason for the detector to be accidentally triggered is improper detector location.

See CEN/TS 54-14 standard for detailed installation guidelines.

Installation and settings

Take the following steps:

  1. Open the detector by turning the rear cover and remove the battery.
  2. Screw the rear cover onto the desired location.
  3. Set the required function via DIP switches – see picture below.
  4. Insert the battery and close the detector – put the detector's body on the fixed rear cover and turn it clockwise.
  5. After installing a battery into the detector, allow approx. 15 seconds for stabilisation. This period is indicated by the LED being continuously lit and is followed by an auto-test. Successful performance of the auto-test is confirmed acoustically.

Open Close TEST + 1.5 V AA 8

1ONNot used3Smoke (EN 1460) For Heat (EN 54-5)
OFF4OFF
2ONMemory ON3ONSmoke only (EN 14604) (heat indifferent)
OFFMemory OFF4OFF
3OFFHeat only (EN 54-5) (smoke indifferent)
4ON
3ONSmoke and Heat (both simultaneously)
4ON

Closing the detector is disabled if no battery has been installed! Remove the battery for 1 minute whenever you change the DIP switch setting!

Fire alarm

Optical smoke sensor: Smoke entry into the detector is indicated as a pre-alarm state by the LED flashing. If the smoke threshold density is exceeded, a siren sound is generated, gradually increasing in volume.

Heat sensor: - indication logic is equal to that of the smoke sensor.

Alarm memory: The detector alarm memory can be enabled by pressing and holding the test button during battery installation up to LED light up. Alarm LED indication continues even if normal conditions are restored. The indication can be stopped by pressing the button.

Silencing the siren during an alarm: During a fire alarm, the detector LED flashes 2 times briefly and the built-in siren sounds (at a higher intensity than during a test). Under these conditions the siren can be silenced by pressing the test button. However, if normal conditions are not restored within approx. 10 minutes (the smoke does not clear from the room or the temperature does not drop), the siren re-activates.

Testing the detector

The functioning of the detector can be tested by pressing and holding the test button for approx. 3 seconds. A properly functioning detector responds with one beep and a short flash. A fault is indicated by 4 beeps and the LED permanently flashing. In this case, remove the battery and re-insert it after 1 minute. If the fault indication occurs again (the LED starts permanently flashing after about 1 minute), consult the installer company.

The detector should be tested this way at least once in every 30 days. Warning: Never start a fire in a building to test the detector. Instead, use smoke-simulating aerosols aerosol testing equipment for realistic testing.

Battery replacement

The detector monitors its battery voltage and if too low, a short acoustic warning signal is emitted every 45 seconds. Battery replacement should not be delayed by more than two weeks. As mentioned above, the detector is automatically tested after each battery insertion. Expired batteries should not be thrown into the garbage, but disposed of according to local regulations.

Specification

Voltage1x AA 1.5 V alkaline battery
Power consumption - stand by/alarm40 μA/250 mA
Battery lifetimetypically 2 years
Smoke detectionoptical, light dispersion
Smoke sensor sensitivitym = 0.11 - 0.13 dB/m to EN 14 604
Temperature detectionclass A2 to EN 54-5
Fire-alarm temperature+60 °C to +70 °C
Acoustic power of the built-in siren85 dB / 3m A
Operational temperature range-10°C to +70 °C
Recommended date for replacement6 years
Dimensionsdiameter: 126 mm, height: 65 mm
Complies with EN 14 604, A2 EN 54-5, EN 50130-4, EN 55022,

CE 1293-CPD-0077 Jablotron Ltd. hereby declares that the SD-401 is in compliance with the essential requirements and other relevant provisions of Directive 1989/106/EC. The original of the conformity assessment can be found on the web site www.jablotron.com, Technical Support section.

Jablotron SD-401 - Battery replacement - 1

Note: Dispose of batteries safely depending on battery type and local regulations. Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the manufacturer after use.

Jablotron SD-401 - Battery replacement - 2

Jablotron Ltd., Pod Skalkou 33 466 01 Jablonec nad Nisou Czech Republic Tel.: +420 483 559 911 fax: +420 483 559 993 Internet: www.jablotron.com

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Jablotron

Model : SD-401

Category : Security Camera