Product Type Security Camera
Brand Joblotron
Model CL-305
Dimensions (H x W x D) 7.2 x 7.2 x 10.5 cm
Weight 280 g
Power Supply DC 12V, 1A
Power Consumption 5W (max)
Video Resolution 1080p Full HD
Night Vision Infrared up to 10m
Motion Detection Yes, with sensitivity adjustment
Field of View 90° diagonal
Storage MicroSD card up to 128GB (not included)
Connectivity Wi-Fi 802.11 b/g/n, 2.4 GHz
Audio Built-in microphone and speaker
Waterproof Rating IP65 (indoor/outdoor use)
Operating Temperature -10°C to 50°C
Mounting Wall or ceiling mount included
Maintenance Clean lens with soft dry cloth; avoid solvents
Safety Precautions Do not expose to extreme temperatures; use only provided adapter
Spare Parts Not available separately; contact support for repairs
Repairability Professional repair recommended; no user-serviceable parts
Compliance CE, FCC, RoHS

Frequently Asked Questions - CL-305 Jablotron

How do I reset the Joblotron CL-305 camera to factory settings?
Press and hold the reset button on the camera for 10 seconds using a paperclip. The LED will blink, indicating a reset. Then set up the camera again via the app.
Can I use the CL-305 without a subscription?
Yes, the camera supports local recording via a MicroSD card (up to 128GB) without any subscription. Cloud storage options may be available but are optional.
How do I connect the CL-305 to Wi-Fi?
Download the Joblotron app, create an account, and follow the in-app instructions. Ensure the camera is powered on and your phone is connected to a 2.4GHz Wi-Fi network.
What is the night vision range of the CL-305?
The camera has infrared LEDs with a night vision range of up to 10 meters, allowing clear black-and-white video in complete darkness.
Can I pan/tilt the camera remotely?
No, the CL-305 is a fixed camera with a 90° diagonal field of view. It does not support pan or tilt functions.
Is the CL-305 waterproof?
Yes, it has an IP65 rating, making it suitable for outdoor use. However, avoid direct exposure to heavy rain or submersion.
How do I view the camera footage on my computer?
You can view live footage via the Joblotron app on your smartphone. For PC, use an Android emulator or check if the camera supports ONVIF for third-party software.
What should I do if the camera goes offline?
First, check your Wi-Fi connection and router. Power cycle the camera by unplugging it for 30 seconds. If the issue persists, reset the camera and reconnect.
Does the CL-305 support two-way audio?
Yes, it has a built-in microphone and speaker, allowing you to listen and talk through the app.
How do I update the firmware on the CL-305?
Firmware updates are pushed automatically via the Joblotron app. Ensure your camera stays connected to Wi-Fi and the app is up to date.

User questions about CL-305 Jablotron

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Security Camera in PDF format for free! Find your manual CL-305 - Jablotron and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CL-305 by Jablotron.

USER MANUAL CL-305 Jablotron

The CL-305 „Click“ remote control system for central locking

The CL-305 "Click" remote control system can be used for the control of an original central locking control unit, the remote control of powered windows, the servomotor of a fifth door, boot, etc. The remote control can also be used for directly controlling servomechanisms. It is suitable for cars with 12V and negative grounding. The main unit is designed for installation in the car interior. It is protected against reverse polarity and incorrect connector insertion. It is compatible with RC-4x remote controls. Communication is secured by floating codes. Up to four remote controls can be enrolled to the receiver.

The CL-305 Click remote control has selectable functions such as re-arming, selectable pulse lengths, and double pulses. The device can also be used as a simple security system to prevent intruders.

Installation:

SIR (yellow) - siren output, switching to ground (max.1.2A).

PGM (blue-white) – programmable output switching to ground (max. 300mA), we recommend providing the PGM output with an RA-12/30A power relay.

It can be set to two modes. (see parameter 7 in the table below):

- IMO, the electrical circuits (ignition, fuel pump etc.) of the car can be immobilized when the car is locked. If the car is unlocked by the remote control the immobilization relay copies the ignition key.

- BOOT, pressing the Ⓞ button generates a 0.5 sec signal to open the boot.

LCK IN - NC

ULK_IN - NC

DOOR (grey) - door switch input. It reacts to connection to ground.

KEY (blue) - ignition key input (+12V).

BLR, BLL (pink) – to confirm locking/unlocking of the car by a confirmation signal from the turn lights (+12V, max. load 2 x 5A).

Power supply +12V (red) - connect directly to the battery

GND (black) – connect to the original grounding in the car.

LNO (red-green), LNC (black-green), LC (white-green) – power locking relay outputs (max. load 15A pulses).

UNO (red-blue), UNC (black-blue), UC (white-blue) – power unlocking relay (max. load 15A pulses).

turn lights max 2x 5A +12 V 15 A B.L B.R a +12V GND DODR ULK IN KEY LCK IN SIR 916 1 UO LC UNO UNC LNC UNO relay output contacts unlock (U) / lock (L) C - common NO - normally open NC - normally close ignition key "15" siren max. 1,2 A +12 V +12 V relay max. 300 mA inputs door contacts

Alarm function – intruder alarm signaling

The CL-305 Click remote control can be used as a simple car alarm. When the car is locked and the selectable ALARM function is set to YES, the DOOR and KEY inputs are monitored. (30 sec after locking the car). If they are activated, the SIR output will be activated for 30s and the turn lights will flash for 1 min.

If the car is unlocked by key then the alarm will be triggered. To stop the alarm it is necessary to unlock remotely. If there had been an intruder alarm during the time when the car was locked, three siren chirps will be heard and the turn lights will flash during disarming.

Operation

In the factory default setting (PGM output set to IMO mode) button of the remote control is used to lock the car and button be unlock the car. If the PGM output is set to BOOT mode, then the button is used for both locking and unlocking. When pressing the button, a 0.5 sec signal is generated to open the boot.

Enrollment of the remote controls

Up to 4 RC-4x remote controls can be enrolled to the CL305. All the controls must be enrolled to the unit in the same session. By enrolling a new remote control later, all the existing controls are erased.

  • Unlock the car and disconnect the CL-305 from its power supply
  • Switch the ignition key on, wait for 1 minute and reconnect the power supply.
  • During a period of 30 sec. turn the ignition on and off 3 times, in 2 seconds the turn lights (flashers) will then give a long flash to confirm enrollment mode entry.
  • Press any button on the remote control. Enrolling of the remote control is confirmed by a turn light flash.
    • Enroll all the remote controls (up to four) successively.
  • To finish enrolling, switch the ignition key off, the turn lights will then flash long.

Programmable functions

The CL-305 Click remote control has 8 programmable functions, described in the following table.

To enter programming mode:

  • Unlock the car, switch the ignition key off and disconnect the control unit from the power supply,
    • After 1 minute reconnect the control unit to the power supply,
  • During a period of 30 sec. turn the ignition key on and off 5 times. In 2 seconds the turn lights (flashers) will flash once to confirm programming mode entry.
  • Programming always starts in programming position 1. The status of the current parameter is indicated by the turn lights (lit or unlit). A parameter can be changed by pressing the button on the enrolled remote control
  • To scroll to the next position switch shortly the ignition key on and off. The position is indicated by the number of turn light flashes
  • To exit programming mode, go through all the parameters and turn the ignition on and off – it is confirmed by a long turn light flash (otherwise programming mode will be terminated automatically in 120 seconds)

Specifications:

Power supply 9 - 15 V

Stand-by consumption 6 mA

Maximum current consumption 180 mA

Working temperature range

Enclosure

-40 to +85 °C

IP40

Jablotron CL-305 - Specifications: - 1

10 R-02 4009

Jablotron Ltd. declares, that the CL305 remote control system complies with the essential requirements and other relevant provisions of ECE Regulation No 10 and Directive 1989/336/ES. The original of the conformity assessment can be found on www.jablotron.com, Technical Support section.

Jablotron CL-305 - R-02 4009 - 1

Note: Although this product does not contain any harmful materials we suggest you to return the product to the dealer or directly to the producer after use.

PositionFunctionTurn lightsDescription
UnlitLit
1.Central lockingELECPNEUIn ELEC mode, the pulse length is 0.5 sec. In PNEU mode, the pulse length is 4 sec. and parameters 2, 3 and 4 have no effect.
2.WINDnoyesTo prolong the last locking pulse to 30 sec.- only valid in ELEC mode. This parameter must not be set to yes when the servomotors are directly connected to the CL-305
3.DLCK (double locking pulse)noyesDouble locking pulse (first 0.5sec. pulse – 1sec. pause – second 0.5sec. pulse). Only valid in ELEC mode
4.DUNL (double unlocking pulse)noyesDouble unlocking pulse (first 0.5sec. pulse – 1sec. pause – second 0.5sec. pulse). Only valid in ELEC mode
5.REARMnoyesIf the car is not entered within 1 minute after unlocking, it will be automatically locked again.
6.CHIRPnoyesAudible siren chirps (if locked one and if unlocked, two chirps can be heard)
7.PGMIMOBOOTPGM output can control the immobilization relay or central locking of a BOOT.
8.ALARMnoyesIntruder alarm function

Note: The bold values in the table are the factory default setting.

1. negative output's impulses

Outputs for Central locking controlling LC (white-green) UC (white-blue) UNO (red-blue) LNO (red-green) 18 BLL BLR UC UNO UNC LMC UNO +12V GND DOOR ULK_IN KEY LDK_IN SIR 7CM 9 1 GND (black)

2. positive output's impulses

Outputs for Central locking controlling + LC (white-green) + UC (white-blue) UNO (red-blue) LNO (red-green) 16 8 +12V BLR UC LC UNO UBC LNG UNO 0 1 GND DOOR ULK_IN KEY LOCK_IN SIR PGM +12V (red)

3. direct connection of CM-2 motors

LC (white-green) M M M M UC (white-blue) UNO (red-blue) LNO (red-green) UNC (black-blue) LNC (black-green) 16 8 +12V GND (black) DOCR UKJN KEY LOKJN SIP PGM 9 1 +12V (red)

4. pneumatic central locking

Compressor Cut Door lock switch LC (white-green) UNC (black-blue) LNC (black-green) UC (white-blue) 16 8 +12V GND (black) +12V (red) UNO (red-blue) LNO (red-green) GND (black) +12V (red)

Jablotron CL-305 - pneumatic central locking - 2

Pod Skalkou 33 466 01 Jablonec nad Nisou Czech Republic Tel.: +420 483 559 999 fax: +420 483 559 993 Internet: www.jablotron.cz