Product Type Electric Mill
Brand XU1
Model XAG-401U
Dimensions (L x W x H) 12 x 10 x 22 cm
Weight 1.1 kg
Power Source AC 220-240V, 50/60Hz
Rated Power 150 W
Capacity (Coffee Beans) 70 g
Grinding Settings Adjustable from fine to coarse (12 levels)
Bowl Material Stainless steel
Blade Material Stainless steel
Housing Material ABS plastic
Operation One-touch pulse grinding
Safety Features Overheat protection, non-slip base
Cleaning Removable stainless steel bowl, wipe clean
Spare Parts Available Replacement blades and bowl sold separately
Repairability Repair service via authorized center
Certifications CE, RoHS
Package Contents Mill, grinding bowl, lid, user manual
Manual Language English (EN)

Frequently Asked Questions - XAG-401U XU1

How do I clean the XU1 XAG-401U mill?
Unplug the mill and wipe the stainless steel bowl with a damp cloth. Do not immerse in water. The bowl is removable for easy cleaning.
Can I grind wet ingredients with this mill?
No, this mill is designed for dry beans, spices, and grains only. Wet ingredients may damage the motor.
What is the maximum grinding time?
Do not operate continuously for more than 30 seconds. Let the mill cool down for 2 minutes between uses.
How do I adjust the grind size?
Turn the grind size selector on the lid to your desired setting: fine for espresso, coarse for French press.
Is the blade replaceable?
Yes, replacement blades are available from XU1 authorized retailers. Contact support for part numbers.
Why does the mill stop during operation?
The mill has overheat protection. If it stops, let it cool for 10 minutes before restarting. Ensure the bowl is not overloaded.
Can I grind nuts in this mill?
Yes, but only dry nuts like almonds or peanuts. Grind in short bursts and monitor to avoid overheating.
What do the different grind settings mean?
Setting 1 is finest for espresso, setting 6 is medium for drip coffee, and setting 12 is coarse for French press.
How do I replace the bowl?
Turn the bowl counterclockwise to unlock and lift off. Place the new bowl and turn clockwise to lock into place.
Is the mill safe for continuous use?
No, the mill is designed for intermittent use. Follow the duty cycle: max 30 seconds on, 2 minutes off.

User questions about XAG-401U XU1

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Mill in PDF format for free! Find your manual XAG-401U - XU1 and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. XAG-401U by XU1.

USER MANUAL XAG-401U XU1

Please note that the following parts of this product are subject to normal or natural wear and that the following parts are therefore also required for use as consumables.

Category Example
Wear parts* Carbon brushes
Consumables* Cutting wheels, grinding wheels
Missing parts

* Not necessarily included in the scope of delivery!

The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of the iSC GmbH.

Subject to technical changes

Declaration of conformity

ISC GmbH · Eschenstraße 6 · D-94405 Landau/Isar
explains the following conformity according to EU directives and norms for the following product
Angle Grinder XAG-401U (XU1)
☐2014/29/EU☒2006/42/EC
☐2005/32/EC_2009/125/EC☐Annex IVNoof ed Body:Noof ed Body No.:Reg. No.:
☐2014/35/EU☐2000/14/EC_2005/88/EC
☐2006/28/EC
☒2014/30/EU☐Annex VAnnex VINoise: measured Imax = dB (A): guaranteed Imin = dB (A) P × W ; ISD = c mNoof ed Body:
☐2014/32/EU
☐2014/53/EC
☐2014/68/EU
☐90/396/EC_2009/142/EC☐2004/26/EC
☐89/686/EC_96/58/ECEmission No.:
☒2011/65/EU
Standard references: EN 60745-1; EN 60745-2-3;EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3
Landau/Isar, dien 26.01.2017
First CE: 17 Archive-Pile/Record: NAPR015372Art.-No.: 44.307.84 L-No.: 11016Subject to change without notice Wasenweg 22, D-94405 Landau/Isar

XU1 XAG-401U - Declaration of conformity - 1

XAG-401U

GB Additional operating & safety instructions Angle Grinder

Line drawing of a power tool with a mounted angle grinder (no text or symbols)

XU1 XAG-401U - Declaration of conformity - 3

XU1 XAG-401U - Declaration of conformity - 4

Danger! - Read the operating instructions to reduce the risk of inquiry

XU1 XAG-401U - Declaration of conformity - 5

Caution! Wear ear-muffs. The impact of noise can cause damage to hearing.

XU1 XAG-401U - Declaration of conformity - 6

Caution! Wear a breathing mask. Dust which is injurious to health can be generated when working on wood and other materials. Never use the device to work on any materials containing asbestos!

XU1 XAG-401U - Declaration of conformity - 7

Caution! Wear safety goggles. Sparks generated during working or splinters, chips and dust emitted by the device can cause loss of sight.

XU1 XAG-401U - Declaration of conformity - 8

XU1 XAG-401U - Declaration of conformity - 9

This safety guard is designed for cutting and grinding/sanding. (not included in items supplied)

Items supplied

Please check that the article is complete as specified in the scope of delivery. If parts are missing, please contact our service center or the sales outlet where you made your purchase at the latest within 5 working days after purchasing the product and upon presentation of a valid bill of purchase. Also, refer to the warranty table in the service information at the end of the operating instructions.

- Open the packaging and take out the equipment with care

- Remove the packaging material and any packaging and/or transportation braces (if available).

- Check to see if all items are supplied. - Inspect the equipment and accessories for transport damage.

• If possible, please keep the packaging until the end of the guarantee period.

Danger!

The equipment and packaging material are not toys. Do not let children play with plastic bags, foils or small parts. There is a danger of swallowing or suffocating!

Proper use

The angle grinder is designed for grinding metal and stone when using the appropriate grinding wheel and guard. Warning! To cut metal and stone the grinder/sa der may only be used when the guard (available as an accessory) is mounted.

The equipment is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user/operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this.

Please note that our equipment has not been designed for use in commercial, trade or industrial applications. Our warranty will be voided if the machine is used in commercial, trade or industrial businesses or for equivalent purposes.

Technical data

Mains voltage: 230 V - 50 Hz

Power input: 500 W

fding speed: 12,000/min Max. wheel diameter: 115 mm

Grinding wheel: 115 x 22.2 x 6 mm

Cutting wheel (not included): ..115 x 22.2 x 3 mm

Mounting spindle thread. M 14 Protection class: II/回

Danger!

Sound and vibration

Sound and vibration values were measured in

accordance with EN 60745.

LpA sound pressure level ....82 dB(A)

KpA uncertainty 3 dB

LWA sound power level 93 dB(A)

Wear ear-muffs.

The impact of noise can cause damage to hearing.

Total vibration values (vector sum of three direc-

tions) determined in accordance with EN 60745.

Surface sanding/grinding

Vibration emission value aBAG = 4.81 m/s2

K uncertainty = 1.5 m/s 4

The specified vibration value was established in accordance with a standardized testing method. It may change according to how the electric equipment is used and may exceed the specified value in exceptional circumstances.

The specified vibration value can be used to compare the equipment with other electric power tools.

The specified vibration value can be used for initial assessment of a harmful effect.

Keep the noise emissions and vibrations to a

minimum.

• Only use appliances which are in perfect wor-

king order.

• Service and clean the appliance regularly.

• Adapt your working style to suit the appliance. • Do not overload the appliance.

• Have the appliance serviced whenever

necessary

• Switch the appliance off when it is not in use.

• Wear protective gloves.

Caution!

Residual risks

Even if you use this electric power tool in ac-

cordance with instructions, certain residual

risks cannot be rules out. The following ha-

zards may arise in connection with the equip-

ment's construction and layout:

  1. Lung damage if no suitable protective dust

mask is used

  1. Damage to hearing if no suitable ear protecti-

on is used.

  1. Health damage caused by hand-arm vibra-

tions if the equipment is used over a pro-

longed period or is not properly guided and

maintained.

XU1 XAG-401U - Residual risks - 1

For EU countries only

Never place any electric power tools in your

household refuse.

To comply with European Directive 2012/19/EC

concerning old electric and electronic equipment

and its implementation in national laws, old elec-

tric power tools have to be separated from other

waste and disposed of in an environment-friendly

fashion, e.g. by taking to a recycling depot.

Recycling alternative to the return request:

As an alternative to returning the equipment to

the manufacturer, the owner of the electrical

equipment must make sure that the equipment

is properly disposed of if he no longer wants to

keep the equipment. The old equipment can be

returned to a suitable collection point that will

dispose of the equipment in accordance with the

national recycling and waste disposal regulations

This does not apply to any accessories or aids

without electrical components supplied with the

old equipment.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : XU1

Model : XAG-401U

Category : Mill