TFA 16A - Thermostats

16A - Thermostats TFA - Free user manual and instructions

Find the device manual for free 16A TFA in PDF.

📄 4 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice TFA 16A - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Thermostat
Brand TFA
Model 16A
Dimensions (approx.) 80 x 80 x 25 mm
Weight (approx.) 150 g
Power Supply 230 V AC, 50 Hz
Max Load 16 A (resistive)
Temperature Range 5-35 °C
Accuracy ±1 °C
Display Type LCD digital display
Control Type Mechanical or electronic (model dependant)
Functions Temperature control, frost protection, overheat protection
Mounting Wall-mounted (flush or surface)
Protection Rating IP20
Certification CE, RoHS
Maintenance Clean with dry cloth; avoid liquids
Safety Features Overheating protection, child lock (if applicable)
Spare Parts Contact TFA support for spare parts
Repairability Service by qualified electrician recommended
General Information Thermostat for home heating control; compatible with resistive loads up to 16A

Frequently Asked Questions - 16A TFA

How do I set the desired temperature on the TFA 16A thermostat?
Use the up/down buttons on the thermostat to adjust the set temperature. The display will show the current setpoint.
What is the maximum load the thermostat can handle?
The TFA 16A thermostat can handle a maximum resistive load of 16 amperes. Ensure the connected load does not exceed this rating.
Can I use this thermostat with underfloor heating?
Yes, if the underfloor heating system is resistive and does not exceed 16A. However, for specific compatibility, consult the manual.
How do I activate frost protection mode?
Frost protection is usually activated by setting the thermostat to a low temperature (e.g., 5-7°C). The display may show a snowflake icon. Refer to your manual.
What does the 'Err' or 'E' code mean on the display?
An error code indicates a sensor fault or internal error. Try resetting the thermostat by turning the power off for a few minutes. If the error persists, contact TFA support.
Is the TFA 16A thermostat suitable for electric heaters?
Yes, it is suitable for resistive electric heaters such as baseboard heaters, fan heaters, or oil-filled radiators up to 16A.
How do I clean the thermostat?
Use a soft, dry cloth to clean the exterior. Do not use water, solvents, or abrasive cleaners. Avoid getting moisture inside the unit.
Can I install the thermostat myself?
Installation should be done by a qualified electrician to ensure correct wiring and compliance with local regulations.
What is the temperature control range of this model?
The TFA 16A thermostat has a temperature control range of 5°C to 35°C.
Where can I find the user manual for the TFA 16A?
You can download the free PDF manual from notice-facile.com or the TFA website. Enter the model 16A in the search bar.

User questions about 16A TFA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermostats in PDF format for free! Find your manual 16A - TFA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 16A by TFA.

USER MANUAL 16A TFA

The ET01 Thermo-Timer is a very versatile product that can control both temperature and timer independently and in cohesion. Its sophisticated internal program allows users many different combinations for various applications. The external water proof temperature probe with cable allows temperature measurement in remote environment. Following is the description of the operation of the ET01.

LCD display

8:00:8.8 AM PM ON INT C EX8 D E G F

A) Thermo-Timer in Timer mode icon
B) Thermo-Timer in ON state
C) Thermo-Timer in OFF state
D) Thermo-Timer in Temperature mode icon
E) Timer/Temperature control pair number
F) Timer/Temperature control disable
G) C/F icon

1. Power On and normal Display Modes

When an AAA battery is first inserted, all LCD display segments will be on for a brief period then the display jumps to show clock time and an icon INT (means control is interrupted or disabled). By pressing the MODE key once, the display can also be diverted to show the temperature value which is the temperature measured by the probe. The display can therefore be toggled between time and temperature by pressing the MODE key.

2. Clock Set

In the clock mode, press the SET key once, an icon C will shown blinking. This is the set clock mode. Hours and minutes values can now be entered by pressing the keys h/▲ and m/▼. Press SET key once to return to normal clock display.

3. Modes of Operation

There are in total three control modes of operation in ET01 selectable by the user to fit his application requirement.

  • Thermo mode
  • Timer mode
  • Thermo-Timer mode

Each mode is independent of the other and at each time only one mode can be in operation. Activate one mode means automatically disabling the other previously active mode.

Mode 1 – Temperature control mode – symbol is ( ■ )

To enter this mode, in normal clock or temperature display mode, press SET key once to see the flag C blinking. Now press the MODE key once to see the display changes to set temperature value mode which shows 18 °C as the default value. A thermometer flag is shown blinking denoting the user he is in temperature set mode. The temperature value can now be changed up or down by the h/▲ or the m/▼ keys. The settable range is 40°C to 0°C. After the desired value is set, press SET key once to leave the temperature set mode and returns to normal temperature display mode. The thermometer flag is now showing steadily. If the control temperature set value is higher than the temperature measured by the probe, the flag ON will be shown to inform the control output is now active. Otherwise the INT flag is maintained. The temperature control activity can be temporarily suspended by first entering the set temperature mode, then press the Manual Override key once, a cross X flag will appear to inform the temperature control action is now suspended.

Mode 2 - Timer Control Mode – symbol is ( )

To enter this mode, in normal clock or temperature mode, press SET key once to see the flag C blinking. Now press the MODE key twice to enter the Timer Control Mode. The timer symbol ⏻ is shown blinking together with the value of the first ON timer value which is shown in the following diagram if no value has been entered before:

Diagram showing symbols and labels including 'ON' and geometric shapes with squares and circles

Use keys h/▲ and m/▼ to enter the hours and minutes of the ON time for the first timer pair. Press SET once to enter the value of OFF (INT) time for the first pair. In like manner the ON time and OFF time of the three timer pairs can be entered.

Each ON and OFF times can be suspended by using the Manual Override key during time setting. A symbol is shown to denote this condition.

The control output is activated each time the real clock time matches the set timer time. This means three time periods can be controlled for ON and OFF.

Mode 3 - Thermo-Timer mode - symbols is ( )

This is a combined operation mode of mode 1 and mode 2. In this mode three time pairs with three different temperature values can be set so that three temperatures in three periods of time can be controlled.

To enter this mode, press SET key once in normal mode to see the blinking C. Now press the MODE key three times to see the flags and . The timer flag is blinking to notify that the timer value can be set. After setting the ON time, press SET key to enter temperature value set where the flag is blinking. Enter the desired temperature value then press SET key again to set the OFF time. In like manner all three pairs of timers and temperature values can be set. All values can be suspended by using the Manual Override key as before.

Manual Override Function

During operation, the output condition of the ET01 can be altered by press the Manual Override key once, if the flag ON is shown then it will change to INT and blinking. If the INT is on, then it will switch to ON and blinking.

Notes of Importance:

  1. The product can be completely reset by press down SET and MODE together and release. It will return to the POWER ON condition and all set values will be lost.
  2. If the display seems dim then it is time to change the battery. All set values will be lost after battery change and needs to be re-entered
  3. The temperature probe is protected by a metal shield and plastic cover. Make sure they are not damaged so that water proofing is not longer possible. Store the probe and cable inside the compartment at the bottom of the ET01 if not used.
  4. Maximum probe length is 1 meter and control range is from 20° C to 40° C.

Victorsure Limited - October/2003