MD22S - Filtre magnétique pour chauffage central Salus - Free user manual and instructions
Find the device manual for free MD22S Salus in PDF.
| Product Type | Programmable Thermostat |
| Brand | Salus |
| Model | MD22S |
| Dimensions (H x W x D) | Approx. 120 x 80 x 30 mm |
| Weight | Approx. 150 g including batteries |
| Power Supply | 2x AAA alkaline batteries (included) |
| Battery Life | Approx. 1 year under normal use |
| Display Type | LCD screen with backlight |
| Temperature Control Range | 5°C to 35°C (41°F to 95°F) |
| Accuracy | ±0.5°C |
| Programming | 7-day, 4 time periods per day (Wake, Leave, Return, Sleep) |
| Compatibility | Gas, oil, electric heating systems; most 24V systems |
| Wireless Connectivity | None (standalone model) |
| Installation | Wall-mounted, requires wiring for heating control |
| Safety Features | Frost protection mode, low battery indicator |
| Maintenance | Clean with soft dry cloth; replace batteries annually |
| Spare Parts | Batteries (AAA), mounting screws |
| Repairability | Not user-serviceable; contact authorized service center |
| Operating Environment | Indoor use only, temperature 0°C to 40°C, humidity ≤90% non-condensing |
| Certifications | CE, RoHS |
| Included Accessories | Mounting plate, screws, wall plugs, quick start guide |
Frequently Asked Questions - MD22S Salus
User questions about MD22S Salus
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Filtre magnétique pour chauffage central in PDF format for free! Find your manual MD22S - Salus and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MD22S by Salus.
USER MANUAL MD22S Salus

The following instructions are designed to help the engineer to install and maintain the Magnetic Filter safely and efficiently and should be followed and adhered to at all times. Make sure there is a water-filling pipeline behind the filter. During maintenance, check whether the lid seals are worn or damaged. The best practice is to replace the lid seal at each repair.
1. INTRODUCTION
The Magnetic Filter is specially designed for central heating systems. It can remove almost all the harmful black suspended iron oxide particles accumulated in the central heating system and protect the complete central heating system.
2. MOUNTING RECOMMENDATIONS
The filter can be installed in a variety of ways, for example: be installed at any locationonthemainpipeline. However, it is recommended to be installed after the last radiator and before the boiler on the primary return pipework for maximum protection and efficiency.
Note: It is important to have adequate access for maintenance and servicing when determining a suitable installation location.
Recommended installation location

flowchart
graph TD
A["Boiler"] --> B["Valve"]
B --> C{Checkmark}
C -->|Yes| D["Return"]
C -->|No| E["Filter"]
E --> F["Bar/Bar Block"]
F --> B
style A fill:#f9f,stroke:#333
style B fill:#ccf,stroke:#333
style C fill:#cff,stroke:#333
style D fill:#ffc,stroke:#333
style E fill:#cfc,stroke:#333
style F fill:#fcc,stroke:#333
Combination/Sealed system Figure 1

flowchart
graph TD
A["Vent Pipe"] --> B["Boiler"]
B --> C["Return"]
D["Header Tank"] --> E["Pump"]
E --> F["Control Valve"]
F --> G["Return"]
style A fill:#f9f,stroke:#333
style B fill:#ccf,stroke:#333
style C fill:#cfc,stroke:#333
style D fill:#fcc,stroke:#333
style E fill:#cff,stroke:#333
style F fill:#ffc,stroke:#333
style G fill:#cfc,stroke:#333
Open vented system Figure 2
- STRUCTURE INTRODUCTION

| 1 Air vent valve |
| 2 Magnet bar |
| 3 Drain valve |
| 4 Inlet valve |
| 5 Outlet valve |
4. INSTALLATION METHOD
- Cut and remove the section of the pipe according to the product installation length;
- Install the valves onto the pipework, hand tighten only at first, then tighten securely the valve to the pipe;
- Install the filter housing and tighten it;
- Adjust the Angle and secure the filter;
- Make sure the valves are open, allow the system to fill, open, and vent the filter through the air vent valve, close when complete.
①

natural_image
Simple line drawing of five vertical cylindrical objects with small circular ends, no text or symbols present.②
→

→
③

→
④

5. MAINTENANCE AND SERVICING

Note: Prior to carrying out any maintenance work, isolate the electrical supply to the boiler allowing the water to cool down to a safe working temperature.
- Close both the isolation valves;
- Open the drain valve, place a bucket or similar receptacle below ready to collect the debris. Take out the magnetic bar and store in a safe place;
- Open the inlet valve to flush out the debris, once all the debris has been removed introduce a suitable chemical inhibitor into the system, we recommend Salus LX1 inhibitor, refit the magnetic bar;
- Open the inlet and outlet valve, vent the filter through the air vent valve close when complete. Check for any leaks;
- Complete any relevant documentation.
IE: Dates and inhibitor used.

Note: It is recommended that the magnetic filter is installed and maintained by a competent and qualified person. Any queries arising from either installation or servicing, contact SALUS Controls at techsupport@salus-tech.com
①

②


④

Maximum working pressure: 6bar Maximum operating temperature: 95 °C Flow rate: < 50 l/min Direction of flow: follow the arrow

Please note:
- The magnetic filter contains powerful magnets, please keep away from all electronic devices, bank cards and other magnetic devices;
- The Magnetic Filter contains powerful magnets and should always be used with caution especially for devices such as pacemakers;
- The Magnetic Filter is a pressurized device, pressure must be released prior to maintenance;
- The Magnetic Filter device could be very hot during operation. Please be careful!
* In order to maintain grounding continuity in accordance with the current IEE regulations, appropriate grounding cables should be installed on the pipe where necessary to bypass the product.
Instruction manual of magnetic filter
* Please read the product manual carefully before installation and use.