D8125 - Detector BOSCH - Free user manual and instructions
Find the device manual for free D8125 BOSCH in PDF.
| Product Type | Recessed Magnetic Contact |
| Brand | Bosch |
| Model | D8125 |
| Dimensions (Body) | 1.5 in x 0.5 in (38 mm x 13 mm) |
| Magnet Dimensions | 0.7 in x 0.3 in (18 mm x 8 mm) |
| Weight | Approx. 0.3 oz (8 g) |
| Power | Passive (no external power required) |
| Switch Type | Reed switch (Form A, normally open or closed) |
| Maximum Gap | 0.75 in (19 mm) |
| Wire Length | 12 in (30 cm) pigtail |
| Mounting | Recessed in door/window frame |
| Compatible Panels | Bosch security systems (B8512G, B9512G, etc.) |
| Operating Temperature | -30°F to 150°F (-34°C to 65°C) |
| Tamper Protection | Not included (use with panel tamper) |
| Maintenance | Clean with dry cloth; check wiring periodically |
| Safety | Low voltage (Class 2) device; follow local codes |
| Spare Parts | Magnet and contact assemblies available |
| Repairability | Non-serviceable; replace if defective |
| Warranty | Limited 5 years |
Frequently Asked Questions - D8125 BOSCH
User questions about D8125 BOSCH
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Detector in PDF format for free! Find your manual D8125 - BOSCH and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. D8125 by BOSCH.
USER MANUAL D8125 BOSCH
D8125 Addressable Expansion Module
www.boschsecurity.com

BOSCH
Invented for life

natural_image
Green printed circuit board with various electronic components and connectors (no readable text or symbols)The D8125 Addressable Expansion Module works with the D9127U or D9127T POPIT Modules to provide multiplex technology that combines zone or point supervision with individual device addressing on one pair of wires. Use the D8125 to provide expansion beyond the standard number of control panel zones, up to a total of 238 points. Each D8125 module can fully supervise 119 D9127U or D9127T POPIT Modules.
System overview
Each D8125 installs in the control panel enclosure or in an adjacent approved enclosure. Future system expansion is very economical as D9127U or D9127T POPITs can be spliced in anywhere along the two-wire data expansion loop from the D8125 module.
The D9127 is a compact, addressable device that is suitable for applications where specifications call for point identification from each initiating device or series of devices. The units are small, and easily installed in standard outlet boxes, above false ceilings, closets, or other accessible locations.
The D8125 includes a 33 kΩ end-of-line (EOL) resistor. Install the resistor at the farthest point on the loop for proper supervision.
Certifications and approvals
Australia C-Tick
- Provides point identification of initiating devices
▶ Supervises wiring to devices for circuit integrity
▶ Expands the number of points in the system
▶ Compact size
▶ Terminal connections for reliability
Region Certification
| USA UL AMCX: Central Station Alarm Units(UL1610, UL1635), AMCX7: Central Station Alarm Units Certified for Canada (cULus), AOTX: Local Alarm Units (UL464, UL609), AOTX7: Local Alarm Units Certified for Canada (cULus), APAW: Police Station Alarm Units (UL365, UL464), APAW7: Police Station Alarm Units Certified for Canada (cULus), APOU: Proprietary Alarm Units (UL1076), APOU7: Proprietary Alarm Units Certified for Canada (cULus), NBSX: Household Burglar Alarm System Units (UL1023), NBSX7: Household Burglar Alarm System Units Certified for Canada (cULus), UOJZ: Control Units, System (UL864, 9th edition), UTOU: Control Units and Accessories - House-hold System Type (UL985), UTOU7: Control Units and Accessories - House-hold System Type Certified for Canada (cULus) | |
| FM | |
| CSFM California State Fire Marshal (see our website) | |
| FDNY-CoA 6174 | |
| FDNY-CoA 6059 [D9412GV3 & D7412GV3] | |
Region Certification
| NYC-MEA | 12-92-E, Vol. 12 12-92-E, Vol. 12 | |
| NYC-MEA | 12-92-E, Vol. 15 12-92-E, Vol. 15 | |
| NYC-MEA | 12-92-E, Vol. II 12-92-E, Vol. II | |
| Canada ULC AMCX7.S1871 - Central Station Alarm Units Certified for Canada | ||
| ULC S303 - Local Burglar Alarm Units and Systems | ||
| ULC - Police Station Connected Burglar Alarm Units | ||
| ULC APOU7.S1871 Proprietary Alarm Units Certified for Canada | ||
| ULC ULC-ORD C1023 - Household Burglar Alarm System Units | ||
Installation/configuration notes
Compatible Control Panels
• B9512G/B9512G-E
• B8512G/B8512G-E
• D9412GV4/D7412GV4/D7212GV4
• D9412GV3/D7412GV3/D7212GV3
• D9412GV2/D7412GV2/D7212GV2
• D9412/D7412/D7212
• D7212B1
• D9112/D9112B1
• D8112G1/D8112G2
• D9124
Parts included
Quantity Component
1 Expansion board
1 Hardware pack
1 Literature pack
Technical specifications
Properties
Dimensions: 13 cm x 8 cm x 2 cm (5 in. x 3 in. x 0.75 in.)
Power Requirements
Current Draw: 50 mA for each D8125 module
Voltage (Operating): 12 VDC
Ordering information
D8125 Addressable Expansion Module
Provides expansion up to 238 points.
Order number D8125
Represented by:
Europe, Middle East, Africa: North America: Asia-Pacific:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: +31 40 2577 284
emea.securitysystems@bosch.com
emea.boschsecurity.com
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 00
Fax: +1 585 223 9180
onlinehelp@us.bosch.com
www.boschsecurity.us
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com