| Product Type | Indoor/Outdoor Security Camera |
| Model | UC-261 |
| Brand | Joblotron |
| Resolution | 1080p Full HD (1920 x 1080) |
| Field of View | 120° diagonal |
| Night Vision | Up to 30 ft (10 m) with IR LEDs |
| Motion Detection | Yes, with notifications via app |
| Audio | Built-in microphone and speaker (two-way audio) |
| Connectivity | Wi-Fi 802.11 b/g/n (2.4 GHz) |
| Power Supply | DC 5V/1A via micro USB cable |
| Mount Type | Wall or ceiling mount included |
| Weatherproof Rating | IP65 (dust-tight and water-resistant) |
| Storage | MicroSD card (up to 128 GB) and cloud storage |
| Dimensions | 2.8 x 2.8 x 4.5 inches (7.1 x 7.1 x 11.4 cm) |
| Weight | 10.6 oz (300 g) |
| Operating Temperature | -4°F to 122°F (-20°C to 50°C) |
| Compatible Systems | iOS and Android |
| Recording Mode | Continuous, motion-triggered, or scheduled |
| Maintenance | Wipe lens with dry cloth; check connections |
| Safety | Designed for indoor/outdoor use; keep dry |
Frequently Asked Questions - UC-261 Jablotron
User questions about UC-261 Jablotron
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Security Camera in PDF format for free! Find your manual UC-261 - Jablotron and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UC-261 by Jablotron.
USER MANUAL UC-261 Jablotron
The UC-261 wireless indoor siren
The UC-261 indoor siren communicates wirelessly with the control panel (two way communication). It can be used as a wireless indoor siren and at the same time as a melody doorbell or as a chime indicator. The UC-261 is compatible with Jablotron wireless control panels (JA-63 and JA-65), JA-60 wireless detectors and RC-4x, RC-22 and RC-28 remote controls. Several triggering devices can be used simultaneously and different melodies can be assigned to each device. Two different sound levels can be selected. The UC-261 can also provide entrance and exit delay chirps when used with a control panel. In addition, if the UC-261 is disconnected from the power it will send an error report to the control panel.
Specification
Power supply 230 V, 50 Hz
Power consumption 1 W
Acoustics 8 melodies and/or 100 dB/m alarm siren
Input wireless devices max. 8 remote controls or detectors
1 control panel, JA-63 or JA-65
Class II according to EN60950
Working frequency 433.92 MHz
Environmental conditions indoors -10 to +40°C
Safety standards IP40 according to EN 60529, IEC 529
Jablotron Ltd. hereby declares that the UC-261 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
The original of the conformity assessment can be found at www.jablotron.com, Technical Support section.
Installation
The UC-261 is powered directly from a power outlet. The device should not be installed close to any metal structures or other objects obstructing radio signal transmissions.
Enrolling of wireless devices:
- To enroll the JA-63 or 65 control panel switch the control panel to enrollment mode.
- While pressing and holding a button on the UC-261, plug it into the outlet to transmit the enrollment signal.
- Release the button when you hear two beeps. The flashing button indicates that it is in programming mode. Consequently the UC-261 will be enrolled to siren position "A".
- If another wireless siren has already been enrolled to the control panel, then it is necessary to enroll the UC-261 to a detector position by entering 000000 in control panel enrollment mode before plugging the UC-261 into the outlet (see also the control panel manual).
- Exit enrollment mode of the control panel by pressing N.
- If it is necessary to enroll other devices to the UC-261, see following procedure (points 7 to 9). Or exit programming mode by briefly pressing the button on the UC-261.
NOTE:
- If position "A" is occupied and you plug the UC-261 into the outlet in control panel enrollment mode, then the former item (e.g. JA-60A) will be deleted.
- Only one control panel can be enrolled to the UC-261 but more UC-261 units can be enrolled to one control panel.

flowchart
graph TD
A["Wireless buttons - doorbell"] --> B["Mr. Brown"]
B --> C["RC-28"]
C --> D["RC-22"]
E["Alarm - Siren"] --> F["Control panel JA-6x"]
F --> G["Movement JA-60P"]
G --> H["JA-60detectors - notification"]
I["Door open JA-60N"] --> J["JA-60N"]
UC-261 wireless indoor siren 1 / 2 MFI52702
The UC-261 wireless indoor siren
The UC-261 indoor siren communicates wirelessly with the control panel (two way communication). It can be used as a wireless indoor siren and at the same time as a melody doorbell or as a chime indicator. The UC-261 is compatible with Jablotron wireless control panels (JA-63 and JA-65), JA-60 wireless detectors and RC-4x, RC-22 and RC-28 remote controls. Several triggering devices can be used simultaneously and different melodies can be assigned to each device. Two different sound levels can be selected. The UC-261 can also provide entrance and exit delay chirps when used with a control panel. In addition, if the UC-261 is disconnected from the power it will send an error report to the control panel.
Specification
Power supply 230 V, 50 Hz
Power consumption 1 W
Acoustics 8 melodies and/or 100 dB/m alarm siren
Input wireless devices max. 8 remote controls or detectors
1 control panel, JA-63 or JA-65
Class 11 according to EN60950 Working frequency: 422.02 MHz
Working frequency 455.92 MHz
Environmental conditions indoors = 10 to +40 °C Safety standards, IP40 according to EN 60529, IEC 529
Jablotron Ltd. hereby declares that the UC-261 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
The original of the conformity assessment can be found at www.jablotron.com, Technical Support section.
Installation
The UC-261 is powered directly from a power outlet. The device should not be installed close to any metal structures or other objects obstructing radio signal transmissions.
Enrolling of wireless devices:
- To enroll the JA-63 or 65 control panel switch the control panel to enrollment mode.
- While pressing and holding a button on the UC-261 plug it into the outlet to transmit the enrollment signal.
- Release the button when you hear two beeps. The flashing button indicates that it is in programming mode. Consequently the UC-261 will be enrolled to siren position "A".
- If another wireless siren has already been enrolled to the control panel, then it is necessary to enroll the UC-261 to a detector position by entering 000000 in control panel enrollment mode before plugging the UC-261 into the outlet (see also the control panel manual).
- Exit enrollment mode of the control panel by pressing N.
- If it is necessary to enroll other devices to the UC-261, see following procedure (points 7 to 9). Or exit programming mode by briefly pressing the button on the UC-261.
NOTE:
- If position "A" is occupied and you plug the UC-261 into the outlet in control panel enrollment mode, then the former item (e.g. JA-60A) will be deleted.
- Only one control panel can be enrolled to the UC-261 but more UC-261 units can be enrolled to one control panel.

flowchart
graph TD
A["Wireless buttons - doorbell"] --> B["MR. Brown"]
B --> C["RC-28"]
C --> D["RC-22"]
E["Alarm - Siren"] --> F["Control panel JA-6x"]
F --> G["Movement JA-60P"]
G --> H["JA-60 detectors - notification"]
I["Door open JA-60N"] --> J["JA-60N"]
UC-261 wireless indoor siren 1 / 2 MFI52702
- A remote control or doorbell button (RC-4x, RC-22, RC-28) can be enrolled by pressing the button on the controller. Multiple pressing of the controller's button will allow you to scroll to the desired melody.
- Detector-chime mode: JA-60 detectors can be enrolled by inserting batteries into them, one detector at a time. By triggering the tamper on a detector you can scroll to the desired melody.
- Exit programming mode by briefly pressing the button on the UC-261.
Up to 8 doorbell buttons or detectors can be used with one UC-261.
If you enter programming mode the above way, all previously enrolled devices will be erased from the UC-261 memory.
If you want to add additional doorbell buttons or detectors, or if you want to select another melody for an existing device, then: - Unplug the UC-261 from the outlet and wait for 5 seconds.
- Plan to wait
- Plug it in again.
- When the button lights – press it and hold it down. After hearing a short beep, release the button. The flashing button indicates that it is in programming mode.
- Enrolling new devices (or selecting another melody):
- A doorbell button or remote control (RC-4x, RC-22, RC-28) can be enrolled by pressing the button on the controller. Multiple pressing of the controller's button will allow you to scroll to the desired melody.
- Detector-chime mode: JA-60 detectors can be enrolled by inserting batteries into them, one detector at a time. By triggering the tamper on a detector you can scroll to the desired melody.
- Exit programming mode by briefly pressing the button on the UC-261.
Press and hold the button on the UC-261 and plug the UC-261 into the mains outlet. Two beeps will be heard and all devices including the control panel will then be erased.
Consequently it is necessary to erase the UC-261 from the control panel. In control panel enrollment mode scroll to the UC-261 position, press and hold button 2 until the confirmation beep can be heard.
Note: If the memory of the UC-261 is deleted but the UC-261 is not erased from the control panel, then the control panel will indicate disconnection of the UC-261 from the power but the UC-261 will not react to signals from the control panel – in the case of an alarm it will not sound. - The UC-261 must be in its normal operating mode (plugged in).
- Press and hold the button down.
• After 2 seconds you will hear a melody with the new loudness selected - Release the button.
This way you can toggle between a standard and a quieter level. This setting does not affect the alarm siren sound.
Note
Enrolling additional devices
Deleting enrolled devices
Loudness selection
Power failure
If the UC-261 is disconnected from its power (it is unplugged or there is a power failure), then a "Low battery" report will be transmitted to the control panel. In addition if the system is in alarm mode (the sirens are sounding) the UC-261 will also transmit a *TAMPER* signal.
Doorbell-mode
After pressing a doorbell button, the UC-261 will play a preselected melody. Different melodies can be assigned to each doorbell button, if desired. If you want to change a melody, enter programming mode (see section "Enrolling Additional Devices") and press the button until the desired melody is selected.
Detector-chime mode
If an enrolled detector is triggered, the UC-261 will play a pre-selected melody. The melody can be changed if desired (see section "Enrolling Additional Devices").
A detector enrolled to the UC-261 can be simultaneously enrolled to a JA-63 or JA-65 control panel. This way, for example, a wireless door detector can activate a chime on the UC-261 and at the same time trigger an alarm.
Notes:
1/ The JA-60P motion detector has a special sleep mode feature (settable to 5 min. or 1 min.). Therefore it cannot detect more frequent movements in a covered area.
2/ The JA-60SP, JA-60SR fire detectors and JA-60G cannot be used for chime mode.
Wireless siren mode
The UC-261's light indicator shows the status of the PgY output of the enrolled control panel. If an alarm is triggered, the UC-261 siren sounds, ARM and DISARM chirps can be enabled or disabled by the following procedure:
- Unplug the UC-261 from the outlet and wait for 5 seconds.
- Plug it in again.
- When the button lights – press it and hold it down. After hearing a short beep, release the button. The flashing button indicates that it is in programming mode.
- On the control panel in P mode enter 299 repeatedly to toggle between these two settings:
- When one beep is heard, no chirps will be performed by the UC-261
- When two beeps are heard, both ARM and DISARM chirps will be performed by the UC-261.

Note: Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the producer after use.

- A remote control or doorbell button (RC-4x, RC-22, RC-28) can be enrolled by pressing the button on the controller. Multiple pressing of the controller's button will allow you to scroll to the desired melody.
- Detector-chime mode: JA-60 detectors can be enrolled by inserting batteries into them, one detector at a time. By triggering the tamper on a detector you can scroll to the desired melody.
- Exit programming mode by briefly pressing the button on the UC-261.
Note:
Up to 8 doorbell buttons or detectors can be used with one UC-261.
If you enter programming mode the above way, all previously enrolled devices will be erased from the UC-261 memory.
Enrolling additional devices
If you want to add additional doorbell buttons or detectors, or if you want to select another melody for an existing device, then:
1. Unplug the UC-261 from the outlet and wait for 5 seconds.
2. Plaiting a bus
2. Plug it in again.
3. When the button lights – press it and hold it down. After hearing a short beep, release the button. The flashing button indicates that it is in programming mode.
4. Enrolling new devices (or selecting another melody):
- A doorbell button or remote control (RC-4x, RC-22, RC-28) can be enrolled by pressing the button on the controller. Multiple pressing of the controller's button will allow you to scroll to the desired melody.
- Detector-chime mode: JA-60 detectors can be enrolled by inserting batteries into them, one detector at a time. By triggering the tamper on a detector you can scroll to the desired melody.
5. Exit programming mode by briefly pressing the button on the UC-261.
Deleting enrolled devices
Press and hold the button on the UC-261 and plug the UC-261 into the mains outlet. Two beeps will be heard and all devices including the control panel will then be erased.
Consequently it is necessary to erase the UC-261 from the control panel. In control panel enrollment mode scroll to the UC-261 position, press and hold button 2 until the confirmation beep can be heard.
Note: If the memory of the UC-261 is deleted but the UC-261 is not erased from the control panel, then the control panel will indicate disconnection of the UC-261 from the power but the UC-261 will not react to signals from the control panel – in the case of an alarm it will not sound.
Loudness selection
- The UC-261 must be in its normal operating mode (plugged in).
- Press and hold the button down.
• After 2 seconds you will hear a melody with the new loudness selected - Release the button.
This way you can toggle between a standard and a quieter level. This setting does not affect the alarm siren sound.
Power failure
If the UC-261 is disconnected from its power (it is unplugged or there is a power failure), then a "Low battery" report will be transmitted to the control panel. In addition if the system is in alarm mode (the sirens are sounding) the UC-261 will also transmit a "TAMPER" signal.
Doorbell-mode
After pressing a doorbell button, the UC-261 will play a preselected melody. Different melodies can be assigned to each doorbell button, if desired. If you want to change a melody, enter programming mode (see section "Enrolling Additional Devices") and press the button until the desired melody is selected.
Detector-chime mode
If an enrolled detector is triggered, the UC-261 will play a pre-selected melody. The melody can be changed if desired (see section "Enrolling Additional Devices").
A detector enrolled to the UC-261 can be simultaneously enrolled to a JA-63 or JA-65 control panel. This way, for example, a wireless door detector can activate a chime on the UC-261 and at the same time trigger an alarm.
Notes
1/ The JA-60P motion detector has a special sleep mode feature (settable to 5 min. or 1 min.). Therefore it cannot detect more frequent movements in a covered area.
2/ The JA-60SP, JA-60SR fire detectors and JA-60G cannot be used for chime mode.
Wireless siren mode
The UC-261's light indicator shows the status of the PgY output of the enrolled control panel. If an alarm is triggered, the UC-261 siren sounds. ARM and DISARM chirps can be enabled or disabled by the following procedure:
- Unplug the UC-261 from the outlet and wait for 5 seconds.
- Plug it in again.
- When the button lights – press it and hold it down. After hearing a short beep, release the button. The flashing button indicates that it is in programming mode.
- On the control panel in P mode enter 299 repeatedly to toggle between these two settings:
- When one beep is heard, no chirps will be performed by the UC-261.
- When two beeps are heard, both ARM and DISARM chirps will be performed by the UC-261.

Note: Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the producer after use.