CDA TC66CH - Faucet

TC66CH - Faucet CDA - Free user manual and instructions

Find the device manual for free TC66CH CDA in PDF.

📄 2 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice CDA TC66CH - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Kitchen Faucet
Brand CDA
Model TC66CH
Material Brass
Finish Chrome
Spout Height 8.7 inches (22 cm)
Spout Reach 7.9 inches (20 cm)
Number of Handles 1
Handle Type Single Lever
Valve Type Ceramic Disc
Flow Rate 1.5 GPM (5.7 L/min)
Maximum Pressure 60 PSI (4.1 bar)
Connection Size 3/8 inch compression
Installation Type Deck Mount, 1 or 3 hole
Included Components Faucet body, handle, mounting hardware, water supply lines
Certifications NSF 61, ANSI
Care Instructions Clean with mild soap and water; avoid abrasive cleaners
Warranty Limited Lifetime
Country of Origin China

Frequently Asked Questions - TC66CH CDA

How do I install the CDA TC66CH faucet?
Installation requires basic plumbing skills. Ensure water supply is off. Follow the included manual: mount the faucet through the deck, secure with provided nuts, connect supply lines to shut-off valves, and tighten connections. Use a basin wrench for hard-to-reach areas.
What tools are needed for installation?
You will need an adjustable wrench, basin wrench, plumber's tape (Teflon), screwdriver, and possibly a drill for new holes. Most hardware is included.
Can I use this faucet with a water filter?
Yes, the faucet has standard 3/8-inch compression connections that can be adapted to most under-sink water filter systems. Check compatibility with your filter's hose size.
Is the faucet lead-free?
Yes, the CDA TC66CH is made from lead-free brass, complying with NSF 61 standards for safe drinking water.
How do I clean the faucet?
Clean with a soft cloth and mild soapy water. Rinse thoroughly. Avoid abrasive cleaners, scouring pads, or harsh chemicals that may damage the chrome finish.
What is the warranty coverage?
CDA offers a limited lifetime warranty against manufacturing defects. This covers the faucet body and finish for as long as you own the product. Cartridges and other parts are covered for 5 years.
Can I install it on a 3-hole sink?
Yes, the faucet is designed for 1-hole or 3-hole installation (with included deck plate). For 3-hole sinks, use the escutcheon plate provided to cover extra holes.
Does the faucet include supply lines?
Yes, the package includes two 3/8-inch compression supply lines (hot and cold). They are typically 20 inches long.
What is the maximum pressure rating?
The faucet is rated for a maximum water pressure of 60 PSI (4.1 bar). Higher pressure may cause leaks or damage; use a pressure regulator if needed.
How do I replace the cartridge?
Turn off water supply. Remove the handle by unscrewing the set screw. Unscrew the cartridge retaining nut, remove the old cartridge, and install a new one (standard 35mm ceramic disc). Reassemble in reverse order.

User questions about TC66CH CDA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Faucet in PDF format for free! Find your manual TC66CH - CDA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TC66CH by CDA.

USER MANUAL TC66CH CDA

TC66 - Side single lever with quad spout

Five Year warranty:

In the unlikely event that you should experience any defect in the materials or workmanship of your new mixer within FIVE years of purchase, the purchaser's sole remedy shall be the replacement (at the manufacturer's discretion) of all or any part of the product that is defective. All working parts and valves are guaranteed for a period of FIVE years from purchase. Decorative surface finishes and O-rings are guaranteed for ONE year from the date of purchase provided that our advice concerning care has been observed. This guarantee is valid providing that the mixer tap has been used for normal domestic purposes in the UK and that the care, installation and maintenance instructions have been observed. The warranty extends to the original purchaser only. You should retain a copy of your dated invoice as proof of purchase to validate any claims under this guarantee.

Care Instructions for your Kitchen Sink Mixer:

To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp cloth. A solution of warm water and a mild liquid detergent may be used where necessary, and then the fitting rinsed thoroughly and wiped dry. Any other cleaning action will invalidate your warranty. If the tap has a diffuser it should be cleaned periodically.

Abrasive cleaners, scouring cleaners and acidic cleaners must not be used under any circumstances. Avoid contact with all solvents (including chlorinated solvents, ketones or acetones as these may result in surface deterioration or etching). Also avoid contact with any harsh household chemicals such as oven cleaners, drain cleaners, rust removers, paint strippers and toilet bowl cleaners, bar keepers friend or Brasso.

Important Technical Data:

Minimum operating pressure 0.5 bar Maximum hot water temperature 70°C*

Maximum operating pressure 5.5 bar* Recommended hot water temperature 46°C

*If these temperatures or pressures are exceeded, even for short periods, damage can result.

CDA taps are either WRAS approved or manufactured in accordance with recognised European standards. Please ensure that your Kitchen mixer is fitted in accordance with Local Water Byelaws.

These installation guidelines have been prepared for your direction and you must exercise due care at all times. We do not accept responsibility for problems that may occur through improper installation. Whilst assembling the tap take care not to accidentally loosen any screwed assemblies.

Installation Preparation:

Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any remaining solder, swarf or impurities from your system. Failure to carry out this simple procedure could cause problems or damage to the workings of the mixertap.

We strongly recommend installing particle filter strainers and isolation valves to both the hot and cold feed pipes in an accessible position. This will help to prevent premature failure of the valves and ease any future maintenance.

All parts should be removed from their packaging and inspected for any transport damage prior to installation.

Shut off your water heating system and ensure that your mains stopcock is closed. Open the lowest hot and cold taps in the house and allow the water to run until the cold-water storage tank and pipes are fully empty. Please note, the hot water storage cylinder (if applicable) will always remain full.

This mixertap requires a 35mm∅ tap hole, if replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool the tap hole area should be free from dirt and sealant.

Loosely position the tap and tail pipes to check if any alteration to the existing pipework is required, if this is the case do this now.

Installation:

  1. Screw in the studded rod (D) into the base of the tap (A).
  2. Place the base plinth (B) then upper seal (C) onto the base of the tap (A).
  3. Screw the hot & cold water tail pipes (H) into the base of the tap.
  4. Place the mixertap (A) onto the sink or worktop, pass the tail pipes (H) and studded rod (D) through the taphole.
  5. Pass the rubber and then metal horseshoe (E&F) over the studded rod (D) and around the tail pipes.
  6. Fasten the fixing nut (G) securely onto the fixing stud (D) to fix the tap into its correct location.
  7. Connect the hot and cold tail pipes (H) to the water mains using a 12 " BSPx15mm compression fittings.
Key:Description: Qty
AMixertap body 1
BBase plinth 1
CUpper seal 1
DFixing stud 1
ERubber horseshoe 1
FMetal horseshoe 1
GFixing nut 1
HHot & cold flexible tail pipes 2

Technical diagram of a mechanical or fluid system with labeled components A through H, showing connections and structural elements.

After installation:

Once you have visually checked the new fittings and connections, ensure that all taps are closed except the new mixer tap, which should be left open. Turn on the water supply at the mains stop cock. As the system starts to refill, check carefully for leaks. Once you are fully satisfied that there are no leaks, turn on the water heating.

Clean the tap to remove any marks created during installation as instructed then replace the bag that has been provided to protect the tap until it is ready for use.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : CDA

Model : TC66CH

Category : Faucet