Product Type Faucet (single lever mixer tap)
Brand CDA
Model TC15CH
Type Low pressure single lever kitchen mixer tap
Minimum Operating Pressure 0.3 bar
Maximum Operating Pressure 5.5 bar
Maximum Hot Water Temperature 70°C
Recommended Hot Water Temperature 46°C
Tap Hole Diameter Required 35 mm
Approvals WRAS approved or manufactured to European standards
Warranty (Working Parts) 5 years from purchase
Warranty (Finishes & O-rings) 1 year from purchase
Care Instructions Clean with soft damp cloth; mild detergent if needed; no abrasive or acidic cleaners; avoid solvents and harsh chemicals
Installation Preparation Flush supply pipes, install particle filter strainers and isolation valves, shut off water supply
Included Components Mixer tap body, upper seal, studded rod, rubber washer, metal horseshoe, fixing nut, hot and cold tail pipes, compression nut & olive, non-return valve
Connection Type 15mm compression fittings

Frequently Asked Questions - TC15CH CDA

What is the minimum water pressure required for the CDA TC15CH faucet?
The minimum operating pressure is 0.3 bar.
How do I clean the CDA TC15CH faucet to maintain its appearance?
Use a clean, soft damp cloth. For stubborn dirt, a solution of warm water and mild liquid detergent can be used, then rinse thoroughly and wipe dry. Avoid abrasive cleaners, scouring pads, acidic cleaners, solvents, and harsh household chemicals like oven cleaners or drain cleaners.
What is the warranty period for the CDA TC15CH faucet?
Working parts and valves are guaranteed for 5 years from purchase. Decorative surface finishes and O-rings are guaranteed for 1 year. The warranty applies to the original purchaser for normal domestic use in the UK.
Can the CDA TC15CH be installed on any sink?
The faucet requires a 35 mm diameter tap hole. Ensure your sink or worktop has a suitable hole. If replacing an existing tap, clean the area and check the pipework alignment.
What should I do if the faucet drips after installation?
First, check that all connections are tight. Ensure the non-return valve and compression fittings are correctly installed. If dripping persists, inspect the valve cartridges and O-rings, which may need replacement under warranty.
Does the CDA TC15CH require any special tools for installation?
Basic plumbing tools such as adjustable spanners, pipe cutters, and a screwdriver are needed. Compression fittings require a spanner. Ensure you have wire wool for cleaning pipe ends.
Can I use the faucet with a combi boiler?
Yes, as long as the water pressure is within the operating range (0.3 to 5.5 bar). The faucet is suitable for low pressure systems, so it works well with combi boilers.
How do I replace the tap's diffuser?
The diffuser is not explicitly mentioned in the manual, but if your model has one, it can be unscrewed from the spout. Clean it with mild soapy water and a soft brush. Reattach firmly.
Is the CDA TC15CH WRAS approved?
Yes, CDA taps are either WRAS approved or manufactured in accordance with recognized European standards, ensuring compliance with UK water regulations.
What should I do before installing the faucet?
Thoroughly flush the supply pipes to remove debris. Install particle filter strainers and isolation valves on both hot and cold feeds. Shut off the water supply and drain the system before installation.

User questions about TC15CH CDA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Faucet in PDF format for free! Find your manual TC15CH - CDA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TC15CH by CDA.

USER MANUAL TC15CH CDA

TC15 - Low pressure single lever

Five Year warranty:

In the unlikely event that you should experience any defect in the materials or workmanship of your new CDA mixer tap within FIVE years of purchase, the purchaser's sole remedy shall be the replacement (at the manufacturer's discretion) of all or any part of the product that is defective. All working parts and valves are guaranteed for a period of FIVE years from purchase. Decorative surface finishes and O-rings are guaranteed for ONE year from the date of purchase. This guarantee is valid providing that the mixer tap has been used for normal domestic purposes in the UK and that the care, installation and maintenance instructions have been observed. The warranty extends to the original purchaser only. You should retain a copy of your dated invoice as proof of purchase to validate any claims under this guarantee.

Care Instructions for your Kitchen Sink Mixer:

To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp cloth. A solution of warm water and a mild liquid detergent may be used where necessary, and then the fitting rinsed thoroughly and wiped dry. Any other cleaning action will invalidate your warranty. If the tap has a diffuser it should be cleaned periodically.

Abrasive cleaners, scouring cleaners and acidic cleaners must not be used under any circumstances. Avoid contact with all solvents (including chlorinated solvents, ketones or acetones as these may result in surface deterioration or etching). Also avoid contact with any harsh household chemicals such as oven cleaners, drain cleaners, rust removers, paint strippers and toilet bowl cleaners, bar keepers friend or Brasso.

Important Technical Data:

Minimum operating pressure 0.3 barMaximum hot water temperature 70^ *
Maximum operating pressure 5.5 bar*Recommended hot water temperature 46^

*If these temperatures or pressures are exceeded, even for short periods, damage can result.

CDA taps are either WRAS approved or manufactured in accordance with recognised European standards. Please ensure that your Kitchen mixer is fitted in accordance with Local Water Byelaws.

These installation guidelines have been prepared for your direction and you must exercise due care at all times. We do not accept responsibility for problems that may occur through improper installation. Whilst assembling the tap take care not to accidentally loosen any screwed assemblies.

Installation Preparation:

Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any remaining solder, swarf or impurities from your system. Failure to carry out this simple procedure could cause problems or damage to the workings of the mixertap.

We strongly recommend installing particle filter strainers and isolation valves to both the hot and cold feed pipes in an accessible position. This will help to prevent premature failure of the valves and ease any future maintenance.

All parts should be removed from their packaging and inspected for any transport damage prior to installation.

Shut off your water heating system and ensure that your mains stopcock is closed. Open the lowest hot and cold taps in the house and allow the water to run until the cold-water storage tank and pipes are fully empty. Please note, the hot water storage cylinder (if applicable) will always remain full.

This mixertap requires a 35mm∅ tap hole, if replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool the tap hole area should be free from dirt and sealant.

Loosely position the tap and tail pipes to check if any alteration to the existing pipework is required, if this is the case do this now.

Installation:

  1. Screw the studded rod (C) into the base of the tap (A).
  2. Screw the copper tail pipes (G&H) into the base of the tap, note the hot water should be connected to the left of the tap when viewed from the front.
  3. Pass the upper seal (B) over the studded rod (C) and tail pipes (G&H) and locate it centrally on the base of the mixertap (A).
  4. Place the mixertap (A) onto the sink or worktop and pass the tail pipes (G&H) and studded rod (C) through the taphole. With the tap in place check that the tail pipes (G&H) meet the hot and cold water feeds. If further adjustment to the plumbing is required do this now. Note: the tail pipes can be carefully bent apart to allow more space for fittings to be attached.
  5. Pass the rubber washer (D) and then metal horseshoe (E) over the studded rod (C) and around tail pipes (G&H).
  6. Fasten the fixing nut (F) securely onto the fixing stud (C) fixing the tap into its correct location.
  7. Connect the Non return valve (K) to the cold water tail pipe (H) using compression nut & olive (I&J)
  8. Connect the Hot water tail pipe (G) to the hot water supply using 15mm compression fitting or similar.
  9. Connect the Non return valve (K) to pipe to the cold water supply using a 12 " BSP x 15mm compression fitting or similar.
KeyDescription Qty
AMixertap body 1
B Upper sink/worktop seal 1
CStudded rod 1
DRubber washer 1
EMetal horseshoe 1
FFixing nut 1
G Hot rigid 15mm tail pipe 1
H Cold rigid 15mm tail pipe1
ICompression Nut1
JCompression Olive1
K Non return valve 1

A B C D E F G H I J K

After installation:

Once you have visually checked the new fittings and connections, ensure that all taps are closed except the new mixer tap, which should be left open. Turn on the water supply at the mains stop cock. As the system starts to refill, check carefully for leaks. Once you are fully satisfied that there are no leaks, turn on the water heating.

Clean the tap to remove any marks created during installation as instructed then replace the bag that has been provided to protect the tap until it is ready for use.