Product Type Wind Direction Sensor
Model WE570
Measurement Parameter Wind Direction (0-360°)
Output Signal 4-19 mA (two-wire)
Measurement Range 0 to 360° (352° electrical, 8° open)
Accuracy ±1% of full scale
Operating Voltage 10-36 VDC
Current Draw Same as sensor output (4-19 mA)
Warm-Up Time 3 seconds minimum
Operating Temperature Range -40°C to +55°C
Dimensions (Diameter x Length) 8.5" x 10.5"
Weight 1 lb (0.45 kg)
Sensor Type Two-wire (power and signal)
Wiring Red: Power (+), Black: Signal (Output)
Mounting Stainless steel elbow for 1" diameter tube
Installation Orientation Mount parallel to ground surface
Direction Reference Ridge on fixed portion indicates 0° direction
Calibration Frequency Annually recommended
Cleaning Wipe with damp cotton cloth; do not submerge
Warranty 1 year from date of shipment
Compatible Systems Accepts 4-20 mA input (PLC, RTU, data loggers)

Frequently Asked Questions - WE570 Global Water

What is the Global Water WE570?
The Global Water WE570 is a wind direction sensor that measures wind direction from 0 to 360° with a 4-19 mA output signal. It is part of the Global Water weather sensor family.
How do I install the WE570 wind direction sensor?
Mount the sensor using the provided stainless steel elbow on a 1" diameter tube. Ensure the sensor is mounted parallel to the ground for accurate readings. The ridge on the fixed portion indicates the 0° direction.
What is the output signal of the WE570?
The WE570 provides a 4-19 mA output signal. This is a two-wire sensor: red wire for power, black wire for signal. The output can be converted to voltage using a precision resistor (e.g., 125 ohms for 0.5-2.5 VDC).
What power supply does the WE570 require?
The sensor operates on 10-36 VDC. The current draw equals the sensor output (4-19 mA). Always connect the sensor with the power turned off.
How accurate is the WE570?
The WE570 has an accuracy of ±1% of full scale over the 0-360° range.
How do I clean the WE570 sensor?
Clean the sensor periodically using a damp cotton cloth. Do not submerge the sensor as it is water resistant, not waterproof.
How often should I calibrate the WE570?
Global Water recommends confirming calibration annually to ensure accurate measurements.
What is the warm-up time for the WE570?
The sensor requires a minimum warm-up time of 3 seconds before taking readings to ensure it is fully operational.
What should I do if the WE570 reads incorrectly?
First, verify the power supply voltage. Then clean the sensor and confirm calibration. If issues persist, contact Global Water technical support at 800-876-1172 with model number and serial number.
What is the warranty period for the WE570?
The WE570 is covered by a one-year warranty from the date of shipment against defects in materials and workmanship. The warranty does not cover misuse or unauthorized repairs.

User questions about WE570 Global Water

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Weather Station in PDF format for free! Find your manual WE570 - Global Water and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. WE570 by Global Water.

USER MANUAL WE570 Global Water

Global Water

Instrumentation, Inc.

151 Graham Road

P.O. Box 9010

College Station, TX 77842-9010

T: 800-876-1172

Int'l: (979) 690-5560, F: (979) 690-0440

Barometric Pressure: WE100

Solar Radiation: WE300

Wind Speed: WE550

Wind Direction: WE570

Humidity: WE600

Temperature Sensor: WE700

Solar Shield: WE770

Global Water WE570 - Global Water - 1

Global Water

800-876-1172 • globalw.com

Congratulations on your purchase of the Global Water Weather Sensor. This instrument has been quality tested and approved for providing accurate and reliable measurements. We are confident that you will find the sensor to be a valuable asset for your application. Should you require assistance, our technical staff will be happy to help.

Table of Contents

I. ChecklistPage3
II. Inspection3
III. General Sensor Installation4
IV. Barometric Pressure Sensor5
V. Solar Radiation Sensor7
VI. Wind Speed Sensor8
VII. Wind Direction Sensor9
VIII. Humidity Sensor10
IX. Temperature Sensor11
X. Solar Shield12
XI. Maintenance12
XII. Troubleshooting13
XIII. Warranty15
XIV. Appendix A: Temperature Calibration Check16
XV. Appendix B: 2 Wire Sensor Measurement Diagram17
XVI. Appendix C: 3 Wire Sensor Measurement Diagram18

* Copyright © Global Water Instrumentation, Inc. 2002

Global Water WE570 - 800-876-1172 • globalw.com - 1

Global Water

800-876-1172 • globalw.com

I. Sensor Checklist

a. Weather Sensor

b. Weather Sensor Manual

II. Inspection

a. Your Weather sensor was carefully inspected and certified by our Quality Assurance Team before shipping. If any damage has occurred during shipping, please notify Global Water Instrumentation, Inc. and file a claim with the carrier involved.

Use the checklist to ensure that you have received everything needed to operate the weather instrument(s).

Global Water WE570 - Inspection - 1

Global Water

800-876-1172 • globalw.com

III. General Sensor Installation

a. Weather sensors have many applications and therefore many installation options. The sensors should be located in a clear area on a level surface.

b. Install your Weather sensor so that it is easily accessible for calibration purposes. You may need to remove and reinstall it in the future, so plan ahead!

c. All Global Water Weather sensors produce a 4-20 mA output signal. 4-20 mA is an industrial standard signal for process control monitoring. Most PLCs (Programmable Logic Controller), RTUs (Remote Telemetry Unit), and data acquisition systems accept this signal directly. If the system only accepts voltage signals, the sensor output must be converted to a voltage signal by reading the voltage across a precision resistor in series with the signal wire. Since Ohms Law states that V = IR, if the 4-20 mA signal is dropped across a 250 ohm resistor, the output will be 1 to 5 volts DC. If the 4-20 mA signal is dropped across a 125 ohm resistor, the output will be halved to 0.5 to 2.5 VDC. The 4-20 signal wire is connected to the datalogger voltage input terminal. The resistor is placed between this input and the ground terminal of the datalogger's battery. The power (or voltage to the sensor) must be connected to positive battery terminal of the datalogger.

d. The sensors may be pulsed on or turned on by the logging system prior to taking a reading. Use a warm up time appropriate to the Weather sensor you are using to assure that the sensor is fully on. The sensors can run continuously for real time applications. Each sensor draws between 4 and 20 mA depending on whether the sensor is reading at the minimum or maximum of its range.

e. Weather sensors may be stored without any special provisions. Place the sensor inside a bag to keep the sensor clean and store on a shelf or hang it on a wall.

Global Water WE570 - General Sensor Installation - 1

Global Water

800-876-1172 • globalw.com

IV. Barometric Pressure Sensor

a. Barometric Pressure sensor specifications.

Output: 4-19mA

Range: 800-1100 millibars

Accuracy: +1% of full scale

Operating Voltage: 10-36VDC

Current Draw: Same as sensor output

Warm Up Time: 3 seconds minimum

Operating Temperature: -40° to +55° C

Size of Probe: 3"x2"x1"

Weight: .13 lb.

b. The sensor is a two-wire sensor using the red wire for power and the black wire for the output signal. Warning: Always connect the sensor with the power turned off.

c. The barometric pressure sensor may be stored without any special provisions. Place the sensor inside a bag to keep the sensor clean and store on a shelf or hang it on a wall.

d. When you read a barometer the reading directly from it is the "station pressure."

Two things affect the barometer's reading, the high or low air pressure caused by weather systems, and the air pressure caused by the station's elevation, or how high it is above sea level. No matter what weather systems are doing, the air's pressure decreases with height. If you're trying to draw a weather map of air pressure patterns, you need a way to remove the effects of the station's elevation. That is, you want to see what the pressure would be at the station if it were at sea level.

You need to calculate, sea-level pressure, which is defined as: "A pressure value obtained by the theoretical reduction of barometric

Global Water WE570 - Barometric Pressure Sensor - 1

Global Water

800-876-1172 • globalw.com

pressure to sea level. Where the Earth's surface is above sea level, it is assumed that the atmosphere extends to sea level below the station and that the properties of that hypothetical atmosphere are related to conditions observed at the station." To do this, you have to take into account the barometric reading at the station, the elevation above sea level, and the temperature.

Global Water WE570 - Global Water - 1

Global Water

800-876-1172 • globalw.com

V. Solar Radiation Sensor

a. Solar Radiation sensor specifications.

Output: 4-20mA

Range: 0-3000 Wm 2

Accuracy: 1% of full scale

Operating Voltage: 10-36VDC

Current Draw: Same as sensor output

Warm Up Time: 3 seconds minimum

Operating Temperature: -40°C to +55°C

Size of Probe: 3" diameter x 1 1/2" high

Weight: 1/4 lb.

b. The sensor is a two-wire sensor using the red wire for power and the black wire for the output signal. Warning: Always connect the sensor with the power turned off.

c. Ensure that the sensor is placed on a level surface, use the alignment bolts to adjust the sensor until it is level. Remove the red cap to begin taking readings.

d. The solar radiation sensor or pyranometer is an instrument for measuring solar radiation received from a whole hemisphere. It is suitable for measuring global sun plus sky radiation. Solar radiation varies significantly among regions. Season and time of day are major considerations, but surrounding terrain elevation, man-made obstructions, and surrounding trees can also cause large variations in locations with a small area. Often, the required measurement is, energy flux density of both direct beam and diffuse sky radiation passing through a horizontal plane of known unit area (i.e., global sun plus sky radiation).

e. Calibration should be confirmed annually.

Global Water WE570 - Solar Radiation Sensor - 1

Global Water

800-876-1172 • globalw.com

VI. Wind Speed Sensor

a. Wind Speed sensor specifications.

Output: 4-20mA

Range: 0-110 MPH

Accuracy: .2 MPH over the range 11 to 55 MPH

Operating Voltage: 10-36VDC

Current Draw: Same as sensor output

Warm Up Time: 3 seconds minimum

Operating Temp: -40° to +55° C

Size of Probe: 7" diameter x 8 1/2" long

Weight: 1 lb.

b. The sensor is a two-wire sensor using the red wire for power and the black wire for the output signal. Warning: Always connect the sensor with the power turned off.

c. The sensor comes with a stainless steel elbow that can be mounted on a 1" diameter tube. For best results ensure that the sensor is mounted parallel to the ground surface.

d. The wind speed sensor or anemometer produces a sine wave voltage signal with a frequency that changes linearly with the wind speed. The frequency is transformed into a 4-20 mA sensor signal output.

Global Water WE570 - Wind Speed Sensor - 1

Global Water

800-876-1172 • globalw.com

VII. Wind Direction Sensor

a. Wind Direction sensor specifications.

Output: 4-19 mA

Range: 0 to 360° (352° electrical, 8° open)

Accuracy: 1% of full scale

Operating Voltage: 10-36VDC

Current Draw: Same as sensor output

Warm Up Time: 3 seconds minimum

Operating Temp: -40° to +55° C

Size: 8 1/2 " diameter x 10 1/2 " long

Weight: 1 lb.

b. The sensor is a two-wire sensor using the red wire for power and the black wire for the output signal. Warning: Always connect the sensor with the power turned off.

c. The ridge on the fixed portion of the sensor represents the 0° direction of the sensor. The sensor comes with a stainless steel elbow that can be mounted on a 1" diameter tube. For best results ensure that the sensor is mounted parallel to the ground surface.

d. A wind direction sensor produces a ratiometric voltage signal. That voltage signal is transformed into a 4-19 mA sensor output signal.

Global Water WE570 - Wind Direction Sensor - 1

Global Water

800-876-1172 • globalw.com

VIII. Humidity Sensor

a. Humidity sensor specifications.

Output: 4-19mA

Range: 0-100% RH

Accuracy: + 2% RH

Operating Voltage: 10-36VDC

Current Draw: 3 mA plus sensor

Warm Up Time: 3 seconds minimum

Operating Temp: -40° to +55° C

Size of Probe: 1 ½" diameter x 7" long

Weight: 1/2 lb.

b. The humidity sensor is a three-wire sensor. Three wire sensors use the red wire for positive voltage, the white wire for the output signal, and the black wire for ground. Warning: Always connect the sensor with the power turned off.

c. Do not install the humidity sensor in direct sunlight.

d. A humidity sensor utilizes a thin polymer that varies in dielectric constant directly proportional to changes in the amount of water vapor at the sensor element. The element provides a linear voltage output that is converted into a 4-19 mA sensor output signal.

Global Water WE570 - Humidity Sensor - 1

Global Water

800-876-1172 • globalw.com

IX. Temperature Sensor

a. Temperature sensor specifications.

Output: 4-19mA

Range: -50° C to +50° C

Accuracy: ±0.2° F or ±0.1° C

Operating Voltage: 10-36VDC

Current Draw: Same as sensor output

Warm Up Time: 5 seconds minimum

Operating Temperature: -50°C to +100°C

Size of Probe: 3/4 " diameter x 4 1/2 " long

Weight: 1/2 lb.

b. The sensor is a two-wire sensor using the red wire for power and the black wire for the output signal. Warning: Always connect the sensor with the power turned off.

c. Do not install the temperature sensor in direct sunlight.

d. To check the temperature sensor calibration you will need:

1 thermometer

3 containers of water

1 power supply

1 current meter

Connecting wires as necessary

Connect the sensor to the power supply and current meter in the following way. Attach the black wire to the positive input of the current meter. Connect the ground terminal of the power supply to the ground of the current meter. Attach the red wire to the positive terminal of the power supply. Warning: Always connect the sensor with the power turned off.

See Appendix A for the temperature calibration worksheet.

Global Water WE570 - Temperature Sensor - 1

Global Water

800-876-1172 • globalw.com

X. Solar Shield

a. Solar Shield specifications.

Size:

4" diameter x 8 ½" long

Weight: 1 lb.

b. The solar shield is used to protect sensors, typically humidity and temperature, from direct sunlight. Insert a sensor into one of the two holes located on the underside of the shield. The shield provides a friction lock so the sensors will not accidentally fall out. The sensors can be removed by firmly twisting and pulling them out of the solar shield.

c. The shield comes with a stainless steel elbow that can be mounted on a 1" diameter tube. For best results ensure that the shield is mounted vertically.

XI. Maintenance

a. Global Water recommends confirming the calibration annually.

b. The sensors should be cleaned periodically. Sensors can be cleaned using a damp cotton cloth. NOTE: DO NOT submerge sensors. The sensors are water resistant, not water proof.

Global Water WE570 - Maintenance - 1

Global Water

800-876-1172 • globalw.com

XII. Trouble Shooting

Issue: Sensor reading incorrectly

a. Verify power source is supplying correct voltage.
b. Clean the sensor.
c. Confirm the sensor's calibration.

Other issues

d. Call Global Water for tech support: 800-876-1172 or 979-690-5560 (many problems can be solved over the phone). Fax: 979-690-0440 or Email: globalw@globalw.com.

When calling for tech support, please have the following information ready;

  1. Model #.
  2. Unit serial number.
  3. P.O.# the equipment was purchased on.
  4. Our sales number or the invoice number.
  5. Repair instructions and/or specific problems relating to the product.

Be prepared to describe the problem you are experiencing including specific details of the application, installation, and any additional pertinent information.

e. In the event that the equipment needs to be returned to the factory for any reason, please call to obtain an RMA# (Return Material Authorization). Do not return items without an RMA# displayed on the outside of the package.

Clean and decontaminate the sensor if necessary.

Include a written statement describing the problems.

Global Water WE570 - Other issues - 1

Global Water

800-876-1172 • globalw.com

Send the package with shipping prepaid to our factory address. Insure your shipment, Global Water's warranty does not cover damage incurred during transit.

Global Water WE570 - Global Water - 1

Global Water

800-876-1172 • globalw.com

XIII. Warranty

a. Global Water Instrumentation, Inc. warrants that its products are free from defects in material and workmanship under normal use and service for a period of one year from date of shipment from factory.
Global Water's obligations under this warranty are limited to, at Global Water's option: (I) replacing or (II) repairing; any products determined to be defective. In no case shall Global Water's liability exceed the products original purchase price. This warranty does not apply to any equipment that has been repaired or altered, except by Global Water Instrumentation, Inc., or which has been subject to misuse, negligence or accident. It is expressly agreed that this warranty will be in lieu of all warranties of fitness and in lieu of the warranty of merchantability.

b. The warranty begins on the date of your invoice.

Global Water WE570 - Warranty - 1

Global Water

800-876-1172 • globalw.com

XIV. Appendix A: Temperature Calibration check

Step 1) Fill a container of water with enough ice that it will not melt quickly.

Step 2) Place the temperature sensor and thermometer into the container. Turn on the power supply and the current meter. Let the sensor stabilize for 30 minutes before taking any measurements.

Step 3) Record the ice bath temperature, Iτ = ____, and record the output current of the sensor, IC = ____.

Step 4) Fill a container with enough warm water that it will not cool down quickly.

Step 5) Place the temperature sensor and thermometer into the container. Turn on the power supply and the current meter. Let the sensor stabilize for 30 minutes before taking any measurements.

Step 6) Record the warm water temperature, WT = , and record the output current of the sensor, WC = .

Step 7) Subtract I C from W C , W C- I C = ____ = C.

Step 8) Subtract I T from W T ,W T -I T = ____ = T.

Step 9) Calculate B. W c - (C/T)(W_T) = ____ = B.

Step 10) Find the low current value for the sensor. -(C/T)(50)+B= ____ = Lc . This current is the output current the sensor would produce if the temperature were -50°C .

Step 11) Find the high current value for the sensor. (C/T)(50)+B= ____ = Hc. This current is the output current the sensor would produce if the temperature were 50°C.

Step 12) Use these new current values to recalibrate the system that is monitoring the sensor output.

Global Water WE570 - Appendix A: Temperature Calibration check - 1

Global Water

800-876-1172 • globalw.com

XV. Appendix B: 2 Wire Sensor Measurement Diagram
Global Water Sensors Samplers Systems 11257 Coloma Rd. Cold River,Co USA (916) 538-3428 FAX (916) 538-3270 B C D 2 Wire Current Diagram The output of the sensor is current and has to be read with the multimeter in current mode. 4.00 200mA USA COM 200MA V Red +12V Black 2 Wire Voltage Diagram In orde…

Global Water WE570 - Global Water - 2

Global Water

800-876-1172 • globalw.com

XVI. Appendix C: 3 Wire Sensor Measurement Diagram
Global Water Sensors Samplers Systems 11267 Coloma Rd. Cold River,Ca USA (916) 038-3429 FAX (916) 038-3270 B C D 3 Wire Current Diagram The output of the sensor is current and has to be read with the multimeter in current mode. 4.00 200mA U/A COR 200mA V Red +12V Black White 3 Wire Voltage Diagram I…

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Global Water

Model : WE570

Category : Weather Station