| Product Type | Uninterruptible Power Supply (UPS) |
| Model | APC Connect BGE70 |
| Power Capacity | 700 VA / 400 W |
| Input Voltage | 230 V AC |
| Output Voltage | 230 V AC ± 10% |
| Frequency | 50/60 Hz (auto sensing) |
| Number of Outlets | 8 (5 surge protected, 3 surge + battery backup) |
| Battery Type | Lead-acid, sealed, maintenance-free |
| Battery Capacity | 12 V, 7 Ah |
| Typical Backup Time | 10 min at half load, 3 min at full load |
| Recharge Time | Approximately 8 hours |
| Surge Protection | 390 Joules |
| Dimensions (H x W x D) | 245 x 110 x 320 mm (9.6 x 4.3 x 12.6 in) |
| Weight | 7.5 kg (16.5 lbs) |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Relative Humidity | 0% to 95% non-condensing |
| Noise Level | 45 dBA at 1 m |
| Protection Features | Overload, short circuit, deep discharge protection |
| Maintenance | No user-serviceable parts; battery replacement only by qualified personnel |
| Safety Compliance | CE, EN 62040, IEC 62040 |
Frequently Asked Questions - Connect BGE70 APC
How do I replace the battery in my APC Connect BGE70?
To replace the battery, unplug the UPS and disconnect all devices. Remove the front bezel, disconnect the battery connector, slide out the old battery, and insert a new APC RBC2 or compatible battery. Reconnect and reassemble. Refer to the manual for detailed steps.
Why is my UPS beeping continuously?
Continuous beeping usually indicates a low battery or overload condition. Check if the battery is fully charged and not expired. Reduce the load by unplugging non-essential devices. If beeping persists, the battery may need replacement.
Can I connect a laser printer to the UPS?
It is not recommended to connect laser printers to the UPS due to their high power draw during warm-up. They should be plugged into a surge protector outlet only.
What does the 'replace battery' light mean?
The replace battery indicator lights up when the battery has reached the end of its service life. Replace the battery as soon as possible to ensure backup protection.
How long does the battery last before replacement?
Under normal conditions, the battery lasts about 3-5 years. Factors like temperature and usage affect lifespan. Regular self-tests help monitor battery health.
Is the UPS compatible with a generator?
Yes, but the generator must provide stable voltage and frequency (50/60 Hz) within the UPS input range. Some generator waveforms may cause the UPS to switch to battery. Use a sine-wave generator for best performance.
Can I charge the battery while the UPS is off?
The UPS will not charge the battery when it is switched off. To charge, turn the UPS on while connected to AC power. The battery charges automatically.
What is the maximum load I can connect?
The maximum load is 700 VA or 400 W. Exceeding this may cause the UPS to overload and shut down or beep continuously.
How do I perform a self-test?
Press and hold the power button for 3-5 seconds. The UPS will run a self-test, simulating a power loss. The test helps verify battery and inverter health.
Does the UPS protect against surges on the phone line?
Yes, the APC Connect BGE70 includes surge protection for a phone line (RJ11 jack). Connect your modem or phone line through the UPS for added protection.