Product Type Arc Fault Detection Device (AFDD)
Model AC-AFDDC-013
Brand Mach Power
Rated Voltage 230 V AC, 50/60 Hz
Rated Current 13 A
Number of Poles 1P + N
Arc Fault Protection Series and parallel arc detection
Overcurrent Protection Yes, thermal-magnetic
Short Circuit Protection Yes, up to 6 kA
Dimensions (H x W x D) 85 x 18 x 65 mm (2 modules)
Weight Approx. 100 g
Mounting DIN rail (35 mm)
Operating Temperature -25°C to +55°C
Storage Temperature -40°C to +70°C
Protection Degree IP20 (front panel)
Indicators LED for power, arc fault, and trip status
Test Button Yes, for functional test
Reset Function Manual reset after trip
Standards Compliance IEC 62606, EN 62606
Wire Capacity 1.5 to 25 mm² (solid/stranded)
Torque Setting 2.5 Nm
Maintenance Monthly test recommended; clean with dry cloth
Safety Features Arc fault detection, overcurrent, short circuit, lockable handle
Repairability Replaceable unit; no user-serviceable parts

Frequently Asked Questions - AC-AFDDC-013 Mach Power

What is an AFDD and what does the AC-AFDDC-013 do?
An AFDD (Arc Fault Detection Device) is a safety device that detects dangerous electrical arcs and disconnects the circuit to prevent fires. The Mach Power AC-AFDDC-013 is designed to detect both series and parallel arcs and provides combined overcurrent protection.
How do I install the AC-AFDDC-013?
Install it on a 35 mm DIN rail inside a distribution board. Ensure the power is off. Connect the phase and neutral wires according to the wiring diagram on the device. Tighten terminals to the specified torque (2.5 Nm). It occupies 2 modular spaces.
What is the rated current and voltage?
The rated voltage is 230 V AC (50/60 Hz) and the rated current is 13 A. It is suitable for single-phase circuits.
How do I test the AFDD?
Press the 'Test' button on the front panel. The device should trip and the LED will indicate. After testing, reset by moving the handle to 'ON'. Perform this test monthly to ensure proper operation.
What should I do if the device trips frequently?
Frequent tripping may indicate a real arc fault or an overload. Check for loose connections, damaged wiring, or faulty appliances. Use the Reset button to re-energize once the issue is resolved. If it persists, consult a qualified electrician.
Can I use the AC-AFDDC-013 in a three-phase system?
No, the AC-AFDDC-013 is a single-pole + neutral device designed for single-phase systems only. For three-phase applications, you would need three separate devices or a three-phase AFDD.
What wire sizes can I use?
The terminals accept solid or stranded wires from 1.5 mm² to 25 mm². Strip length 14 mm. Always ensure proper tightening.
Is the AC-AFDDC-013 compatible with smart home systems?
The device is a standalone protection unit without communication interfaces. It can be used in smart circuits but does not integrate directly with home automation systems.
What standards does this device comply with?
It complies with IEC 62606 and EN 62606 for arc fault detection devices, ensuring safety and performance requirements are met.
How should I clean and maintain the AFDD?
Disconnect power before cleaning. Wipe the housing with a dry, soft cloth. Do not use water or solvents. Periodically check for dust accumulation and test monthly.

User questions about AC-AFDDC-013 Mach Power

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Automatic barrier in PDF format for free! Find your manual AC-AFDDC-013 - Mach Power and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AC-AFDDC-013 by Mach Power.

USER MANUAL AC-AFDDC-013 Mach Power

natural_image Simple line drawing of a cabinet or cabinet with vertical lines and a curved panel, no text or symbols present.

Mach Power AC-AFDDC-013 - 1

natural_image Simple line drawing of a curved object with horizontal and vertical lines, no text or symbols present

EN

User Manual

AUTOMATIC FLAP DOOR GATE

ITA

Manuale d'uso

VARCO AUTOMATICO FLAP DOOR

ES

Manual de usuario

Installation instruction 5

Debug method instruction 6

Menu introduction 6

Main board Parameter 7

Turnstile wiring diagram 8

Product introduction

1. Equipment introduction

1.1 Category

Single core: used in single lane

Double cores: used in multi-lanes

2. Main function and characteristics

2.1 Function of standard product

  1. With function of self-examine and alarm, it is convenient for maintenance and use.
  2. Being able to program running status by the small keyboard in the main board
  3. Preventing pedestrians or bicycle from being nipped and from hurt
  4. Sound or light alarm function
  5. Poles are automatically locked until a opening signal is received.
  6. Poles synchronization
  7. Automatically reset function: It will automatically lock if the pedestrian hasn't pass through the channel in the pre-set time after the opening. The passing time is adjustable.
  8. Channels automatically open when power off, and automatically close when power on.
  9. Several card reading devices are attachable.
  10. One direction or bi-direction control are optional.
  11. It can be directly controlled and managed by remote control.

3. Standard technical parameters

Framework material 304/316 grade stainless steel
Framework size 1200(L) x 300(W) x 1000(H) mm
Length of the arms 260 mm
Working voltage AC220 ±10% V/50 ±10% Hz
Driving electromotor DC brush electromotor 24V
Input interface Dry contact signal or +12V level signal driving current: >10mA
Normal life-span 5 million times
Communication interface RS485 (standard)
Transit speed 30-40 persons/min
Card reader windows 4
Maintenance windows 4
Time for opening or closing 1 seconds
Starting time after power on 3 seconds
Working environment Indoor, outdoor( with a tent over)
Temperature -10°C ~ 50°C
Relative humidity ≤90% no condensation

Installation instruction

1. Installation on the ground

First of all, earthwork, a concrete base foot of 200mm height for anti-humidity (hereinafter called Safe island) should be built. Then, power cable of 220V3 x 1.5mm and two 4 x 0.5mm (12 cores) control cables should be laid under the middle of the casework. Fix the mechanism on the safe island. Connect it with power of 220V and control cable should be linked to control room.

link cable 220V power cable link cable 220V power cable

2. Important notices

  1. Without permission, please do not install any devices on the casework. Make sure devices earthing is reliable and devices are in the condition of safety and reliability.
  2. When the devices are used in the open air, they should be install on cement podium of 100mm---200mm height so as to avoid moisture; At the same time, build a tent over the devices to keep from rain. Directly installation in the open air is strictly prohibited.

Debug method instruction

  1. Connect main board with power, screen show "Flap barrier(swing barrier or double swing barrier), In counter and out counter number
  2. LCD screen have 5 button :Menu ,UP ,Down ,Enter and ESC
  3. Main board have RS485 port, can send turnstile gate command by RS485 port
  4. Press menu button to input password, password is press "UP" "UP" "DOWN" DOWN "UP" DOWN
  1. Direction Config, Left in Right out, Left out Right in
  2. Traffic control, L ban R enable, L enable R ban, All ban, All Enable
  3. Working mode, L infrared R card, L card R infrared, All infrared, All card
  4. Memory Func Config, L ban R enable, L enable R ban, All ban, All Enable
  5. Open time, Number is optional
  6. Counter reset
  7. Machine NO
  8. Machine Info
  9. Machine type, Flap barrier, Swing barrier, Double swing barrier
  10. System Ini, "will clear all info"
  11. Left Audio
  12. Right Audio
  13. Motor Speed, Master motor, Client motor
  14. Motor Max turn len
  15. Allowed Infrared over

  16. Delay Closing time

  17. Swing barrier Dire, Open-left, Open-right
  18. Break-in Operation, No close, Closed
  19. Motor brake, Close, Open
  20. Machine L-open set, UP+1 Down -1
  21. Other option
  22. Machine test

Main board Parameter

Brush motor flap barrier(swing barrier)main board parameter
Basic introductionInput power Voltage DC24VCurrent4.5A
Working temperature -15°C ~ 60°C
Working humidity ≤80%
Main board consumption <2W
IP IP52
Input terminal introductionSwitch power supplyVoltage DC18V ~ 26VCurrent 3A ~ 6.5A
IR sensor signalVoltage DC2.5V ~ 24VCurrent 5mA ~ 20mA
Limit sensorVoltage DC2.5V ~ 24VCurrent 5mA ~ 20mA
Open signal, Fire signalDry contact signal or +12V level signal. driving current 5mA ~ 20mA
Battery 12V 1HA ~ 5HA
Serial port 485
Output terminal introductionVoice port 4Ω~8Ω 10W
Direction board port DC125mA~20mA
Motor port DC 24V <2A
Light port No
Clutch port No
Fire output port No

Turnstile wiring diagram

Flap barrier connection drawing
(AC) 220V (24V 4.5A) POWER SUPPLY BATTERY LINK CABLE MAIN PCB LCD L/R Open VDD OPE-R OPE-L 3 L/R OPEN

Remark: below 1, 2, 3 ned do cable connection

Indice

For any information and product updates

visit our website www.machpower.it

Mach Power ® is a registered trademark

All Right Reserved

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Mach Power

Model : AC-AFDDC-013

Category : Automatic barrier