SW351-KCG - Alarm system SWANN - Free user manual and instructions
Find the device manual for free SW351-KCG SWANN in PDF.
| Product Type | Magnetic Keypad Door Alarm |
| Model | SW351-KCG |
| Brand | Swann |
| Power Supply | 3 x Alkaline AAA batteries (4.5V DC) |
| Battery Life | Replace every 6 months (more often in Chime mode with frequent use) |
| Low Battery Indicator | LED flashes slowly on front unit |
| Modes | Alarm and Chime (selectable via Mode Switch inside battery compartment) |
| Passcode Protection | Yes, 4-digit numerical code |
| Arming Delay | 45 seconds after entering passcode |
| Alarm Duration | 30 seconds countdown after trigger; alarm sounds if not disarmed |
| Siren Volume | > 110 dB |
| Mounting | Alarm unit on door/window frame; magnetic trigger on door/window |
| Trigger Distance | Alarm triggers if magnetic arrows separate > 1/3" (8-10 mm) |
| Indoor Use Only | Yes, do not install outdoors |
| Warranty | 1 year from original purchase date |
Frequently Asked Questions - SW351-KCG SWANN
User questions about SW351-KCG SWANN
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Alarm system in PDF format for free! Find your manual SW351-KCG - SWANN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SW351-KCG by SWANN.
USER MANUAL SW351-KCG SWANN
Magnetic Keypad Door Alarm
SW351-KCG

Operating Instructions
IMPORTANT - Read Before Installing
- Do not install the alarm unit near devices which generate magnetic fields (such as microwaves).
Do not• install any the alarm unit in direct sunlight.
Use only alkaline batteries.
All components are for indoor use only.• Do not install outdoors.
Replace the batteries in the unit every six months.
- Test the alarm periodically (every 1 - 2 months and each time you change the batteries) to ensure it is working properly.
- This alarm system is designed to be, and acts as, a theft deterrent. This system, like any other, cannot offer complete protection for your home or business - it is simply an alarm system. Like all practical systems, it has limitations and it could be disabled by a skilled intruder. We suggest that you avoid relying solely on this magnetic switch alarm to protect your property, but use it as part of a comprehensive security solution. You can increase your level of protection through the use of high-quality locks, stronger doors, guards for your windows and a CCTV system and recording devices.
About the Alarm Unit
Congratulations on your purchase of this keypad controlled magnetic alarm from Swann! This simple but powerful stand-alone alarm unit can be used to secure almost any door or window you want.

Selecting Modes
The Mode Select Switch is located within the battery compartment.
Alarm Mode: When the alarm is tripped, a thirty second countdown will begin - the indicator LED on the front of the alarm unit will flash during this countdown. During this time, the alarm can be disarmed by entering your passcode. If the passcode is not entered, the alarm will sound at full volume.
Chime Mode: Each time the alarm is tripped, the alarm unit will chime, much like a doorbell. The alarm does not need to be armed.
Arming Delay
When you use your passcode to arm the system, it will enter an arming delay of forty-five seconds. The indicator LED will flash during this time, and the alarm cannot be tripped. This is intended to give you time to arm the alarm unit and leave the area.
Installation
The alarm unit should be mounted on a door or window frame, and the magnetic trigger should be mounted on the door or window itself. When the door/window is closed, two black arrows (the one on the trigger and either one on the alarm unit) should be as close to touching as practicable.
To mount the alarm unit:
Attach the alarm unit using one of the provided screws - the mounting hole is in the • upper centre on the rear of the alarm unit.
Using the two smaller screws, attach the magnetic trigger to the door/window. Ensure that when the door or window is shut that the two black arrows are as close to touching as they can be. The alarm will be triggered if the arrows are moved more than approximately 1/3" (about 8-10mm) apart.
Setting your Passcode
Your passcode must be four digits long, and should be something that you will remember. Try to avoid obvious combinations (such as 1234 or similar).

Inside the Battery Compartment showing the Mode Switch and LEARN button.
To set your passcode:
Open the battery compartment and press the button labeled • LEARN.
Enter your four digit passcode. When entering the passcode, press buttons slowly and deliberately, waiting for the alarm unit to beep quickly to confirm each button press.
A louder, longer beep will confirm that a new passcode has been set.
Replacing Batteries
The batteries in the alarm unit should be replaced every six months. If you're using the sensor in chime mode and get a lot of visitors, you may need to change them more often.
Open the battery compartment and remove any batteries already installed.
Replace with three fresh alkaline AAA batteries. Do not mix battery types. Do not use • rechargeable batteries.
Low Battery Indicator
When the batteries in the alarm unit are running out, the LED on the front of the alarm unit will flash slowly (more slowly than during the arming delay). If the LED starts flashing in this way, change the batteries as soon as possible.
Technical Specifications
| General | Alarm Mode | ||
| Power Requirements 3 x Alkaline AAA Batteries (4.5V DC) | Passcode Protected Yes (4-digit numerical code) | ||
| Passcode Learning Duration 15s | |||
| Modes 2 (Alarm and Chime) | Siren Volume >110dB | ||
| Siren Duration 30s | |||
| Chime Mode | Entry Delay 30s | ||
| Chime Volume | >90dB | Exit Delay 45s | |
| Chime Duration | Approx. 2s | Re-Trigger Delay 5s | |
| Re-Trigger Delay | 5s | ||
Helpdesk / Technical Support Details
Swann Technical Support
All Countries E-mail: tech@swannsecurity.com
Telephone Helpdesk
USA toll free
1-800-627-2799
(Su, 2pm-10pm US PT)
(M-Th, 6am-10pm US PT)
(F 6am-2pm US PT)
USA Exchange & Repairs
I-800-627-2799 (Option I)
(M-F, 9am-5pm US PT)
AUSTRALIA toll free
1300 138 324
(M 9am-5pm AUS ET)
(Tu-F I am-5pm AUS ET)
(Sa I am-9am AUS ET)
NEW ZEALAND toll free
0800 479 266
UK
0203 027 0979
See http://www.worldtimeserver.com for information on time zones and the current time in Melbourne, Australia compared to your local time.
Warranty Information
Swann Communications USA Inc.
12636 Clark Street
Santa Fe Springs CA 90670
USA
Swann Communications
Unit 13, 331 Ingles Street,
Port Melbourne Vic 3207
Swann Communications LTD.
Stag Gates House
63/64 The Avenue
SO171XS
United Kingdom
Swann Communications warrants this product against defects in workmanship and material for a period of one (1) year from it's original purchase date. You must present your receipt as proof of date of purchase for warranty validation. Any unit which proves defective during the stated period will be repaired without charge for parts or labour or replaced at the sole discretion of Swann. The end user is responsible for all freight charges incurred to send the product to Swann's repair centres. The end user is responsible for all shipping costs incurred when shipping from and to any country other than the country of origin.
The warranty does not cover any incidental, accidental or consequential damages arising from the use of or the inability to use this product. Any costs associated with the fitting or removal of this product by a tradesman or other person or any other costs associated with its use are the responsibility of the end user. This warranty applies to the original purchaser of the product only and is not transferable to any third party. Unauthorized end user or third party modifications to any component or evidence of misuse or abuse of the device will render all warranties void.
By law some countries do not allow limitations on certain exclusions in this warranty.
Where applicable by local laws, regulations and legal rights will take precedence.