AAW-10CR1FHU - Air conditioner Admiral - Free user manual and instructions
Find the device manual for free AAW-10CR1FHU Admiral in PDF.
| Product Type | Portable Air Conditioner |
| Brand | Admiral |
| Model | AAW-10CR1FHU |
| Cooling Capacity | 10,000 BTU (ASHRAE) / 6,500 BTU (SACC) |
| Dimensions (W x H x D) | 22.0 x 17.5 x 13.5 in (55.9 x 44.5 x 34.3 cm) |
| Weight | 62.0 lb (28.1 kg) |
| Power Supply | 115 V ~ 60 Hz |
| Power Consumption (Cooling) | 950 W |
| Refrigerant | R-32 (32 g) |
| Modes | Cool, Fan, Dehumidify (Dry), Sleep, Auto |
| Fan Speeds | Low, Medium, High, Auto |
| Timer | 1-24 hour on/off timer |
| Remote Control | Included |
| Air Filter | Washable mesh filter |
| Maintenance | Clean filter every 2 weeks; drain condensate manually or via continuous drain |
| Safety Features | Auto shut-off on overheat, restart delay, child lock (via remote) |
| Installation | Includes window kit for vertical or horizontal sliding windows |
| Noise Level (Low/High) | 52 / 55 dBA |
| Energy Efficiency | EER: 8.5 CEER: 6.5 (estimated) |
| Spare Parts Availability | Filter, remote control, window kit components |
| Warranty | 1 year limited (parts and labor) |
Frequently Asked Questions - AAW-10CR1FHU Admiral
User questions about AAW-10CR1FHU Admiral
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air conditioner in PDF format for free! Find your manual AAW-10CR1FHU - Admiral and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AAW-10CR1FHU by Admiral.
USER MANUAL AAW-10CR1FHU Admiral
Mechanical control
Remote control
AAW-10CR1FHU
AAW-10DR3FHU
AAW-12CR1FHU
AAW-12DR3FHU
AAW-18CR3FHU
AAW-18DR3FHU
AAW-24CR3FHU
AAW-24DR3FHU

Table of Contents
Page
Introduction 2
Parts Identification 2
Electrical Specifications 4
Tips Before Installation 5
Installation Instructions 6
Operating Instructions 11
Care and Maintenance 15
Trouble Shooting Guide 16
Warranty 17
indice
Página
Introduzione 19
Introduction
Thank you for choosing this room air conditioner to cool your home. This USE AND CARE MANUAL provides information necessary for the proper care and maintenance of your new room air conditioner. If properly maintained, your air conditioner will give you many years of trouble free operation. To avoid installation difficulties, read instructions completely before starting. This manual contains information for the installation and operation of your room air conditioner.
Part Identification
▶ Mechanical control model

Introduction
Part Identification
▶ Remote control model

Electrical specifications
- All wiring must comply with local and national electrical codes and must be installed by a licenced electrician. If you have any questions regarding the following instructions, contact a licenced electrician.
- Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.
- For your safety and protection, this unit is grounded through the power cord when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a licenced electrician.
- The wall outlet (3-pin) must match the plug (3-pin) on the power cord supplied with the unit. DO NOT use plug adapters or extension cords. See (Table 1) for receptacle and fuse information.
- The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit. Make sure to use the correct power supply according to the rating plate of your air conditioner.

Electric Shock Hazard

If the air conditioner has a serial plate rating of 115 volts and up to and including 7.5 amps, the unit maybe on a fuse or circuit breaker with other devices. However, the maximum amps on all devices for that fuse or circuit breaker can not exceed the amps of the fuse for the circuit breaker.
If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.
If the air conditioner has a serial plate rating of 230 volts, it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.
To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.
Tips before installation
Your Room Air Conditioner unit is designed to be highly efficient and save energy. Follow these recommendations for greater efficiency.
- Select thermostat setting that suits your comfort needs and leave the thermostat at that chosen setting.
- The air filter is very efficient in removing airborne particles. Keep the air filter clean. Typically, the filter should be cleaned once a month. More frequent cleaning may be necessary depending on outdoor and indoor air quality.
- Use drapes, curtains, or shades to keep direct sunlight from heating your room, but DO NOT obstruct the air conditioner. Allow air to circulate around the unit without obstructions.
- Start your air conditioner before outdoor air becomes hot/cold and uncomfortable. This avoids an initial period of discomfort while the unit is cooling or heating off the room.
- When outdoor temperature is cool enough, use HIGH or LOW FAN only. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting.
CAUTION
To avoid installation/operating difficulties, read the instructions thoroughly.
NOTE: Save the shipping carton and packing materials for future storage or transport of the unit. Please check the contents of the hardware kit against the corresponding model check list, prior to installation of the unit. See lists below.(Fig.A)
Fig. A Installation Hardware

3/4*Screws (10)

1/4*Screws (23)

Top Channel(1)

Bottom Channel(1)

Bottom Channel(1)
(For 18K to 24K models -Factory installed)

Lock Washers(4)

1-1/2"x1/4 Bolts(4)

1/4" Nuts(4)

Shutter Clamp(2)

Washer(10)
Installation instructions

CAUTION

Because the compressor is located on the controls side of the unit (right side), this side will be heavier and more awkward to manipulate. Inadequate support on control side of the unit can result in personal injury and damage to your unit and property. Therefore, it is recommended to have someone assist you during the installation of this unit.
E. Be certain the proper electrical outlet is within reach of the installation. Use only a single outlet circuit rated at proper current (see table 1 on page 4). All wiring should be in accordance with local and national electrical codes.
F. Your unit was designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess condensation may cause the basepan to overflow to the outside. The unit should be installed where condensation run-off cannot drip on pedestrians or neighboring properties.
1. Select the Best Location
A. Your room air conditioner was designed to fit easily into a single or double hung window. However, since window designs vary, it may be necessary to make some modifications for safe and proper installation.
B. Make sure window and frame is structurally sound and free from dry and rotted wood.
C. For maximum efficiency, install the air conditioner on side of the house or building which favors more shade than sunlight. If the unit is in direct sunlight, it is advisable to provide an awning over the unit

Installation instructions
2. Preparation to Remove the Air Conditioner Slide-Out Chassis
A. Remove total of (4) Philips screws securing the chassis to the cabinet. There are (2) screws on each side. The set of screws closest to the front of the unit secure the front panel to the cabinet. The set of screw closest to the rear of the unit secure the cabinet to the chassis. See (Fig. 1).
B. Remove the front panel assembly from the cabinet by gently pulling it.
C. Grasp the pull handle at the front of the slide-out chassis and carefully slide the air conditioner out of the cabinet. See (Fig. 2).
Please seek assistance for this procedure.
NOTE: Screws must be reinstalled upon completion of the window installation to secure slide-out chassis.
- Assembly of the upper & lower channels to the cabinet

Fig. 1

Fig. 2

Installation instructions
5. Installation of Mounting Brackets and First Sealing Strip
NOTE: Windows come in a variety of different styles. Therefore, it may be necessary to modify or improve your particular installation.
A. Attach the bracket assembly to 90° angle support brackets (Fig. 5) using (2) 1 1/2" bolts
Two bolts per bracket. Secure with the (2) 1/4" lock washers and (2) 1/4"nuts. DO NOT immediately tighten these bolts as it may be necessary to adjust the depth of the bracket assembly, depending on the depth of your window sill. See (Fig. 7). Install the two leveling screws into the 90° support brackets. Test the bracket assembly in the window before cabinet installation. If the leveling screws are distanced too far away from the wall to provide stability, it may be necessary for you to fill this area with a solid piece of wood. See (Fig. 8).
B. Measure the inside window sill width and find the center as shown in (Fig. 6). Align the V-slot in each bracket on these marks and mount the brackets to the sill using 3/4" screws provided. Brackets should be perpendicular to the inside window sill. See (Fig. 6).
![graph TD A["V-akt"] --> B["(TOP VIEW)"] B --> C["Bracket Assembly"] B --> D["Bracket Solts"] B --> E["Leveling Screw"] C --> F["BIT Angle Support Brackets"] D --> F E --> F](/content/2026/05/924957/images/3d5798fd518e8b57a629bd13a6204044841e1523f8ac332011a11570f99306d7.jpg)
Fig. 5

Fig. 6

Installation instructions
6. Installation of the cabinet
A. Align one hole in the bottom of the cabinet with one hole in the bracket assembly. Secure the cabinet to the bracket using (3) 1/4" screws provided. Repeat the same procedure on the opposite side of the cabinet. See (Fig. 10).
B. Ensure the "L" shaped mounting channel is positioned in front of the sash. The bottom channel of the cabinet should be positioned in the track provided on the bracket assembly. Pull the window down until it rests just behind the front of the "L" shaped mounting channel. See (Fig. 11).
C. Check to make sure that the cabinet is slanted slightly downward on the outside. If necessary, re-adjust support bracket as shown in (Fig. 7).
7. Secure Shutters
A. Carefully slide the air conditioner back into the cabinet.(Please seek assistance for this procedure). B. Reinstall the slide-out-chassis security screws (removed earlier) on both sides of the cabinet. See (Fig. 12)

Fig. 10

Fig. 11
Installation instructions
9. Complete the installation
A. Cut the foam to fit the opening between the top of the inside and outside window. See (Fig. 13).
B. Some installations may require additional sealing around the window and air conditioner. Check for any air leaks and seal where necessary.
C. In very humid areas, the water removal may be excessive enough to overflow the unit or increase the noise of the air conditioner. If this occurs, you may wish to attach a drain hose (not included) to the drain plug allowing condensations to run off conveniently.
See (Fig. 14).

Fig. 13

Fig. 14
Operating Instructions
▶ Mechanical control model
MODE
The mode knob controls fan speeds and cooling speeds. To set desired cooling temperature, simply rotate the mode knob dial to the appropriate setting.
THERMOSTAT
The thermostat automatically controls the cooling cycle (compressor) of the air conditioner to maintain room temperature. However, the fan motor will continue to operate after the compressor (cooling cycle) is completed.
LOW FAN will circulate the air at a minimum speed without cooling.
MED FAN will circulate the air at a middle speed without cooling.
HIGH FAN will circulate the air at a maximum speed without cooling.
LOW COOL provides cooling, automatically with minimum air circulation. Recommended for night-time use.
MED COOL provides cooling, automatically with middle air circulation. Recommended for night-time use.
HIGH COOL provides cooling, automatically with quick cooling or for extremely hot days. Once room is cooled, reduce setting to LOW COOL.

Fig. 15

Operating Instructions
▶ Electronic control panel model
You can easily operate this air conditioner by pressing relevant button on the control panel as well as the remote control.

Button
The air conditioner will be started when it is energized or will be stopped when it is in operation, if you press this button. When the air conditioner is heating, allow 3 minutes after you press this button.
Mode button
Each time MODE button is pressed, the operation mode is changed in sequence:
COOL: COOLING FAN ONLY ENERGY SAVING → COOLING
HEAT: COOLING-FAN ONLY HEATING ENERGY SAVING COOLING
NOTE: After setting the mode, allow 3 minutes before switching to another mode.
In the FAN ONLY Mode, Room Temperature display range is from 0 (32) fb 38 (99°C) °F
Room Temperature below 32 th the Temperature display L0. Room Temperature above 99 th the Temperature display H1.
Fan Speed button
Used to select fan speed in sequence auto, low, medium and high.
Timer button
Control Panel

Indication symbols of LED on control panel:
Above LED lights on when the relevant mode is in used.
Operating Instructions
▶ Remote control

1 Power BUTTON
The appliance will be started when it is energized or will be stopped when it is in operation, if you press this button.
2 Mode BUTTON
Used to select the operation mode.
3 + BUTTONS
Used to set room temperature in Cooling mode or used to set time in Timer mode.
4 High BUTTON
Used to select the mode.high fan speed
5 Mid BUTTON
Used to select the Mid mode.fan speed
6 Low BUTTON
Used to select the Low mode.fan speed
7 Auto BUTTON
Used to select the Auto mode. fan speed
Timer BUTTON
Operating Instructions
▶ Remote control
• How to Insert the Batteries
Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly.
Reattach the cover by sliding it back into position.
Note:
- Use 2 LR06 AA(1.5volt) batteries. Do not use rechargeable batteries. Replace batteries with new ones of the same type when the display becomes dim.
* If the replacement is done within 1 minute, the remote control will keep original presetting. (This function only for LCD remote control)
• How to Use
To operate the room air conditioner, aim the remote control to the signal receptor. The remote control will operate the air conditioner at a distance of up to 23 feet when pointing at signal receptor of unit.


Care and Maintenance
When servicing the air conditioner, be sure to turn the mode switch to the "OFF" position and disconnect the power cord from the electrical outlet.
- DO NOT use gasoline, benzine, thinner or other chemicals on the air conditioner as these substances may cause damage to the paint finish and deformation of plastic parts.
- Never attempt to pour water directly in front of the unit as this will cause deterioration of the electrical insulation.
Cleaning the Air Filter
Removal of Air Filter
If the air filter becomes clogged with dust, air-flow is obstructed and reduces efficiency. The air filter should be cleaned once a month. More frequent cleaning may be necessary depending on outdoor and indoor air quality.
Air Filter Removal:
The air filter on the above model is located behind the air intake front grill.
To remove the air filter, open the air inlet grille and
CAUTION
DO NOT forget to install the air filter. If the air conditioner is left to operate without the air filter, dust is not removed from the room and may cause your air conditioner to fail.
When the air filter inlet grill and cabinet are dirty, wipe with lukewarm water (below 40° C/104°F). Use of mild detergent is recommended.
Cleaning of Air Filter
- Remove dust clogged in the filter by tapping it or vacuum clean it.
- Wash the filter well with lukewarm water below 40° C ( 104° F) while rubbing lightly: To get better results, wash it with soapy water or a neutral cleaning agent.
- Rinse the filter well using clean water then dry completely.
End-of-Season Care
- Operate the fan alone for half a day to dry out
Troubleshooting Guide
Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a possible solution.
| PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION | ||
| Air conditioner will not operate | No power to the unit. | Check connection of power cord to power source.Check fuse or circuit breaker.Set FAN CONTROL to position other than "OFF". |
| Inefficient or no cooling | Dirty air filter.Inappropriate capacity for application.Blocked air flow.Power interruption, settings change too quickly, or compressor overload tripped. | Clean or replace air filter.Check with dealer to determine proper unit capacity for application.Remove obstruction from grill or outdoor louvers.Let fan run to restart compressor (in approximately 10 minutes). |
| Noisy unit | Loose parts.Inadequate support. | Tighten loose parts.Provide additional support to unit. |
| Odors | Formation of mold, mildew, or algae on wet surfaces. | Remove drain plug and drain base pan.Replace drain plug. |
Warranty
5 YEAR FULL WARRANTY
This product is warranted for 5 years from the date of original purchase. Any part which fails in materials or workmanship will be replaced within the warranty period. This warranty covers in home service. A copy of your proof of purchase, with date of purchase and product name included, is required to arrange this service repair.
For the name and location of an authorized service provider nearest you, please CALL 1-877-465-3566. Please reference product name, brand name, and model number when you call.
This warranty does not apply if the damage occurs because of accident, improper handling or operation, shipping damage, abuse, misuse, unauthorized repairs made or attempted, or the use of the product for commercial use, or any other use for which it was not intended.
ALL WARRANTIES, EXPRESSED OR IMPLIED, LAST FOR 5 YEARS FROM THE DATE OF ORIGINAL PURCHASE. THIS WARRANTY DOES NOT COVER LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR ANY CAUSE WHATSOEVER.
This warranty is extended to the original owner and any succeeding owner for products purchased for home use within the USA. Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific rights, and you may also have other rights which may vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state's Attorney General.
Introducción