LMB10V - Steam stripper EARLEX - Free user manual and instructions
Find the device manual for free LMB10V EARLEX in PDF.
| Product Type | Steam Wallpaper Stripper |
| Model | LMB10V (also LMB230V / LMB110V) |
| Voltage | 230V or 110V (model dependent) |
| Power Consumption | Not specified; estimated ~1500–2000 W |
| Water Tank Capacity | Approximately 3–4 liters (based on runtime) |
| Operating Runtime | Up to 1.5 hours (230V) / up to 3.25 hours (110V) |
| Steam Temperature | 100°C (212°F) |
| Maximum User Weight | 127 kg (20 stone), 1 person only |
| Safety Features | Thermal cut-out, 4 lb pressure cap (safety valve), anti-boil dry protection |
| Hose Length | Not specified; estimated 2–3 m |
| Cord Length | Not specified; estimated 3–4 m |
| Materials | Metal tank with plastic frame and steam plate |
| Intended Use | Wallpaper removal, Artex® removal, vinyl tile lifting, soil sterilization, weed killing |
| Maintenance | Descale every 3 months with proprietary product; flush tank before storage |
| Spare Parts Availability | Full range from Earlex; same-day dispatch for credit accounts/cards |
| Warranty / Support | Helpline: +44 (0)1483 454666 (Mon–Fri 08:30–18:00) |
| Storage | Use built-in spools for hose and cord; steam plate clips onto frame |
| Weight (approx.) | Estimated 10–12 kg |
| Dimensions (approx.) | Estimated 40×30×45 cm (H×W×D) |
Frequently Asked Questions - LMB10V EARLEX
User questions about LMB10V EARLEX
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Steam stripper in PDF format for free! Find your manual LMB10V - EARLEX and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LMB10V by EARLEX.
USER MANUAL LMB10V EARLEX
Earlex® STEAMMASTER®
OPERATING INSTRUCTIONS
Models LMB230V/LMB110V

natural_image
Exterior view of a metal filing machine with a spool and control panel (no visible text or symbols)Safety Rules
- Keep away from children and animals.
- Do not pull by the mains lead or the steam hose.
- Be careful of overhead dripping, when using on overhead areas tilt the steam plate away from the face and body, and regularly empty the steamplate of any collected condensation.
- Do not leave unattended.
- Do not point the steam plate at anyone.
- Do not allow water or steam to enter light switches or sockets.
- Always use and store upright.
- Always visually check that the hose and steam plate inlet are not blocked before attempting to use.
- Do not strain, kink or trap the hose under heavy objects.
- Use only 4lb pressure cap as supplied. It is also a safety valve. NEVER BLOCK OFF THIS OUTLET.
- NEVER remove the filler cap when unit is boiling - switch off and wait for 5 minutes.
- Before standing on the frame ensure all screws are tight and the frame is undamaged.
-
Never use outside when raining.
-
Always disconnect power supply when filling the machine or when not in use.
- Do not use any caustic cleaners on the tank.
- Do not allow to boil dry.
- Do not overfill the reservoir. DO NOT USE ADDITIVES.
- Never detach the hose whilst the unit is switched on.
- The tank becomes hot in use. Do not touch. Only move with the carrying frame.
- Steam is produced at 100^ . Wear protective clothing and gloves when operating this stripper.
- When standing on the stripper always remain within the confines of the step and do not over-reach.
- DO NOT USE THIS STRIPPER FOR ANY OTHER PURPOSES THAN DETAILED IN THESE INSTRUCTIONS.
- Under no circumstances should you attempt to repair a unit unless qualified and authorised to do so. Use only genuine Earlex replacement parts.
• Maximum weight for standing on the unit is 127 kg (20 stone) and no more than 1 person at a time.
Preparation
To achieve fastest paper removal always gently score the areas to be stripped. With heavily embossed, vinyl coated or painted papers this is essential. Either use a proprietary perforator tool or alternatively score the paper with the edge of a wall scraper in a criss-cross pattern with 150mm (6 inch) spacing.
As with all decorating work be sure to protect carpets and furniture with covers.

natural_image
Illustration of a hand holding a trowel against a grid-patterned background (no text or symbols)Operation
STEAM IS HOT! The SteamMaster® is designed for safe, fast removal of wallpaper but you must be aware that steam is produced at 100°C so be careful, wear protective clothing and protect your hands with heat resistant gloves or mitts. Place the unit on a flat surface near to the area to be stripped. Remove the steam plate.
FULLY UNCOIL the hose and mains lead. Connect the thread on the steam plate to the end of the hose. This only needs to be hand tight. DO NOT OVERTIGHTEN.

lead from the unit to the socket and switch on. The mains switch on the unit has a neon light and will light when the unit is on. It will take between 10 and 20 minutes for the 230V unit or 25-35 minutes for the 110V unit to start producing steam depending on the temperature of the water used. DO NOT LEAVE UNATTENDED.
Once steam is being produced at the steam plate you are ready to commence operation. Prior to the steam being produced a small amount of bubbling will occur at the steam plate. WARNING: Beware of hot water discharge prior to steam emission. When the steam has been produced, lift the steam plate above the level of the tank outlet to allow condensed steam to run back down the hose and into the tank.
If you are right handed hold the steam plate in your left hand and place flat against the wall where you wish to commence removing.
Leave the plate against the wall for approximately 10 seconds. If you are left handed you may find it easier to operate with the other hand.
Move the steam plate to the section
The 230V unit will operate for approximately 1 1/2 hrs and the 110V unit will operate for approximately 3 1/4 hrs before requiring refilling. The water level is shown through the glass level indicator and should not be allowed to fall below minimum. Switch the unit off when this level has been reached. If you require further use of the steamer, ensure unit is switched off and has stopped boiling. Wait for 5 minutes. Slowly unscrew the cap, any remaining trapped steam will be released from beneath cap. Caution - steam is very hot - wear a glove and keep face clear. Refill to the level indicator as before and follow above instructions. YOU MUST NEVER ALLOW THE UNIT TO BOIL DRY.
There is a safety thermal cut-out device fitted to the unit. If the unit is allowed to boil dry this will operate and prevent further use. Switch the unit off and allow it to cool for at least 5 minutes, refill with water and then switch on again - the thermal cut-out should automatically re-set. If this has not re-set allow a further cooling period.
When you have finished using the unit allow any remaining water to cool and then empty the unit. We recommend flushing the tank out with clean water before storing. NEVER LEAVE WATER IN THE UNIT WHILST BEING STORED.
Storage Spools
These are designed for easy and compact storage. The mains lead and hose must be fully unwound before commencing to operate the unit.
Storage Steam Plate
The handle of the steam plate is shaped to locate between the frame and the tank. Slide the plate into position with the handle against the tank and the thread towards the base.

natural_image
Technical line drawing of a mechanical device with no visible text or symbolsFiller Cap
To fit - screw onto the filler neck hand tight. Do not overtighten.
To remove - ensure unit is switched off and has stopped boiling. Wait for 5 minutes. Slowly unscrew the cap, any remaining trapped steam will be released from beneath cap. Caution - steam is very hot - wear a glove and keep face clear. Refill to the level indicator as before and follow above instructions. DANGER FROM STEAM.
Other Uses
The SteamMaster® can also be used to:
- Remove Artex®.
- Lift stuck down vinyl tiles.
- Sterilise soil.
- Kill garden weeds.
TROUBLE SHOOTING
Unit Fails to Boil
- The thermal cut-out has operated. Switch off, allow to cool, refill with water then switch on again.
- Check the fuse in the plug - 230V unit only.
- If using an extension lead - check that the thermal re-set button on the extension lead has not tripped out. Check that the extension lead is rated at a minimum of 13 amps - 230V unit only.
If the unit still will not operate return the unit to the dealer or authorised agent to check the thermal fuse link and element. ONLY QUALIFIED ELECTRICIANS SHOULD UNDERTAKE THIS WORK.
Unit keeps cutting out
- Check that water is above minimum level.
- Check that the extension lead is rated at 13 amps minimum and fully unwound. 230V unit only.
- Check that no additives have been used.
Steam escaping from Filler Cap
- Check for blockages in hose or steam plate.
- Clean seating around cap area.
Descalling
We recommend that the tank is cleaned every three months using proprietary descaling products, used as per the manufacturers instructions.
Spare Parts
The full range of spare parts is available from Earlex. Despatch is available same day by first class post to Companies with credit facilities or for payment by credit card.
IF YOU REQUIRE ANY FURTHER ASSISTANCE PLEASE CALL OUR HELPLINE ON 01483 454666
Monday - Friday 08.30 - 18.00
(Excluding Bank Holidays)