Product Type Managed Gigabit PoE+ Switch
Model AMS-1816P
Brand Luxul
Ports 16 x 10/100/1000 PoE+ (802.3at/af) + 2 x Gigabit SFP
PoE Budget 250W
Switching Capacity 36 Gbps
Dimensions 17.3 x 9.5 x 1.7 inches (440 x 241 x 43 mm)
Weight 6.5 lbs (2.95 kg)
Power Supply Internal, 100-240V AC, 50-60Hz
Power Consumption Max 300W (including PoE)
Management Web GUI, CLI, SNMP v1/v2c/v3
VLAN Support 802.1Q VLAN (up to 256 groups)
Quality of Service 802.1p, DSCP, port-based QoS
Security 802.1X, ACL, SSH/SSL, port security
Operating Temperature 32°F to 113°F (0°C to 45°C)
Mounting 19-inch rackmount ears included
Maintenance Clean with dry cloth; no liquid cleaners
Repairability No user-serviceable parts; contact Luxul support
Warranty Limited lifetime warranty

Frequently Asked Questions - AMS-1816P Luxul

How to reset the Luxul AMS-1816P to factory defaults?
Press and hold the reset button on the front panel for 10 seconds using a paperclip. The device will reboot with factory settings.
What is the default IP address for management?
The default IP address is 192.168.1.50. Ensure your computer is on the same subnet to access the web interface.
Does the AMS-1816P support PoE passthrough?
No, it does not. It is a PoE source switch providing power to connected devices.
How can I update the firmware?
Download the latest firmware from Luxul's website, then upload it via the web interface under System > Firmware Upgrade.
Why are some PoE ports not powering my devices?
Check that the device is PoE compatible and that the total PoE budget is not exceeded. Also ensure the port is enabled for PoE in the settings.
What is the maximum cable length for twisted pair?
The maximum cable length for twisted pair connections is 100 meters (328 feet) as per Ethernet standards.
Can I use SFP modules for fiber connections?
Yes, the AMS-1816P has two SFP slots supporting 1G SFP modules. Use compatible modules from Luxul or standards-based SFP.
How to configure VLANs on this switch?
Use the web interface under Switching > VLAN. Create VLANs and assign ports as tagged or untagged. Port-based and 802.1Q are supported.
The fan is loud; is that normal?
The switch has variable-speed fans. Under high load or high temperature, fan speed increases. If persistently loud, check for obstructions or airflow.
Does this switch support SNMP?
Yes, it supports SNMP v1, v2c, and v3 for network monitoring and management. Configure SNMP under the Administration menu.

User questions about AMS-1816P Luxul

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Switch in PDF format for free! Find your manual AMS-1816P - Luxul and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AMS-1816P by Luxul.

USER MANUAL AMS-1816P Luxul

natural_image Exterior view of a black LUXUL device with indicator lights and a green screen (no readable text or symbols beyond branding)

18-Port Gigabit PoE+ L2 Managed Switch

AMS-1816P

Includes:

AMS-1816P 18-port/16-port PoE+ switch
Rack mount kit
Rubber feet
Power cord

INSTALLATION AND SETUP

1 Physical Installation

The AMS-1816P can easily be installed in a standard 19" rack. Two mounting ears are included for installing and stabilizing the switch. When attaching the mounting ears and installing the switch in a rack, please refer to the following illustration:

Luxul AMS-1816P - Physical Installation - 1

natural_image 3D diagram of an LUXUL device with labeled components and light rays, no readable text or symbols beyond brand logo

Rack-Mounting the AMS-1816P

▶Use the included screws to attach the mounting ears to each side of the switch.

Mount the switch in the rack with the LEDs facing outwards. Be sure the switch is level and properly secured in the rack.

Desktop Setup

For use as a desktop device, position and apply the included rubber feet to the bottom of the AMS-1816P.

2 Connecting Ethernet and Power

Ethernet and Power Connections

Use one of the 18 Ethernet ports to connect the AMS-1816P to any Ethernet enabled device, including control systems, routers, or other switches.

No crossover cable is necessary.

The AMS-1816P supports 10/100/1000 Mbps Ethernet, 10/100 Mbps half/full-duplex mode, and 1000 Mbps full-duplex mode. Ports 17 and 18 consist of two Gigabit RJ-45 uplink ports and 2 shared SFP combo ports; use only one of the Ethernet port or fiber port with the same-numbered ports at a time.

Use the included power cable to connect the AMS-1816P to a surge-protected outlet. The AC input socket is on the rear panel. The built-in power supply supports 100\~240VAC at 50/60Hz.

Network Cabling

Luxul recommends at least Cat-5e unshielded twisted pair (CAT5e UTP) cabling. To ensure best performance and stable data transmission at 1000 Mbps, use Category-6 unshielded twisted pair (CAT6 UTP).

Luxul AMS-1816P - Network Cabling - 1

CAUTION: Multiple Uplink channels can create loops, resulting in network failure. Ensure only one Uplink channel exists between switches or between the AMS-1816P and a router.

Luxul AMS-1816P - Network Cabling - 2

NOTE: When powering up, the port LEDs may take a moment to initialize. This is normal as the AMS-1816P initialization and startup sequence completes.

Luxul AMS-1816P - Network Cabling - 3

NOTE: The AMS-1816P has an internal 185W power supply. Do not exceed 185W combined consumption of all PoE devices.

Luxul AMS-1816P - Network Cabling - 4

Preparing for Access

IP Addressing

If the AMS-1816P is connected to a network with a 192.168.0.X/255.255.255.0 address scheme and your computer shares a similar address on the same network, you can skip to the next step, Access and Setup

Luxul AMS-1816P - IP Addressing - 1

Note: If another device on your network shares the 192.168.0.4 address, you'll need to temporarily reassign or remove that device while you configure the AMS-1816P.

If your network uses an address scheme other than 192.168.0.X, you'll need to set a temporary static IP address on the computer you're using for configuration. To do so, set the IP address of your computer to an address in the 192.168.0.X range, then set the Gateway/Router address to 192.168.0.4 (the default IP address of the AMS-1816P).

Once you're finished configuring the switch, you can return your computer's IP configuration to normal, typically "Obtain Automatically/DHCP."

Luxul AMS-1816P - IP Addressing - 2

Note: Visit http://luxul.com/ip-addressing to learn more about changing your computer's IP address and getting connected.

Luxul AMS-1816P - IP Addressing - 3

Access and Setup

Getting Connected

Use an Ethernet cable to connect your computer to the AMS-1816P, then power on the switch.

Logging In

To access the AMS-1816P web configuration, open your web browser and enter the switch's default 192.168.0.4 IP address in the address field. Log in to the switch using the default user name and password:

Default IP: 192.168.0.4

Username: admin

Password: admin

Select the menu items on the left to view and/or modify the configuration.

Refer to the Quick Setup Guide at Luxul.com for more detailed information on setup, IP configuration and routing, PoE, VLANs, and Spanning Tree.

Luxul AMS-1816P - Logging In - 1

Hardware Operation

Front Panel

The front panel of the AMS-1816P includes dual colored Link/Activity LEDs that can be switched from green to blue. In addition, the front panel has Link/Activity and PoE mode indicators as well as System and Power LEDs.

LUXUL LUXUL

AMS-1816P Front Panel View

Rear Panel

The rear panel of the AMS-1816P includes 1 console port, 16 1000Mbps RJ-45 and 2 RJ-45/SFP combo ports, as well as LED indicators for each port. Each 1000Mbps port has one Link/Activity/PoE LED. The Mode/Reset button switches the display between Link/Activity and PoE modes.

Luxul AMS-1816P - Rear Panel - 1

natural_image Front view of a network switch device with multiple ports and an external port (no visible text or labels)

AMS-1816P Back Panel View

LED Indicators

The LED indicators on the AMS-1816P include System, Link/Act and PoE LEDs, and an LED for each port. These LED indicators show the operating status of the AMS-1816P and each port connection.

Mode/Reset Button to Change LED Functionality

Briefly tapping the Mode/Reset button switches the port indicator between displaying port link speed and PoE status.

The following chart shows the LED indicators of the AMS-1816P along with an explanation of the indicators' properties:

Indicator NameDescription
SystemGreen Flashing Indicates normal operation
Green On Indicates a malfunction; contact support
Red OnIndicates power-on system initialization
OffIndicates startup/initialization process or that power is not on
Port Link/Act Status 1-18Green1000Mbps device connected to the port
Yellow10/100Mbps device connected to the port
FlashingPort receiving or transmitting data
OffNothing connected to the port
Port PoE Status 1-16GreenSwitch is providing PoE power to a device
YellowPoE is off due to a fault or because the connected device is exceeding power limit
OffPort disconnected or link failed

Note: At startup, the port LEDs will flash briefly during a self-test

Mode/Reset Button to Reset/Restore

The Reset button (located at the lower-left corner of the front panel) is used to reset (reboot) the switch or to restore the switch to factory default settings.

To Reboot/Reset the Switch: With the AMS-1816P powered on, press the Reset button for approximately three seconds until the Link/Act and PoE LEDs both light, then release the button.

Luxul AMS-1816P - Mode/Reset Button to Reset/Restore - 1

CAUTION: Holding the button between 3 and 8 seconds will erase all of the config except the IP address of the switch.

To Restore Default Settings: With the AMS-1816P powered on, press and hold the Reset button approximately eight seconds, until both the Link/Act and PoE LEDs turn off, then release the Reset button. The switch will automatically restore factory default settings and reboot. Once the System LED starts flashing again, the AMS-1816P is running with factory defaults.

Luxul AMS-1816P - Mode/Reset Button to Reset/Restore - 2

CAUTION: Please note that restoring Default Settings will remove any/all custom configuration.

Sales

801-822-5450

sales@luxul.com

Technical Support

801-822-5450

support@luxul.com

Copyright and Trademark Notices

No part of this document may be modified or adapted in any way, for any purposes without permission in writing from Luxul. The material in this document is subject to change without notice. Luxul reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication or otherwise under any Luxul intellectual property rights. An implied license only exists for equipment, circuits and subsystems contained in this or any Luxul product.

© Copyright 2018 Luxul. All rights reserved. The name Luxul, the Luxul logo, the Luxul logo mark and Simply Connected are all trademarks and or registered trademarks of Luxul Wireless, Inc. All other trademarks and registered trademarks are property of their respective holders.

LUX-QIG-AMS-1816P-v6 09141802

A brand of legrand®

Luxul AMS-1816P - Technical Support - 1

natural_image Abstract network diagram with interconnected nodes and lines on a dark background (no text or symbols)
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Luxul

Model : AMS-1816P

Category : Switch