METRALINE EXM25 - Multimeter Gossen Metrawatt - Free user manual and instructions
Find the device manual for free METRALINE EXM25 Gossen Metrawatt in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Digital Multimeter |
| Brand | Gossen Metrawatt |
| Model | METRALINE EXM25 |
| Dimensions (H x W x D) | 190 mm x 90 mm x 50 mm |
| Weight | Approx. 400 g (including battery) |
| Power Supply | 9V battery (IEC 6LR61) |
| Display | LCD, 6000 counts |
| True RMS | Yes (AC coupling) |
| DC Voltage Range | 0 to 600 V |
| AC Voltage Range | 0 to 600 V |
| DC Current Range | 0 to 10 A |
| AC Current Range | 0 to 10 A |
| Resistance Range | 0 to 60 MΩ |
| Capacitance Range | 0 to 60 mF |
| Frequency Range | 0 to 60 MHz |
| Diode Test | Yes |
| Continuity Test | Yes (buzzer) |
| Safety Rating | CAT III 600 V |
| Overload Protection | Yes (fuse and PTC) |
| Data Hold | Yes |
| Auto Power Off | Yes |
| Maintenance | Wipe with a dry cloth; do not use solvents |
| Replaceable Parts | Battery and fuses (accessible in battery compartment) |
| Manual Language | English, German |
| Manual Pages | 36 |
Frequently Asked Questions - METRALINE EXM25 Gossen Metrawatt
How do I measure DC voltage with the METRALINE EXM25?
Turn the rotary switch to the V position. Press the DC/AC button to select DC if not shown. Connect the test leads: red to the V jack, black to COM. Touch the probes to the circuit and read the display.
What does the continuity test do and how to use it?
The continuity test emits a beep when the resistance is below approx. 50 Ω. Set the dial to the continuity symbol (diode/continuity). Connect probes across the circuit. The buzzer sounds if the circuit is closed.
How do I replace the battery?
Disconnect test leads. Turn off the meter. Remove the screw on the back cover. Slide off the battery compartment cover. Replace the 9V battery with a new one. Reattach the cover and tighten the screw.
What is the CAT III safety rating?
CAT III refers to measurement category III, suitable for measuring on distribution level circuits (e.g., fixed installations, industrial equipment). The METRALINE EXM25 is rated CAT III 600 V, meaning it can withstand transients up to 600 V.
Can I measure frequency with this multimeter?
Yes. Set the dial to the Hz position. Connect the probes. The meter will display the frequency. For voltage signals, use the voltage ranges; for current, use the mA or A ranges.
What is the maximum current the meter can measure?
The METRALINE EXM25 can measure up to 10 A (AC or DC) for up to 10 seconds per minute. For currents above 600 mA, use the 10A jack; for lower currents, use the mA jack.
How do I clean the multimeter?
Clean the casing with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the meter. Always dry before use.
What does 'Auto Power Off' mean?
The meter automatically turns off after approx. 15 minutes of inactivity to save battery. To wake it, simply press any button or turn the dial.
Where can I find the user manual?
The manual is available for free download at notice-facile.com in PDF format. You can also request a translation in your language via the website.
What type of fuse does the METRALINE EXM25 use?
The meter uses a 10 A ceramic fuse (600 V, high breaking capacity) and a 0.5 A fuse for the mA range. Always replace with the same type and rating.
User questions about METRALINE EXM25 Gossen Metrawatt
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Multimeter in PDF format for free! Find your manual METRALINE EXM25 - Gossen Metrawatt and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. METRALINE EXM25 by Gossen Metrawatt.