Width (approximate) 36 inches (91.4 cm)
Power supply 120 V AC, 60 Hz, 15 or 20 A branch circuit
Suction power 3 speeds + intensive (5 minutes)
Lighting LED lights (replaceable by a technician)
Exhaust type Duct to outside or recirculation (optional kit)
Duct diameter 6 inches (15.2 cm) round
Grease filter Dishwasher-safe metal
Charcoal filter Replaceable every 4-6 months (not included)
Controls Electronic with filter saturation indicator
CFM reduction Function available to limit flow to >300 CFM
Warranty 2 years parts and labor (North America)
Minimum installation (gas) 27 inches (68.6 cm) above cooking surface
Minimum installation (electric/induction) 24 inches (61 cm) above cooking surface
Duct material Metal only
Cleaning Damp cloth with mild detergent, no alcohol
Weight (estimated) About 20 kg (not specified, typical value)

Frequently Asked Questions - ECN636S3 ELICA

What is the recommended installation height for the ECN636S3 hood above a gas stove?
For a gas stove, the lower edge of the hood must be installed at least 27 inches (68.6 cm) above the cooking surface. For electric or induction stoves, the minimum height is 24 inches (61 cm). It is recommended not to exceed 36 inches (91.4 cm) for optimal efficiency.
How to clean the grease filter of the ECN636S3 hood?
The metal grease filter should be cleaned once a month. You can wash it by hand with a mild detergent or in the dishwasher on low temperature and short cycle. To remove it, pull the spring handle downward.
How to replace the charcoal filter of the hood?
The charcoal filter is used only in recirculation mode. It attaches by bayonet to the motor. Turn the filter clockwise to lock it. It must be replaced every 4 to 6 months depending on use. The charcoal filter is not supplied with the hood (ref. KIT02667).
How to reset the filter saturation indicator?
After cleaning or replacing the filters, you must reset the indicator. With the hood off, press and hold the OFF (1) button for about 3 seconds until the indicator turns off. The indicator can only be reset within one minute after the hood is turned off.
How to reduce the maximum airflow (CFM) of the hood?
If your region limits airflow, you can activate the CFM reduction mode. With the motor off, simultaneously press the ON/OFF (1) and Intensive (5) buttons for 3 seconds. A beep sounds and speeds 3 and 4 are disabled, limiting the flow to more than 300 CFM.
What are the electrical requirements for installing the ECN636S3 hood?
The hood requires a 120 V AC, 60 Hz power supply on a 15 or 20 A branch circuit. Connection must be made by a qualified electrician, with copper wires and grounding complying with local codes. Use metal conduit and a UL- or CSA-listed cable connector.
Can the hood be used without external venting?
Yes, it is possible to use the hood in recirculation mode. You must purchase the recirculation kit (ref. KIT02665) which includes a deflector and charcoal filters. In this configuration, the air is filtered then returned to the kitchen.
What is the warranty period and what does it cover?
The warranty is 2 years from the date of purchase. It covers defective parts, labor, and in-home service. It does not cover accidental damage, misuse, filters, light bulbs, or normal wear. The warranty applies to the original purchaser in North America.
What to do if the hood stops working?
First check that the power supply is correct (circuit breaker, fuse). If the problem persists, turn off the power and inspect the wiring. Do not attempt to repair internal components yourself. Contact Elica North America customer service at (888) 732-8018 or 1-888-651-2534 (Eastern Canada).
What type of duct to use for exhaust?
Use only rigid metal ducts of 6 inches (15.2 cm) diameter. Flexible ducts are prohibited. Ensure the duct leads outside, with as few elbows as possible. Install a backdraft damper if necessary to prevent cold air backflow.

User questions about ECN636S3 ELICA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Range hood in PDF format for free! Find your manual ECN636S3 - ELICA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ECN636S3 by ELICA.

USER MANUAL ECN636S3 ELICA

Models:

CN636S3

ECN642S3

Use, Care, and Installation Guide

Guide

d'utilisation,

d'entretien et

d'installation

Guía de

instalación, uso y

mantenimiento

READ AND SAVE THESE

INSTRUCTIONS

LISEZ CES

INSTRUCTIONS ET

CONSERVEZ-LES

LEA Y CONSERVE

ESTAS INSTRUCCIONES

LIB0131120

Printed in Mexico

04/17

ENGLISH

Contents

Important safety notice....3

Electrical & installation requirements 4

Before installing the hood 4

Dimensions and clearances.... 4

List of materials....5

Parts supplied 5

Parts not supplied 5

Ducting options and examples.... 6

Installation 6

Electrical connection....10

Complete the installation.... 10

Description of the hood....12

Control....12

Maintenance 13

Warranty 14

APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.

IMPORTANT: Save these Instructions for the Local Electrical Inspector's use.

INSTALLER: Please leave these Instructions with this unit for the owner.

OWNER: Please retain these instructions for future reference.

Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring this appliance. Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit.

IMPORTANT SAFETY NOTICE

| CAUTION

FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPOURS.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
B. Before servicing or cleaning the unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

C. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes & standards, including fire-rated construction.
D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (Chimney) of fuel burning equipment to prevent back- drafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the national fire protection association (nfpa), the american society for heating, refrigeration and air conditioning engineers (ASHRAE), and the local code authorities.

E. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
F. Ducted systems must always be vented to the outdoors.

| CAUTION

To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.

Install this hood in accordance with all requirements specified.

WARNING

To reduce the risk of fire or electric shock, do not use this hood with any external solid state speed control device.

WARNING

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.

a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe').
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.

I WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: 4

a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or other metal tray, then turn off the gas burner or the electric element. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - you may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
d) Use an extinguisher ONLY if:

1) You know you have a class ABC extinguisher, and you already know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit.

a Based on "Kitchen Fire Safety Tips" published by NFPA.

OPERATION

Always leave safety grills and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.

The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.

The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.

I CAUTION

Automatically Operated Device - To Reduce The Risk Of Injury Disconnect From Power Supply Before Servicing.

ELECTRICAL & INSTALLATION REQUIREMENTS

IMPORTANT

Observe all governing codes and ordinances.

It is the customer's responsibility:

• To contact a qualified electrical installer.
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91-latest edition** and all local codes and ordinances.
- If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
- Do not ground to a gas pipe.
- Check with a qualified electrician if you are not sure range hood is properly grounded.
- Do not have a fuse in the neutral or ground circuit.

IMPORTANT

  • Save Installation Instructions for electrical inspector's use.
    • The range hood must be connected with copper wire only.
  • The range hood should be connected directly to the fused disconnect (Or circuit breaker) box through metal electrical conduit.
  • Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2 No. O-M91 - latest edition** and all local codes and ordinances.
  • A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood and at the junction box).

Copies of the standards listed may be obtained from:

* National Fire Protection Association Batterymarch Park Quincy,

Massachusetts 02269

** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575

BEFORE INSTALLING THE HOOD

1 For the most efficient air flow exhaust, use a straight run or as few elbows as possible.

CAUTION: Vent unit to outside of building, only.

2 At least two people are necessary for installation.
3 Fittings material is provided to secure the hood to most types of walls/ceilings, consult a Qualified Installer, check if they perfectly fit with your cabinet/wall.
4 Do not use flex ducting.
5 COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the ducting enters the heated portion of the house.

6 Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation

Systems greater than specified CFM of air movement.

The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.

DIMENSIONS AND CLEARANCES

F E G A B C D

Models
ECN636S3ECN642S3
A 36" (91.44 cm) 42" (106 cm)
B25 1/4 " (64 cm)
C*Max: 49 1332 " (125.3 cm)Min: 29 1332 " (74.5 cm)
D**Max: 44 2164 " (112.4 cm)Min: 29 1532 " (74.5 cm)
E6" (15.24 cm)
F12" (30.5 cm)
G13 564 " (33.2 cm)
  • Ductless (Recirculating) version
    ** Ducted version

LIST OF MATERIALS

Removing the packaging.

I CAUTION

Remove carton carefully, Wear gloves to protect against sharp edges.

I WARNING

Remove the protective film covering the product before putting into operation.

Supplied Part Pieces Supplied Part Pieces

ELICA ECN636S3 - I WARNING - 1
Hood assembly with blower and LED lamps already installed
5x45 mm4
[W08Y]4.2x8 mm62
ELICA ECN636S3 - I WARNING - 23.5x9.5 mm2
[443S]3.5x6.5 mm4
ELICA ECN636S3 - I WARNING - 32.9x3 mm2
ELICA ECN636S3 - I WARNING - 4Leveling screws2
ELICA ECN636S3 - I WARNING - 58x40 mm4

Two isometric line drawings of rectangular metal profiles with internal cutouts (no text or symbols)

ELICA ECN636S3 - I WARNING - 7
6" round air transition

ELICA ECN636S3 - I WARNING - 8Duct cover brackets4
ELICA ECN636S3 - I WARNING - 9vertical supportsUpper: 4Lower: 4
ELICA ECN636S3 - I WARNING - 10Torx adapter#10: 1#20: 1
ELICA ECN636S3 - I WARNING - 11Mounting template1

Parts no supplied

Tools/Materials required

  • Wire
  • Tape to mount template
  • 6" (15.2 cm) rounded metal duct length to suit installation
  • Measuring tape
  • Pliers
  • Gloves
  • Knife
  • Safety glasses
    • Electric drill with 5/6 " and 3/8 " bits
  • Strain relief
  • Spirit level
  • Duct tape
  • Screwdrivers:

- Phillips (Posidrive) #2

- TORX #10, #20

  • Wire cutter/stripper
  • Masking tape
  • Hammer
  • Saw, jig saw or reciprocating saw

Optional accessories and consumable parts

KIT # Part
36" (91.4 cm) 42" (106.7 cm)
Recirculating KitKIT02665
Duct Cover Extension KitKIT0100317
Charcoal Filter ReplacementKIT02667

Ducting options

Closely follow the instructions set out in this manual.

All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined.

Ducting version Ductless (Recirculating

The hood is equipped with a 6" (15.2 cm) round transition for discharge of fumes to the outside.

B A

A. 6" round Transition
B. 6" round duct

In cases where it should not be possible to discharge cooking fumes and vapour to the outside.

Attach a charcoal filter and the deflector on the duct cover support bracket.

Fumes and vapours are recycled through the top grille by means of a duct connected to the transition and the transition mounted on the deflector.

See accessories section.

C A B

A. 6" round Transition
B. 6" round duct
C. Air deflector

Preparation

Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.

Fittings material is provided to secure the hood to most types of walls/ceilings.

However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

I CAUTION

For gas cooktop & range installations: Mount the hood so the bottom is at least 30" (76.2 cm) above the cooking surface. For electric/induction cooktop & range installations: Mount the hood so the bottom is at least 24" (61 cm) above the cooking surface.

There is no maximum mounting height, however, we recommend mounting the hood no greater than 36" (91.4 cm) above the cooking surface. For every inch (2.54 cm) above 36" (91.4 cm), fume and moisture capture efficiency diminishes at an increasing rate and may not deliver an acceptable level of ventilating performance.

This hood is intended for household use.

PLEASE READ THE INSTALLATION MANUAL FOR SPECIFIC APPLICATION. Check your ceiling height and hood height before selecting your hood.

Installation

Ceiling support structures

  • This vent hood is heavy. Adequate structure and support must be provided in all types of installations.
  • At the hood location, install 2"x 4" cross framing between ceiling joists as shown. (2"x 4" are required to support the weight of the hood.)
  • Arrange cross framing in the ceiling to suit the existing structure.
  • Your ceiling joists will be like one of the following:

Example A
NOTE: Top view ceiling joists parallel to front of hood 10½" (25.5 cm) install cross- framing symmetrically over duct/cooktop Centerline Ø 6¼" (15.9 cm) duct 7½" (17.9cm) 16" (40.6 cm) joist spacing 2 x 4 cross framing Hood front Align duct to center of cooktop Cooktop outline

Example B
NOTE: Top view ceiling joists parallel to front of hood 16" (40.6 cm) joist spacing 7½" (17.9cm) 10½" (25.5 cm) install cross-framing symmetrically over duct/cooktop Centerline Ø 6¼" (15.9 cm) duct 2 x 4 cross framing Hood front Align duct to center of cooktop Cooktop outline

Example C
NOTE: Top view ceiling joists parallel to front of hood Centerline 10½" (25.5 cm) install cross-framing symmetrically over duct/cooktop 2 x 4 cross framing Ø 6½" (15.9 cm) duct 7½" (17.9cm) 16" (40.6 cm) joist spacing Hood front Align duct to center of cooktop Cooktop outline

Install Range Hood

1 Place the template in the ceiling considering the instructions for ceiling support structures.

NOTE: Always consider the front of hood legend when playing the template on the ceiling. It will define the control's location.

Line drawing of a person using a handheld device to interact with a board (no text or symbols)

2 Mark with a pencil the hole locations for screws and duct in the ceiling.

Illustration of a person using a tool to examine a small object on a table, with no visible text or symbols.

3 Fix the upper horizontal support with 4 - 5x45 mm screws.

Line drawing of a person adjusting a rectangular object on a surface (no text or symbols)

4 Install the 6" (15.2 cm) round transition with 2 - 3.5x9.5 mm screws.

A. 6" round Transition B. Hood assembly C. 2 - 3.5x9.5 mm screws

5 Install the lower horizontal support with 8 - 4.2x8 mm screws.

A. Lower horizontal support B. 8 - 4.2x8 mm screws

6 Install the 4 vertical supports with 16 - 4.2x8 mm screws.

A. 4- Upper vertical supports B. 16 - 4.2x8 mm screws

7 Install the structure to the horizontal support with 16 - 4.2x8 mm screws.

C. Upper horizontal support D. 16 - 4.2x8 mm screws

8 Using 2 or more people, lift the range hood assembly under the structure.

A. Lower vertical supports B. Range hood assembly

9 Attach the range hood assembly to the lower vertical supports with 2 leveling screws.

10 Install the 4 vertical supports with 16 - 4.2x8 mm screws. Check everything is tightly screwed.

A. 2 - Leveling screws B. Lower vertical support C. Place leveling screws through the structure

A. 4 - Lower vertical supports B. 16 - 4.2x8 mm screws

11 Remove the 2 leveling screws from the structure.

Technical diagram showing labeled components A and B with alignment lines and structural details

A. 2 - Leveling screws

Electrical Connection

I WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.

ELECTRICAL SHOCK HAZARD.

I WARNING

TURN OFF POWER CIRCUIT AT THE SERVICE PANEL BEFORE WIRING THIS UNIT.

120 VAC, 15 OR 20 AMP CIRCUIT REQUIRED.

- Facing the front of the range hood, remove the left knockout and the Junction box cover and install the conduit connector (cULus listed) in junction box.

A. B. A. Knockout B. Junction box cover

ELECTRICAL GROUNDING INSTRUCTIONS

This appliance is fitted with an electrical junction box with 3 wires, one of which (green/yellow) serves to ground the appliance.

To protect you against electric shock, the green and yellow wire must be connected to the grounding wire in your home electrical system, and it must under no circumstances be cut or removed.

Failure to do so can result in death or electrical shock.

- If not already done, install a 1/2 " conduit connector in junction box.

Technical line drawing of a mechanical assembly with no visible text or symbols

A. 1/2 " Conduit connector

  • Run home power supply cable through the conduit, into terminal box.
  • Use UL listed wire connectors and connect black wires (B) together.
  • Use UL listed wire connectors and connect white wires (D) together

A B C D E

A. Home power supply cable
B. Black wires
C. UL listed wire connectors

D. White wires

E. Green (or bare) and yellow-green ground wires

  • Connect green (or bare) ground wire from home power supply to yellow-green ground wire (E) in terminal box using UL listed wire connectors.
  • Tighten strain relief screw.
    • Install terminal box cover.
  • Check that all light bulbs are secure in their sockets.
  • Reconnect power

Complete the Installation

ONLY FOR RECIRCULATING VERSION (Using Recirculating Kit model KIT02665)

Air deflector installation

- Assemble the air deflector with the upper horizontal support with 2 assembly screws.

Technical line drawing of a mechanical component with labeled points A and B (no text or symbols beyond labels)

A. Air deflector
B. Assembly screws

• Measure from the bottom of the air deflector to the bottom of the hood outlet, as shown.

Technical line drawing of a mechanical assembly with a cylindrical component and two stacked components, labeled A (no text or symbols present)

A. Dimension to measure

• Cut the duct at the measured size.
- Slip the duct onto the bottom of the deflector.
- Place the duct over the exhaust outlet from the hood.
- Use duct tape to seal the deflector and at the exhaust outlet from the hood.
- The charcoal filters needs to be clipped on the motor as the image below shown.

Diagram illustrating the installation of a fan blade assembly with labeled components and directional arrows indicating motion.

Duct cover installation (both ducted and non ducted versions)

- Attach the upper duct covers using 6 - 3.5x6.5 mm screws. NOTE: For non-ducted (recirculating) installation, the slotted holes in the upper duct covers will be visible when assembled. For ducted installations, the slotted holes will be hidden down inside the lower duct covers.

Technical diagram of a mechanical device with labeled components A, B, and C

A. Upper duct covers
B. 4 - 3.5x6.5 mm installation screws
C. 2 - 2.9x3 mm screws

- Place lower duct covers using one plastic bracket at each side (4 needed).

A B

A. Lower duct covers
B. 4 - Duct cover plastic bracket

- Secure the lower duct cover to the range hood canopy using 4 - 4.2 x 8 mm screws.

Isometric technical diagram of a layered mechanical or architectural structure with no visible text or symbols

A. 4 - 4.2x8 mm screws

Description of the hood

Technical diagram of a kitchen or oven structure with numbered components labeled 1 through 6.

  1. Blower and light controls
  2. LED lights
  3. Grease filter handle
  4. Grease filter
  5. Canopy
  6. Duct covers

Control

ELICA ECN636S3 - Control - 1
123456

ELICA ECN636S3 - Control - 2

ELICA ECN636S3 - Control - 3

ELICA ECN636S3 - Control - 4

ELICA ECN636S3 - Control - 5

ELICA ECN636S3 - Control - 6

  1. Button ON/OFF motor (stand by)
  2. Button for low speed (suction power) selection When flashing, it indicates that you must wash the grease filter.
  3. Button for medium speed (suction power) selection
  4. Button for high speed (suction power) selection
  5. Button for intensive speed (suction power) selection It lasts 5 minutes then it returns to medium speed (suction power).
  6. Button ON/OFF lighting Press briefly to switch on or off the lighting of the hood. Press and hold to adjust the intensity of the light.

Indicators of filter saturation:

At regular time intervals, the hood indicates the need of performing filter maintenance.

ELICA ECN636S3 - Indicators of filter saturation: - 1

Button MAX on with steady light:

Perform grease filter maintenance.

ELICA ECN636S3 - Button MAX on with steady light: - 1

Button flashing:

Perform activated charcoal filter maintenance.

Note: Filter saturation signal is visible within the first minute after switching off the hood; within this time, the reset of saturation indicators must be performed.

Reset of filter saturation indicators:

Press and hold the button

ELICA ECN636S3 - Reset of filter saturation indicators: - 1

Activation of saturation indicator activated charcoal filter: Note: This operation must be performed with the hood off. This indicator is normally deactivated; press and hold the

button to activate the function: the button lights up with steady light.

To deactivate the function, press and hold the button, the button lights up flashing.

ELICA ECN636S3 - Reset of filter saturation indicators: - 2

CFM Reduction System

Before operating your hood:

Some States and Provinces of the US & Canada restrict the maximum exhausting airflow of range hoods.

Airflow is measured as cubic feet per minute (CFM). These maximum levels allowed are detailed in the local code of your area. Please check local codes to find out if you need to restrict the maximum airflow of your hood. If your local code mandates a maximum airflow level below the maximum airflow of this hood (i.e. 600 CFM), please execute the procedure below to reduce the maximum airflow.

1 1 ① ② ③ 5 MAX

1 Turn the motor OFF.
2 Press the ON/OFF (1) and Intensive speed (5) buttons together for 3 seconds. You will hear a beep and all control lights will illuminate for 3 seconds. This action will Disable speeds 3 and 4 and effectively lower the Maximum airflow to >600 CFM.
3 Locate the CFM certification sticker in the hardware pack.
4 Peel and Affix this sticker to a visible area in the blower. This sticker provides official certification to your local inspector that this hoods maximum airflow has been reduced to >600 CFM.

Maintenance

| ATTENTION!

Before performing any maintenance operation, isolate the hood from the electrical supply by switching off at the connector and removing the connector fuse.

Or if the appliance has been connected through a plug and socket, then the plug must be removed from the socket.

Cleaning

Do not spray cleaners directly to the control while cleaning the Hood. The cooker hood should be cleaned regularly (at least with the same frequency with which you carry out maintenance of the fat filters) internally and externally. Clean using the cloth dampened with neutral liquid detergent. Do not use abrasive products.

DO NOT USE ALCOHOL!

I WARNING

Failure to carry out the basic cleaning recommendations of the cooker hood and replacement of the filters may cause fire risks. Therefore, we recommend oserving these instructions.

The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.

Grease filter

Traps cooking grease particles.

This must be cleaned once a month using non aggressive detergents, either by hand or in the dishwasher, which must be set to a low temperature and a short cycle. When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity.

To remove the grease filter, pull the spring release handle.

Diagram of a grid-patterned electronic device with a central square component and labeled point A (no text or symbols beyond labels)

A. Spring release handle

Replacing a LED Lamp

The LED lights are replaceable by a service technician only. See "Who to contact" section in the warranty for service contact information.

Charcoal filter

If the model is not vented to the outside, the air will be recirculated through disposable charcoal filters that help remove smoke and odors.

1 Cover the grill that protects the suction motor with the carbon filter so that the slots on the filter correspond to the pins on the sides of the motor protection grill.
2 Turn the carbon filter clockwise to block them (bayonet fixing).

NOTE: The charcoal filters cannot be cleaned. It should be replaced every 4-6 months (depending on hood usage).

Diagram of a mechanical fan assembly with internal blades and a rotating knob (no text or labels)

TO OBTAIN SERVICE UNDER WARRANTY

Owner must present proof of original purchase date. Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.

PARTS AND SERVICE WARRANTY

For the period of two (2) years from the date of the original purchase, Elica will provide free of charge, non consumable parts or components that failed due to manufacturing defects. During these two (2) years limited warranty, Elica will also provide free of charge, all labor and in-home service to replace any defective parts.

WHAT IS NOT COVERED

• Damage or failure to the product caused by accident or act of God, such as, flood, fire or earthquake.
- Damage or failure caused by modification of the product or use of non-genuine parts.
- Damage or failure to the product caused during delivery, handling or installation.
- Damage or failure to the product caused by operator abuse.
• Damage or failure to the product caused by dwelling fuse replacement or resetting of circuit breakers.
- Damage or failure caused by use of product in a commercial application.
• Service trips to dwelling to provide use or installation guidance.
• Light bulbs, metal or carbon filters and any other consumable part.
• Normal wear of finish.
- Wear to finish due to operator abuse, improper maintenance, use of corrosive or abrasive cleaning products/pads and oven cleaner products.

WHO IS COVERED

This warranty is extended to the original purchaser for products purchased for ordinary residential use in North America (Including the United States, Guam, Puerto Rico, US Virgin Islands & Canada).

This warranty is non-transferable and applies only to the original purchaser and does not extend to subsequent owners of the product. This warranty is made expressly in lieu of all other warranties, expressed or implied, including, but not limited to any implied warranty of merchantability or fitness for a particular purpose and all other obligations on the part of Elica North America, provided, however, that if the disclaimer of implied warranties is ineffective under applicable law, the duration of any implied warranty arising by operation of law shall be limited to two (2) years from the date of original purchase at retail or such longer period as may be required by applicable law.

This warranty does not cover any special, incidental and/or consequential damages, nor loss of profits, suffered by the original purchaser, its customers and/or the users of the Products.

WHO TO CONTACT

To obtain service under warranty or for any service related question:

• Elica North America Service, call at 1 888 732 8018
• For Eastern Canada, call AGI Services at 1 888 651 2534 Ask for the service department
• elica@servicepower.com

FRANÇAIS

Table des matières

Electrical connection.... 23

Achever l'installation 23

Description de la hotte 25

Commandes 25

Entretien 26

Garantie 27

APPROUVÉ POUR LES APPAREILS DE TYPE RÉSIDENTIEL POUR UNE UTILISATION RÉSIDENTIELLE SEULEMENT LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES

VEUILLEZ LIRE CES INSTRUCTIONS AU COMPLET AVANT DE COMMENCER.

L'INSTALLATION DE L'APPAREIL DOIT RESPECTER TOUS LES CODES EN VIGUEUR.

Modèles
ECN636S3ECN642S3
A36" (91,44 cm)42" (106 cm)
B 251/4" (64 cm)
C*Max: 4913/52" (125,3 cm)Min: 2913/52" (74,5 cm)
D**Max: 4421/54" (112,4 cm)Min: 2913/52" (74,5 cm)
E6" (15,24 cm)
F12" (30,5 cm)
G 135/64" (33,2 cm)

A. Serre-câble d'

A. 4 vis - 4,2 x 8 mm

Description de la hotte
Technical diagram of a kitchen or oven structure with numbered components labeled 1 through 6.

These maximum levels allowed are detailed in the local code of your area. Please check local codes to find out if you need to restrict the maximum airflow of your hood. If your local code mandates a maximum airflow level below the maximum airflow of this hood (600 CFM), please execute the procedure below to reduce the maximum airflow.

1 1 ① ② ③ 5 MAX

3 Locate the CFM certification sticker in the hardware pack.
4 Peel and Affix this sticker to a visible area in the blower. This sticker provides official certification to your local inspector that this hoods maximum airflow has been reduced to >300 CFM.

Entretien

| ATTENTION!

POUR OBTENIR UN DEPANNAGE SOUS GARANTIE

DIMENSIONES DEL PRODUCTO

A B C D E F G

Modelos

ECN636S3 ECN642S3
A 36" (91.44 cm) 42" (106 cm)
B 25 1/4" (64 cm)
C* Máx: 49 13/32" (125.3 cm)Mín: 2913/32" (74.5 cm)
D** Máx: 44 21/34" (112.4 cm)Mín: 2913/32" (74.5 cm)
E6" (15.24 cm)
F12" (30.5 cm)
G 135/64" (33.2 cm)

- Phillips (Posidrive) #2

- TORX #10, #20

A. Soporte superior superior B. 16 tornillos - 4.2 x 8 mm

A. 4 - Tornillos 4.2 x 8 mm

A. Manija de desenganche

PARA OBTENER SERVICIO DENTRO DE GARANTÍA