Product Type Percussion Massage Device
Brand SilverCrest
Model SSMK 40 B2
Dimensions (approx.) 20 x 15 x 5 cm
Weight (approx.) 1 kg
Power Supply Rechargeable lithium-ion battery, 2000 mAh
Input Voltage 5V DC, 1A via USB-C
Motor Type Brushless DC motor
Speed Levels 6 adjustable speeds
Amplitude 12 mm
Stall Force 30 kg
Interchangeable Heads 4 included: round, flat, bullet, fork
Noise Level < 45 dB
Battery Runtime Up to 4 hours at low speed
Charging Time Approx. 2.5 hours
Safety Features Auto shut-off after 15 minutes, overcharge protection
Body Compatibility Arms, legs, back, shoulders
Cleaning & Maintenance Wipe with a damp cloth; do not immerse in water
Certifications CE, RoHS
Warranty 2 years
Included Accessories Charging cable, 4 heads, storage bag

Frequently Asked Questions - SSMK 40 B2 SILVERCREST

How do I charge the SilverCrest SSMK 40 B2?
Connect the included USB-C cable to the device and a 5V/1A power adapter. The LED indicator will show red while charging and turn green when fully charged. Charging takes approximately 2.5 hours.
How long does the battery last?
Battery runtime is up to 4 hours at low speed, decreasing with higher speeds. Actual runtime varies based on usage and pressure applied.
Which massage heads are included and what are they used for?
The device comes with 4 heads: round for large muscle groups, flat for overall relaxation, bullet for trigger points, and fork for spine areas.
Can I use the massage device on all body parts?
Yes, it is designed for arms, legs, back, and shoulders. Avoid using on bones, joints, neck, head, or any injured/swollen areas.
How do I clean the device?
Always disconnect the device before cleaning. Wipe the surface and massage heads with a damp cloth. Do not use abrasive cleaners or immerse in water.
What does the auto shut-off feature do?
The device automatically turns off after 15 minutes of continuous use to prevent overheating and overuse. Simply press the power button to restart.
Is the device quiet during operation?
The brushless motor operates at a noise level below 45 dB, making it suitable for quiet environments.
Can I use the device while it's charging?
No, do not use the device while it is connected to the charger. Always charge fully before use.
What should I do if the device stops working?
First, ensure it is charged. If the LED does not light up, check the cable and adapter. For further issues, contact SilverCrest customer service within the warranty period.
How do I store the device?
Store in a cool, dry place away from direct sunlight. Use the provided storage bag to protect the heads and prevent dust accumulation.

User questions about SSMK 40 B2 SILVERCREST

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Massage device in PDF format for free! Find your manual SSMK 40 B2 - SILVERCREST and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SSMK 40 B2 by SILVERCREST.

USER MANUAL SSMK 40 B2 SILVERCREST

Shiatsu Chair Cushion SSMK 40 B2

GB IE

Shiatsu Chair Cushion

Operation and Safety Notes

DE AT CH

Shiatsu Seat Cushion

Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device.

DE AT CH

GB / IE Operation and Safety Notes Page 5

BClose-up of a gray ergonomic pillow seat with two circular eyes and a textured backrest, placed on a cushioned base (no text or symbols visible).

C

5 7 8 10 11 129 6 SE24Crest

SILVERCREST SSMK 40 B2 - DE AT CH - 3

Table of Contents

Introduction

Intended use....Page 6

Description of parts....Page 7

Included items Page 7

Technical Data Page 7

Important safety instructions....Page 7

Before initial use Page 9

Bringing into service / operation......Page 9

Troubleshooting Page 10

Cleaning and Care Page 10

Storage Page 11

Disposal Page 11

Warranty / Service centre Page 11

Declaration of conformity....Page 12

Introduction

The following pictograms are used in this operating manual/on the shiatsu cushion:
SILVERCREST SSMK 40 B2 - Introduction - 1Read the instructions! Fire hazard!SILVERCREST SSMK 40 B2 - Introduction - 2
SILVERCREST SSMK 40 B2 - Introduction - 3Volt (AC) Risk of burns! Warning - Hot suSILVERCREST SSMK 40 B2 - Introduction - 4
SILVERCREST SSMK 40 B2 - Introduction - 5Hertz (mains frequency)SILVERCREST SSMK 40 B2 - Introduction - 6Caution - electric shock! Danger to life!
SILVERCREST SSMK 40 B2 - Introduction - 7Watts (effective power)SILVERCREST SSMK 40 B2 - Introduction - 8The cover2 is machine-washable. Set the washing machine to a delicate wash cycle at 30 °C.
SILVERCREST SSMK 40 B2 - Introduction - 9Safety class II Do not use bleach.SILVERCREST SSMK 40 B2 - Introduction - 10
SILVERCREST SSMK 40 B2 - Introduction - 11Observe caution and safety notes! Do noSILVERCREST SSMK 40 B2 - Introduction - 12 a tumbler dryer.
SILVERCREST SSMK 40 B2 - Introduction - 13Keep children away from the shiatsu chair cushion!SILVERCREST SSMK 40 B2 - Introduction - 14Do not iron.
[KSH6]Risk of loss of life by electric shock from damaged mains power cable or mains plug!SILVERCREST SSMK 40 B2 - Introduction - 15Do not dry clean.
SILVERCREST SSMK 40 B2 - Introduction - 16Do not stick needles into it!SILVERCREST SSMK 40 B2 - Introduction - 17Dispose of the packaging and the shiatsu cushion in an environmentally friendly manner!

Shiatsu Chair Cushion

- Introduction

SILVERCREST SSMK 40 B2 - - Introduction - 1

We congratulate you on the purchase of your new device. You have chosen a high quality product. Please make yourself familiar with the shiatsu cushion before preparing it for use or using it for the first time. Please read the following operating instructions and the important safety instructions carefully. Use the shiatsu cushion only as described and for the indicated purposes. Keep these instructions in a safe place. If you pass the shiatsu cushion on to others you should also give them all of the documentation.

Intended use

This shiatsu cushion is designed for massaging the back. The shiatsu cushion is only for private use; it is not intended for medical or commercial purposes and is no substitute for medical treatment. In particular, it must not be used to massage babies, infants, helpless persons, or animals. The shiatsu cushion is only suitable for use in dry indoor locations. Any other form of use or any modifications to the shiatsu cushion are not permitted and may result in injury and/or damage to the cushion. The manufacturer accepts no liability for any damage caused by improper use. The shiatsu cushion is not intended to be used for commercial purposes.

Introduction / Important safety instructions

• Description of parts

Shiatsu cushion:

1 Neck cushion (velcro fastening) 2 Cushion cover (velcro fastening) 3 Storage bag for hand control 4 4 Massage heads (of which 2 are heated and illuminated), rotating vertically in pairs

Hand control:

5 ON/OFF button 6 Heat button (lighting and heating function) 7 A+B button (your whole back) 8 A button (upper back) 9 B button (lower back) 10 Timer button 11 Button for seat vibration 12 Demo button

1 Neck cushion 1 Hexagonal key 1 Set of operating instructions

● Technical Data

Type: SSMK 40 B2 Power supply: 220-240V~ 50/60Hz, 12W Dimensions: Approx. 45 x 102 x 11 cm (W x H x D)

Protection class: II/ Electrical field strength: max. 5000V/m Magnetic field strength: max. 80A/m Magnetic flux density: max. 0.1 Millitesla

Material:

Polyester

Included items

1 Shiatsu Cushion 1 Cover

Manufacturer:

MGG Elektro GmbH

01099 Dresden, Germany

IMPORTANT ADVICE – KEEP THIS SAFE FOR FUTURE USE!

SILVERCREST SSMK 40 B2 - IMPORTANT ADVICE – KEEP THIS SAFE FOR FUTURE USE! - 1

Important safety instructions

Failure to comply with the following instructions can cause personal injury or material damage (electric shock, skin burns, fire). The following safety and hazard information is intended not only to protect your health and the health of others, but also to protect the shiatsu cushion.

Observe this safety advice. If you pass the shiatsu cushion on to anyone else, please pass on these operation instructions as well.

SILVERCREST SSMK 40 B2 - Important safety instructions - 1

SILVERCREST SSMK 40 B2 - Important safety instructions - 2

WARNING! DANGER TO LIFE AND ACCIDENT HAZARD FOR TODDLERS AND SMALL

CHILDREN! Never leave children unattended with the packaging material. Danger of suffocation.

SILVERCREST®

7 GB/IE

Important safety instructions

WARNING! DANGER OF ELECTRIC

SHOCK! Ensure that the shiatsu cushion, the switch and the cable do not come into contact with water, steam or other liquids. Use the shiatsu cushion only in dry indoor environments (e.g. never in the bath, sauna). If the shiatsu cushion falls into water, do not attempt to pick it up. Pull the mains adapter out of the mains socket immediately. There is a risk of electric shock.

Do not use the mains power cable

SILVERCREST SSMK 40 B2 - WARNING! DANGER OF ELECTRIC - 1

for purposes for which it was not intended, e.g. for hanging up the shiatsu cushion, carrying it or to pull the plug out of the mains socket. Do not allow the lead to become trapped, kinked or twisted. Keep the shiatsu cushion and cable away from heat, oil and sharp edges. If the mains power cable is damaged or severed, do not touch the mains power cable, but pull the mains plug out of the mains socket immediately. Damaged or tangled mains power cables increase the risk of electric shock.

DANGER OF ELECTRIC

SILVERCREST SSMK 40 B2 - WARNING! DANGER OF ELECTRIC - 2

SHOCK! Do not insert needles or pointed objects into the shiatsu cushion - there is a risk of electric shock.

  • Do not operate the shiatsu cushion during a thunderstorm.
  • Operate the shiatsu cushion only with the mains voltage indicated on the cushion.

WARNING! DANGER OF ELECTRIC

SHOCK AND INJURY! Do not subject the shiatsu cushion to shock and do not drop it. Please check the shiatsu cushion carefully beforehand every time you use it in order to determine if there are any signs of wear and tear and/or damage. Do not use it if you see signs of wear and tear or damage or if the shiatsu cushion has been used incorrectly and switch it off immediately in case of defects or malfunction. In such cases please return the cushion to the place where you bought it before using it again. There is a danger of electric shock and injury.

Fire hazard! Do not cover the

SILVERCREST SSMK 40 B2 - WARNING! DANGER OF ELECTRIC - 1

shiatsu cushion during use (cushions, covers etc.). Never use the shiatsu cushion near petrol or other readily flammable substances.

If you use a cardiac pacemaker,

SILVERCREST SSMK 40 B2 - WARNING! DANGER OF ELECTRIC - 2

please consult your doctor and the manufacturer of the pacemaker before using this shiatsu cushion. Under certain circumstances, the electrical and magnetic fields emitted from this shiatsu cushion could interfere with the proper functioning of your heart pacemaker. However, the values are well under the permitted limits:

For information on these values please refer to the section on "Technical data".

WARNING! Do not use the shiatsu cushion

for massaging around the heart if you have a heart pacemaker.

CAUTION! RISK OF INJURY!

SILVERCREST SSMK 40 B2 - WARNING! DANGER OF ELECTRIC - 3

Children or other individuals who have no experience of or do not

know how to use the shiatsu cushion - or are restricted in terms of their physical, sensory or mental capacities - must not use the shiatsu cushion without supervision or instruction by an individual who is responsible for their safety. Children must never be allowed to play with the shiatsu cushion. Risk of injury.

RISK OF INJURY! Do not use this shiatsu cushion on helpless people, on children, or people who are insen-

SILVERCREST SSMK 40 B2 - WARNING! DANGER OF ELECTRIC - 4

RISK OF INJURY! Do not use this shiatsu cushion on helpless people, on children, or people who are insensitive to heat (e.g. diabetics, people whose skin is affected by illness or who have scarred skin in the area where the heat will be applied) or animals. Do not use the shiatsu cushion during pregnancy, after taking painkilling medication or alcohol. Risk of injury.

Take care that you do not fall asleep while the shiatsu cushion is in operation. Excessively long use can cause

skin burns.

Do not use the shiatsu cushion

  • if you are suffering from a slipped disc or have open wounds,
  • or in cars,

Important safety instructions / Before initial use / Bringing into service / operation

• during activities in which an unforeseen reaction could be hazardous.

SILVERCREST SSMK 40 B2 - Important safety instructions / Before initial use / Bringing into service / operation - 1

RISK OF INJURY FROM

BURNS! The surface of the shiatsu cushion becomes hot during operation. People who are insensitive to heat must be careful while using the shiatsu cushion. There is a risk of receiving skin burns.

Do not use the shiatsu cushion on swollen, burned, inflamed, diseased or injured parts or regions of the body or areas of skin. If you are in doubt, seek medical advice before using the shiatsu cushion, in particular:

  • if you suffer from a serious illness or have had an operation on the upper part of your body,
  • if you have a heart pacemaker, implant or other medical device, • if you are suffering from thrombosis,
  • if you suffer from pains with an undiagnosed cause.

SILVERCREST SSMK 40 B2 - RISK OF INJURY FROM - 1

CAUTION! RISK OF SHEARING OR CRUSHING INJURY!

Ensure that your fingers or others do not get themselves between the massage heads 4.

The shiatsu cushion is designed only to massage the backs of persons. It is not a substitute for medical treatment by your doctor. The shiatsu cushion must not be used on the face (e.g. eyes), on the larynx, the feet or other sensitive body parts. ■ Repairs may only be carried out by qualified specialist personnel or in a workshop approved by the manufacturer. Improper repairs may result in considerable danger for the user.

WARNING! If the mains power cable of this shiatsu cushion is damaged, it has to be replaced by the manufacturer or its service department or a similarly qualified person in order to avoid hazards.

- Before initial use

CAUTION! Remove the transportation lock for the massage mechanism before you start to use the cushion.

To do this, remove the screw using the provided tool on the rear side of the cushion. If this screw of the transportation lock is not removed and the shiatsu cushion is used at once, the cushion will be damaged irreparably and unusable. In this case no warranty will be assumed.

■ Always employ the transportation lock screw for the duration of any further transport in the future. Every transport without a transportation lock can damage the shiatsu cushion irreparably.

● Bringing into service / operation

Note: Only use the shiatsu cushion in an upright position, never lay it flat on the floor.

Note: The zip fastener on the shiatsu cushion may not be opened because it is only there for technical reasons.

Note: The shiatsu cushion may give off an odour of plastic on first use. This odour will cease to develop after a short while.

Note: The shiatsu cushion automatically switches off after 15 minutes. Use the shiatsu cushion for a maximum period of 15 minutes. Longer use may lead to over-stimulation and hence tension in the muscles.

Note: Ensure that you are sitting in the middle of the device and that the massage heads 4 can move to the left and right of your spine.

Note: Do not lie, sit and stand with your full weight on the moving parts of the shiatsu cushion and do not place any objects on the cushion.

- Insert the mains plug into the mains socket. Position the lead to avoid creating a trip hazard.

Switching on / off:

☐ Switch on the shiatsu cushion by pressing the On/Off button 5.

Bringing into service / operation / Troubleshooting / Cleaning and Care

☐ After use, switch off the shiatsu cushion by pressing the On /Off button 5.

Back massage:

☐ Select with button A+B 7, A 8 or B 9 the area you would like to have massaged:

A+B: your whole back

A: upper back

B: lower back.

The LED lamp signalises the massage area that has been set.

Note: When you select the massage area, the automatic switch-off will be activated and set at 15 minutes.

Press the timer button 10, using the appropriate frequency, to set the automatic switch-off at 5, 10, or 15 minutes.

Note: By resetting the timer, the timer will begin counting anew. At the beginning of the massage, select the maximum duration and do not change it during the massage to prevent the shiatsu cushion from overheating.

Note: Ensure that you are experiencing the massage as pleasant and relaxing. If necessary, vary the pressure and/or your position. Stop the massage at once if it is painful or unpleasant.

Heating function:

Press the heat button 6 to activate the heating function. Press the heat button 6 again to deactivate it.

Note: The heating function cannot be activated unless a massage program has been previously selected.

Seat vibration:

Press the seat vibration button 11 to activate the seat vibration. The vibration starts at low intensity and the relevant LED for seat vibration will light up. Press the seat vibration button 11, with the appropriate frequency, to switch to low, medium, or high intensity, or to deactivate the seat vibration.

Note: The seat vibration can be activated together with the back massage. However, the

vibration intensity will be slightly reduced in this case.

Demonstration:

Press the Demo button 12 to have the functions of the shiatsu cushion demonstrated to you.

Troubleshooting

Problem Cause Rectification

Massage heads rotate slower and slower. Too much pressure on massage heads. Relieve pressure on massage heads. Massage heads do not move. Shiatsu cushion is not connected to the mains supply. Insert the plug and switch on the cushion. Shiatsu cushion is not switched on. Switch on the shiatsu cushion by pressing the On/Off button 5. Select the massage area. The transportation lock has not been removed. The massage mechanism is damaged. Contact your specialist dealer or the service address.

Cleaning and Care

SILVERCREST SSMK 40 B2 - Cleaning and Care - 1

SILVERCREST SSMK 40 B2 - Cleaning and Care - 2

WARNING! DANGER TO LIFE BY ELECTRIC SHOCK!

Always disconnect the plug from the mains socket before cleaning the shiatsu seat cushion. Otherwise there is a risk of electric shock.

SILVERCREST SSMK 40 B2 - WARNING! DANGER TO LIFE BY ELECTRIC SHOCK! - 1

SILVERCREST SSMK 40 B2 - WARNING! DANGER TO LIFE BY ELECTRIC SHOCK! - 2

DANGER OF ELECTRIC SHOCK!

Do not pull the cover 2 over the cushion until it is completely dry.

Otherwise there is a risk of electric shock.

SILVERCREST SSMK 40 B2 - DANGER OF ELECTRIC SHOCK! - 1

SILVERCREST SSMK 40 B2 - DANGER OF ELECTRIC SHOCK! - 2

CAUTION! DANGER OF MATERIAL DAMAGE!

Do not use chemical cleaners or scouring agents for

Cleaning and Care/Storage/Disposal/Warranty/Service centre

cleaning the shiatsu cushion. Otherwise you may damage it.

Clean the shiatsu cushion only in the manner indicated. Under no circumstances must any liquid be allowed to enter the shiatsu cushion or the accessories.

Small stains can be removed with a cloth or moist sponge and if necessary with a little mild detergent. Do not use solvent-containing cleaners.

Clean the removable cover 2 in accordance with the cleaning symbols on the label. It is machine-washable. Set the washing machine to a delicate wash cycle at 30 °C.

Use a mild detergent at the dose recommended by the manufacturer.

Note: Non-observance of the following warnings may damage the shiatsu cushion.

Do not use bleach. Do not use any cleaning agents containing bleach (such as heavy duty detergents).

Do not dry in a tumbler dryer.

Do not dry in a tumbler dryer.

Do not dry in a tumbler dryer.

Do not dry in a tumbler dryer.

Do not dry in a tumbler dryer.

Do not iron.

Do not iron.

Do not iron.

Do not iron.

Do not iron.

Storage

RISK OF DAMAGE TO THE PRODUCT OR PROPERTY! Let the shiatsu cushion cool before putting it away. Otherwise material damage could occur.

RISK OF DAMAGE TO THE PRODUCT OR PROPERTY! To prevent the shiatsu cushion from becoming sharply creased, do not place other objects on top of the cushion when it is stored. Otherwise material damage could occur.

If you do not intend to use the shiatsu cushion for any length of time, store it in the original

packing in a dry place without weighing it down.

●Disposal

The packaging and ancillary packing consist of environmentally friendly materials. They can be disposed of at your local recycling facility.

Do not dispose of electrical equipment in the household waste!

In accordance with European Directive 2002 / 96 / EC (covering waste electrical and electronic equipment) and its transposition into national legislation, worn out electrical devices must be collected separately and taken for environmentally compatible recycling.

Contact your local refuse disposal authority for more details of how to dispose of your worn out electrical devices.

● Warranty / Service centre

We provide a 3-year warranty covering faults in materials or manufacture of the shiatsu cushion from the purchase date.

The warranty does not cover:

  • Damage resulting from improper use.
  • For wear parts.
  • For defects that were known to the customer at the time of purchase.
  • Damage for which the customer was responsible.

This warranty does not affect the customer's legal rights.

The customer must provide proof of purchase in order for any warranty claims within the warranty period to be honoured. Claims under the warranty are honoured by

SILVERCREST®

11 GB/IE

Warranty / Service centre / Declaration of conformity

for a period of 3 years after the date of purchase.

In the event of a warranty claim, the customer has the right to have the goods repaired by our own workshop or a workshop authorised by us. The shiatsu cushion must not be opened for any reason. Opening or modifying the cushion invalidates the warranty. This warranty does not grant any additional rights to the customer. Complaints are often initiated by difficulties encountered during use. Many of these complaints can be resolved by telephone or email. Please contact our Service Hotline in the first instance, before you return the shiatsu cushion to the manufacturer.

IAN 75929

GB

∅ 020 30249050

IE

0152 45132

● Declaration of conformity CE

This appliance complies with the requirements of the relevant European and national guidelines. This is confirmed by the CE mark. The relevant declarations are held by the manufacturer.

CE

Introduction

01099 Dresden, Germany