Product TypeDehumidifier
BrandToyotomi
ModelTD-C120
Dimensions (W x D x H)30 cm x 20 cm x 50 cm
Weight12 kg
Power Supply230 V ~ 50 Hz
Power Consumption300 W
Dehumidification Capacity12 L/day (at 30°C, 80% RH)
Water Tank Capacity3.5 L
RefrigerantR-134a
Fan Speeds2 (High/Low)
HumidistatAdjustable (40% - 80% RH)
Automatic DefrostYes
Timer1-12 hours
Air FilterWashable pre-filter
Noise Level48 dB(A)
Operating Temperature Range5°C - 35°C
MaintenanceClean filter every 2 weeks; empty tank regularly
Safety FeaturesOverheat protection, auto shut-off when tank full
Spare Parts AvailableAir filter, water tank, drain hose
Repairability Index7.5 / 10

Frequently Asked Questions - TD-C120 Toyotomi

How do I clean the air filter?
Turn off and unplug the unit. Remove the filter cover, take out the filter, and wash it with warm water and mild detergent. Let it dry completely before reinstalling. Clean every 2 weeks for optimal performance.
What does the 'Full Tank' indicator mean?
It means the water tank is full. Empty the tank through the drain outlet, then replace it securely. The unit will resume operation automatically.
Can I use a continuous drain hose?
Yes. Connect a standard garden hose (1/2 inch) to the drain outlet on the back of the unit. Ensure the hose is positioned downward for gravity drainage.
Why is my dehumidifier not collecting water?
Check if the humidity level is set above the room's humidity. Also ensure the temperature is above 5°C. Clean the air filter and make sure the coils are not frosted (wait for defrost cycle).
How often should I empty the water tank?
It depends on humidity. In high humidity (above 70%), you may need to empty every 4-6 hours. The tank holds 3.5 liters. The unit will shut off automatically when full.
The unit is making a loud noise. What should I do?
Check if the unit is level on a flat surface. Ensure there are no loose objects inside. A slight gurgling sound from the refrigerant is normal. If loud vibrations occur, place a mat underneath.
What is the ideal humidity setting for a bedroom?
For comfort and health, set the humidity between 40% and 50%. Lower settings (30-40%) are for basements or areas with mold issues.
How do I defrost the unit?
The automatic defrost function activates when ice builds up on the coils. The compressor stops and the fan runs until the ice melts. Do not manually scrape ice.
Can I use the dehumidifier in a cold room?
The unit operates in temperatures from 5°C to 35°C. Below 5°C, frost may form and reduce efficiency. The automatic defrost helps, but performance drops below 10°C.
Where can I buy a replacement filter?
Contact Toyotomi customer service or visit authorized parts distributors. Use only genuine Toyotomi TD-C120 filters to ensure proper fit and performance.

User questions about TD-C120 Toyotomi

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Dehumidifier in PDF format for free! Find your manual TD-C120 - Toyotomi and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TD-C120 by Toyotomi.

USER MANUAL TD-C120 Toyotomi

natural_image Line drawing of a portable air purifier device with control panel and ventilation slots (no text or symbols)

TD-C120

TD-C160

COMPRESSOR TYPE DEHUMIDIFIER

DÉSHUMIDIFICATEUR D'AIR

LUFTENTFEUCHTER

LUCHTONTVOCHTIGER

DEUMIDIFICATORE CON

COMPRESSORE

AFFUGTER AF

KOMPRESSORTYPE

OPERATING MANUAL ENGLISH P. 1

MANUEL D'UTILISATION FRANÇAIS P. 5

The idea behind the unit is a localized dehumidification. The unit will greatly enhance your personal comfort whether at a work office, bathroom or even in your favorite closet.

It dries the air so that you can stay comfortable even when it's humid or rainy outside. Also your furnishings, fabrics and clothes are kept in good condition, and it is easy to dry your laundry and dry it quickly.

This unit creates dry air zone anywhere you need it. It means that it does not waste energy drying the surroundings.

It's easy to operate. Once you set your desired level of relative humidity from 60% to 40% , the built-in humidistat allows the room humidity to be controlled automatically.

By connecting the commercially available hose to the unit, you can use it as continuous drainage mode. This is especially convenient for using in the outside such as garage.

OPERATIONAL FEATURES

This unit takes in the humidity and dry air is directed out from the upper louvers by the compressor.

2. AUTOMATIC OPERATION:

Once the desired function has been set, it is memorized as long as it remains connected to the wall outlet. In the event of a power failure, the desired function must be re-entered when power is restored.

3. HUMIDITY CONTROL:

The compressor will automatically shift to ON or OFF to maintain the desired humidity.

4. AUTOMATIC SHUT-OFF MECHANISM WHEN THE DRAIN TANK IS FULL:

When the drain tank is full, the unit will be automatically shut off. The "FULL" lamp will blink. It will resume operation after the condensed water is removed from the tank.

5. AIR FILTER:

A pre-filter protects the unit from dust.

1. DESCRIPTION

Fig. A FRONT

A1 Air outlet

A2 Front panel

A3 Operation panel

A4 Carrying handle

A5 Water tank

A6 Water gauge

Fig. B REAR

B1 Air intake

B2 Air intake grille (Pre-filter)

B3 Power plug storage part (To prevent the plug deformation)

B4 Power supply cord

B5 Power plug

B6 Drain water outlet for continuous drain operation

C3 Full lamp (When the tank filled up with the water, the lamp will light)

C4 Humidity setting button

C5 Cont. lamp (Continue lamp)

C6 40% humidity setting lamp

C7 50% humidity setting lamp

C8 60% humidity setting lamp

Fig. E CONTINUOUS DRAINAGE

E1 Outlet cap

E2 Rubber stopper

E3 Drain water outlet

E4 Drainage hose

2. SAFETY TIPS

IMPORTANT

- Read instructions carefully before operation.

- The unit should be operated when the room temperature is between 5^ to 32^ . If the room temperature is below 5^ , ice may form on the coils. If the room temperature is above 32^ , the compressor will automatically shut off to protect itself.

- ALWAYS, wait 3 min. to restart after turning unit off.

▲WARNING

- NEVER expose infants, handicapped persons, or senior persons directly to the airflow. Adjust the airflow direction.

- Keep children away from unit. Children are particularly liable to this danger. The inside fan is running at high speed. Covering them may deteriorate dehumidifier performance or cause it to become inoperative.

- NEVER insert objects of any kind into the air intake or air outlet.

- DO NOT unplug or plug in if your hands are wet. An electrical shock may occur.

- DO NOT operate in a wet location.

- A LWAYS plug into 220V-240V, 50Hz, single phase electrical outlet.

- Be sure the power plug fits the receptacle securely.

- DO NOT run power cord under carpets, rugs, or floor mats of any kind.

- DO NOT attempt to shorten or alter power cord in any way.

- DO NOT apply any excessive force or pressure to the power supply cord.

- Make sure that the plug is free of dust.

- DO NOT use an extension cord.

- DO NOT use multiple power points.

- DO NOT turn on and off by inserting or removing the power plug, which may cause electric shock or fire.

- If there is a fear of lightning, stop the unit and disconnect the power supply cord.

- DO NOT touch the evaporator, condenser and pipes.

- DO NOT operate with filter removed.

- If the power cord on this unit is damaged, it must be replaced by the manufacture, its service agent or qualified persons in order to avoid a hazard.

- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.

• Children shall not play with the appliance.

- Cleaning and user maintenance shall not be made by children without supervision.

- The appliance shall not be installed in the laundry.

- The appliance shall be installed in accordance with national wiring regulations.

CAUTION

- Keep unit more than 20 cm away on the rear side (F2), 10cm

away on the upper and both side (F1), and 15 cm away on the front side (F3) from any objects or wall. (Fig. F)

  • Remove drain water before moving unit.
  • To minimize corrosion, DO NOT use in damp, salty air area.
  • DO NOT operate in direct sunlight.
  • DO NOT use for such particular purpose as preservation of foodstuff, animals, plants, precision appliances, arts and medicine.

- DO NOT place an animal, plants or combustion equipment in a place which is subjected to the direct air flow of the unit.

- DO NOT ride or place the objects on the unit.

- DO NOT turn the product on its side or upside down.

- DO NOT remove the rubber cap cover of water drainage outlet except in continuous drainage mode to avoid water leakage.

Toyotomi TD-C120 - CAUTION - 1

- Waste electrical products should not be disposed with household waste.

- Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.

3. OPERATION

OPERATING STEPS:

1. CONNECT POWER PLUG (B5) TO POWER SOCKET.

Make sure the water tank (A5) is placed in proper position, and then connect to the power socket.

If the tank is not in proper position, the FULL lamp (C3) will light after plug on. If FULL lamp lights at the first time, please pull out the tank once and push it back to the proper position.

2. PRESS POWER BUTTON (C1) TO ON.

3. PRESS HUMIDITY SETTING BUTTON (C4)

Press the humidity setting button (C4) to select your desired humidity mode.

By pressing the humidity setting button, indication lamp will shift to; “CONTINUE” (C5) → “60%” (C8) → “50%” (C7) → “40%” (C6) → CONTINUE” (C5) and your desired humidity mode can be selected.

4. EMPTY THE WATER TANK (Fig.D)

1. Stop the operation.

NOTE: When the water tank is full, the Full lamp (C3) will blink and unit stops automatically in a few minutes.

2. Remove the water tank. (Fig. D1)

NOTE: Do not move the unit or remove the water tank, if the machine is still operating, as water may leak, damage the unit or cause an electric shock.

Do not remove or damage the float in the water tank, or the unit cannot work correctly.

3. Pour water away. (Fig. D2)

4. Restore the water tank to the correct position.

NOTE: If the water tank is not well in the position, the Full lamp (C3) will blink.

5. CONTINUOUS DRAINAGE WATER (Fig. E)

  1. Prepare a hose that is inner diameter of 13mm or 15mm, and take out the outlet cap (E1).
  2. Remove the rubber stopper (E2) inside the outlet cap (E1). Then you can see the hole. (Fig. E5)

  3. Put the hose (E4) into the drain water outlet (E3). (Fig. E6)

NOTE:

  • In case of using the hose of inner diameter of 15mm, insert the hose to the drain water outlet all the end. (E7)
  • In case of using the hose of inner diameter of 13mm, put the hose into the tip of drain water outlet (E8)

- During the continuous drainage mode, the drain hose must be horizontally or below the drainage hole (E9), and try not to raise the hose above the drainage hole (E10) or fold the hose (E11).

6. CLEANING

CLEANING AIR INTAKE FILTER (Fig. G)

  1. Clean the air intake once every two weeks.
  2. To remove the outside air intake filter (Fig. G1) pull the filter off by pushing the two hooked part which are upper the filter.
  3. Remove the dust with a vacuum cleaner. (Fig. G2), or wash the dust away with water. If you wash it with water, dry it in the shade after washing it.

WARNING

- DO NOT touch the evaporator. It may cause injury or damage.

CAUTION

  • DO NOT use over 40^ hot water. The plastic part may be deformed.
  • Disconnect the power supply before cleaning and maintenance.

CLEANING SURFACE

Clean the outside of the product with a soft damp cloth.

CAUTION

- NEVER use gasoline, solvents, chemical, products or polish as they could damage the surface.

7. LONG-TERM STORAGE

At the end of each season, or when you do not plan to use this product for an extended period of time, the following procedures are recommended.

  1. Empty the water tank.
    After stopping operation, leave it for one day and empty the water tank.
  2. Take off the outlet cap (E1) and rubber stopper (E2) which is for continuous drainage.
    When you take the rubber stopper (E2) off, the drain water will come out. Therefore receive the water with a bucket or a tank.

  3. Clean the unit, tank and filter.

Wipe off any dirt or dust on the unit with a soft damp cloth or a vacuum cleaner, and then wipe again using a soft dry cloth.

  1. Store the unit.

The original shipping carton is the best place to store your unit. If you do not have the original packing materials, cover the unit with a large plastic bag and store in a cool dry place.

CAUTION

  • ALWAYS store the unit at less humidity and airy place with standing vertically.
  • DO NOT put heavy objects on top of the unit.

8. TRANSPORTATION

Preferably keep the unit in the vertical position during transportation. If it is necessary to place the unit in a horizontal position more than 1/2 hour, ALLOW IT TO REMAIN UPRIGHT FOR 24 HOURS BEFORE OPERATION. Failure to do so may result in damage to the compressor. Before transporting / moving the unit make sure the drain tank is empty.

  1. TROUBLESHOOTING
SYMPTOMCAUSESOLUTION
Unit does not work.- Power cut.- The plug has been plugged improperly.- The FULL LAMP is ON. Tank is full.- The DEFROST LAMP is ON.- Wait for power to be supplied again.- Plug in again.- Remove the drain water from the drain tank.- When the room temperature is under 12°C, the heat exchanger is sometimes frosted. And the unit starts defrosting mode automatically. During this mode, DEFROST LAMP is ON, and waits for a while.
FULL lamp is ON even the water tank is empty.- The tank is not inserted properly.- The float of tank is not placed properly.- Take the water tank out once, and push it back to the proper position.-Place the float in the proper position.
The product does not de-humidify.- The filter is dusty or air outlet is clogged.- Surrounding temperature and humidity are low.- Clean the filter and air outlet.- As the temperature and humidity are lower, the amount of de-humidification is also lower.
Operation sound is loud.- The filter is dusty- The unit operates on the rough place.-Clean the filter.-Operate at the flat place.
The drain water is leaked.- The unit leans.- Move the unit with water in the tank.- The float is not in the proper position.- Take the water tank out soon after stopping the operation.- Operate at the flat place.- Remove the water at first, and then you can move the product.- Place the float properly.- The product keeps draining even the unit stops operating. Wait for approx. 5mins.

BEFORE CALLING FOR SERVICE
The following are not defects.

A hissing noise or hollow sound: This sound is generated from the refrigerant flowing within pipes.
A squeaking noise: This noise is generated from the unit when it is expands or contracts with temperature changes.
Odor: Such odor as tobacco, cosmetics, or foods may accumulate in the unit.
The unit does not start nor change operation mode immediately: To prevent overloading the compressor motor, the unit will be stopped for more than 3 minutes.
  1. SPECIFICATIONS
MODEL TD-C120 TD-C160
DEHUMIDIFYING CAPACITY12 L/D 16 L/D(30°C, 80%RH) (30°C, 80%RH)
POWER SOURCESingle Phase Single Phase220-240V, 50Hz 220-240V, 50Hz
POWER CONSUMPTION 195W 265W
OPERATING CURRENT 0.74A1.1A
AIR FLOW (MAX.) 72 m ^3/h 72 m ^3/h
OPERATING TEMP. RANGE 5/ HUMIDITY / 30% - 80%RH°C ~ 32°C
DIMENSIONS (WxHxD) 303 x468 x 193 mm
WEIGHT 8.9kg 9.2kg
COMPRESSORROTARYROTARY
REFRIGERANTR-134A / 90gR-134A / 110g
FUSE3.15A/250V (Type: 3N, 3K, 30T)
GWP1300 (R134a)
WIRING DIAGRAMToyotomi TD-C120 - TRANSPORTATION - 1

NOTE: Dehumidifying capacity will vary according to temperature and humidity of the room.

CONTAINS FLUORINATED GREENHOUSE GASES COVERED BY THE KYOTO PROTOCOL.

HERMETICALLY SEALED SYSTEM

GWP information (according to (EC) No 842 / 2006

LIMITED WARRANTY

TOYOTOMI CO., LTD. ("TOYOTOMI") warrants each product and any parts thereof sold by it to be free from defects in materials or workmanship under normal use and service for TWENTY FOUR (24) MONTHS from the date of delivery to the original purchaser at retail subject to the following terms and conditions:

WHAT IS COVERED: Product or any parts thereof which are defective in materials or workmanship.

WHAT IS NOT COVERED:

This warranty does not extend to any defect due to the negligence of others; failure to install, operate or maintain unit in accordance with instructions (operating and maintenance instructions are furnished with each new unit); unreasonable use, accidents, alteration, use of unauthorized or non-standardized TOYOTOMI parts and accessories; electrical malfunction, i.e., as resulting from large power surges, short circuit, etc.; incorrect installation; or repair by anyone other than a service facility specified by TOYOTOMI.

WHO IS COVERED: The original purchaser at retail.

WHAT WE WILL DO: TOYOTOMI will either repair or replace, at its opinion, all defective parts free of charge that are covered by this limited warranty on a carry-in basis, to your nearest authorized dealer or distributor of TOYOTOMI.

WHAT YOU MUST DO FOR WARRANTY SERVICE: You must return the defective Product or part to any authorized dealer or distributor of TOYOTOMI with this LIMITED WARRANTY. If service is not available locally, please contact our CUSTOMER RELATIONS DEPARTMENT at:

TOYOTOMI EUROPE SALES B.V.

E-MAIL: info@toyotomi.eu

INTERNET: www.toyotomi.eu

THE FOREGOING EXPRESS ALL OF TOYOTOMI'S OBLIGATIONS AND LIABILITIES WITH RESPECT TO THE QUALITY OF PRODUCT FURNISHED BY IT. ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FIFTNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. TOYOTOMI SHALL NOT BE LIABLE FOR THE LOSS OF USE OF THE PRODUCT, INCONVENIENCE, LOSS OR ANY OTHER DAMAGES, DIRECT OR CONSEQUENTIAL ARISING OUT OF, THE USE OF, OR INABILITY TO USE, THE PRODUCT OR DAMAGES RESULTING FROM OR ATTRIBUTABLE TO DEFECTS IN THE PRODUCT.

No other than TOYOTOMI has authority to extend or modify the terms of this Limited Warranty in any manner whatsoever.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so these limitations or exclusions may not apply to you. This Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state.

TOYOTOMI CO., LTD.

5-17, Momozono-cho, Mizuho-ku,

Nagoya, 467-0855 Japan

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Toyotomi

Model : TD-C120

Category : Dehumidifier