Product TypeDigital Kitchen Scale
BrandScarlett
ModelSC-219
Dimensions (W x D x H)20 x 15 x 2 cm
Weight300 g
Power Supply2 x AAA batteries (not included)
Maximum Capacity5 kg
Accuracy1 g
DisplayLCD, 4 digits
Platform MaterialStainless steel
Measurement Unitsg, oz, lb:oz
FunctionsTare, auto power-off, low battery indicator
Auto-Off Time60 seconds of inactivity
CleaningWipe with a damp cloth; do not immerse
Operating Temperature10°C to 40°C
Safety FeaturesOverload protection, non-slip feet
Spare PartsBatteries only (user-replaceable)
ReparabilityNot repairable by user; contact service center
CertificationsCE, RoHS

Frequently Asked Questions - SC-219 Scarlett

How do I change the batteries?
Open the battery compartment on the bottom, remove old batteries, and insert two new AAA batteries with correct polarity. Close the compartment securely.
How do I clean the scale?
Wipe the surface with a soft, damp cloth. Do not use abrasive cleaners or immerse the scale in water. Dry thoroughly before storing.
What is the maximum weight limit?
The maximum capacity is 5 kg (11 lb). Do not exceed this limit to avoid damage.
How accurate is the scale?
The scale has an accuracy of 1 g (0.05 oz) for weights up to 5 kg.
What measurement units are available?
You can switch between grams (g), ounces (oz), and pounds:ounces (lb:oz) by pressing the UNIT button.
How does the tare function work?
Place an empty container on the scale and press the TARE button to reset the display to zero. Then add ingredients; the display shows only their weight.
Why won't my scale turn on?
Ensure batteries are installed correctly and have sufficient charge. If the display remains blank, try replacing the batteries. Also check for any debris on the contacts.
Is the scale waterproof?
No, the scale is not waterproof. Avoid exposure to water or liquids. Clean with a damp cloth only and keep away from moisture.
How long before auto shut-off?
The scale automatically turns off after 60 seconds of inactivity to save battery life.
What is the warranty period?
Scarlett offers a 2-year warranty against manufacturing defects. Retain proof of purchase and contact authorized service centers for support.

User questions about SC-219 Scarlett

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Scale in PDF format for free! Find your manual SC-219 - Scarlett and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SC-219 by Scarlett.

USER MANUAL SC-219 Scarlett

  1. Body
  2. Display
  3. Switch of metages
  4. Control panel
  5. Electrodes

CZ POPIS

  • To avoid breakdown during use read this guide carefully before operating the appliance. Mishandling can cause breakdown of the appliance.
  • Only for domestic use. The appliance is not designed for industrial or commercial use.
  • Do not expose the scale to shocking.
  • Do not jump on the scale.
  • Do not overload the scale.
  • It is forbidden for use by persons with medical implants (for example, with pacemakers). Otherwise, faulty operation of implants might occur.
  • Do not use during pregnancy.
  • Attention! Do not step on the scale if your feet or the scale surface are wet – you might slip.
  • Batteries may be life-threatening if swallowed.
  • Store the batteries and the scale out of the reach of children. The person who swallowed a battery, should immediately consult a doctor.
  • Do not allow wrapping material getting into the hands of children (choking hazard).
  • It is forbidden to recharge or restore batteries in other manner, disassemble them, or throw into fire.
  • Measuring body fat percentage and other parameters in children below 10 years of age may yield invalid results.
  • Diagnostic scale may be used for simple weighing without determining water, body fat or muscle mass parameters in children of any age. Minimum weighing limit is 2 kg.
  • Unreliable results of measuring body water, body fat or muscle mass might occur in professional athletes, persons prone to oedema, persons with irregular leg-to-body ratio.
  • If the product has been exposed to temperatures below 0^ C for some time it should be kept at room temperature for at least 2 hours before turning it on.
  • The manufacturer shall reserve the right to introduce minor changes into the design of the scale, which do not affect its safety, performance capacity or functionality of the appliance.

WEIGHING

- The principle behind this scale is bioelectrical impedance analysis (B.I.A.). The measurement of the percentage of different tissues occurs within seconds with electric current, which is not perceptible for a human, safe and harmless.

- It is important that during measurement you take into account the following: measurement of the body fat percentage must be performed only barefoot; it is advisable that you slightly moisturize the soles of your feet. Absolutely dry soles might be the cause of an unsatisfactory result, as they possess extremely low electric conductivity.

- If, when measuring the percentage of fat, muscle tissue, bone and water content, the obtained sum of all components has become greater than 100%, this is not a sign of scale defect. It can be explained from the physiological point of view. Operation of the diagnostic scale is based on the analysis of bioimpedance, which determines the amount of fat and water in muscle and bone tissues themselves. Thus the variation of different parameters should be taken into account separately from each other, without summarizing the obtained results.

WEIGHING

  • Make sure the scale stands on a flat, even and firm level surface. Do not put the scale onto a carpet or soft surfaces.
  • To ensure correct weight measurement it is advisable that the scale stand in the same place. By moving the scale you risk putting it on an uneven surface, which might affect the correctness of your weight reading.
  • To ensure correct weight measurement you need to weigh at the same time, without clothes or footwear, and before eating.
    • To ensure precise weight measurement it is not recommended to weigh earlier than 2 hours after waking.
  • Step on the scale. Do not lean against anything, stand straight.

GETTING STARTED

  • Insert type AAA batteries observing polarity into a special compartment at the bottom of the scale. Close the compartment. The scale is ready to operate.
  • By default the scale is set to stones. There is a switch on the rear panel of the scale, for selecting “kilos” or “pounds” as units of measurement.
  • Step on the scale to switch it on.
  • Wait for some seconds until "0.0" is displayed.

AUTOMATIC SHUTDOWN

  • If nothing happens within 20 seconds after switching on the scale will shut down automatically.
  • After weighing the scale shuts down automatically in 6 seconds without load.

SETUP OF USER DATA

- You should first set your parameters to perform the analysis.

- Push the SET button, the first storage location out of nine (USER0) will light up on the display. You can set the following:

Display readingMeaning
Male
Female
CM(FT;In)Height
AgeAge
FATFat
TBWWater
MUSMuscle mass
BONEBone weight
%Percentage ratio

ENTERING PERSONAL DATA

  • You can set respective values by pushing "up" and "down" ▼ buttons. You should confirm each entered value by pushing the SET button.
  • Push the SET button. A free storage location will light up on the display – a user name, for example, USER 01.
    Confirm the choice by pushing the SET button or select another free user by pushing buttons ▲ for instance, USER 02. Push SET to change to other settings.
  • Then a symbol “a man” 🚙 or “a woman” 🚙 will light up. Confirm your choice by pushing the SET button or select your sex by pushing ▲ buttons.
  • Push SET to change to other settings.
  • Similarly specify age (age) and height (cm) parameters.
  • To confirm each parameter push the SET button.
  • After confirming the last parameter (height, cm) The display will show 0.0 KG and user name, for example, USER 2. Begin weighing. Stand still during weighing until the reading settles.
  • Attention: during measurement there must be no contact between both feet, calves, shanks or thighs. Otherwise, the measurement cannot be performed properly.
  • First the display will show your weight, then in some seconds you will see the following information on the display, which will appear one by one:
Display readingMeaning
FATFat
TBWWater
MUSMuscle mass
BONEBone weight
%Percentage ratio

- The data inform how fit you are at the moment (see the table).

AgeWomenMen
Body fatBody waterBody fatBody waterAmount of fatDisplay
≤304.0-20.566.0-54.74.0-15.566.0-58.1Underweight-
20.6-25.054.6-57.615.6-20.058.0-55.0Normal0
25.1-30.551.5-47.820.1-24.554.9-51.9Overweight+
30.6-50.047.7-34.424.6-50.051.8-34.4Obese++
>304.0-25.066.0-51.64.0-19.566.0-55.4Underweight-
25.1-30.051.5-48.119.6-24.055.3-52.3Normal0
30.1-35.048.0-44.724.1-28.552.2-49.2Overweight+
30.1-50.044.6-34.428.6-50.049.1-34.4Normal++

MESSAGES ON THE DISPLAY

- ATTENTION: If an error message is displayed, wait until the appliance shuts down. Switch it on again to restart the operation. If the error message does not disappear remove batteries from the battery compartment for 10 seconds, after that insert them again and switch on the appliance.

IndicatorsMeaning
8888Selection of the user and personal parameters
0000Analysis of readings after weighing.
----- Improper positioning of the scale. Place the scale on a flat, firm surface.- You are standing on the scale with your footwear on.Take off your footwear and step on the scale again.
LOIndication of the low battery charge. The batteries are discharged, please, replace them with new ones.
ErrHIndication of the high % of body fat. Body fat percentage is too high. Recommendations: you should keep to a low-calorie diet, do more exercise and pay more attention to your health.
ErrlIndication of the low % of body fat. Body fat percentage is too low. Recommendations: you should keep to a more nourishing diet and pay more attention to your health.
EEEEIndication of overload. The weight exceeds maximum permissible value for measurement. Please, step off the platform to avoid damage to the scale.

CLEANING AND MAINTENANCE

  • Wipe the scale with a soft cloth using a detergent and wipe dry.
  • Do not use organic solvents, aggressive chemicals or abrasives.

STORAGE

  • Observe all requirements from the CLEANING AND MAINTENANCE Section.
  • Make sure there are no objects on the scale during storage.
  • Store the scale in a cool dry place.